AEM
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cook, A. M.
Right arrow Articles by Berry, R. J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Cook, A. M.
Right arrow Articles by Berry, R. J.
Agricola
Right arrow Articles by Cook, A. M.
Right arrow Articles by Berry, R. J.

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1968 August; 16(8): 1156-1162
Copyright © 1968 American Society for Microbiology. All Rights Reserved.

Microbial Contamination on Disposable Hypodermic Syringes Prior to Sterilization by Ionizing Radiation1

A. M. Cook and R. J. Berry

Welsh School of Pharmacy, University of Wales Institute of Science and Technology, Cardiff, Wales
Radiobiology Laboratory, Churchill Hospital, Oxford, England

ABSTRACT

A large number of syringes were taken from the production lines of three independent manufacturers; the numbers and types of microorganisms contaminating these randomly sampled syringes were assessed in the laboratories maintained by each of these manufacturers for routine sterility testing, according to a standard protocol devised by the Research Committee of the UK Panel on Gamma and Electron Irradiation, which coordinated the investigation and analyzed the results. Items produced by a manufacturer were assessed for microbiological contamination both in their own laboratories and in the laboratories of the other manufacturers. The level of "false-positive" results was determined independently for each laboratory by the testing of "known sterile" items which had been subjected to the radiation-sterilization process. Both the percentage of syringes initially sterile and the average number of organisms per contaminated syringe differed among the three manufacturers. When corrected for interlaboratory differences, the number of syringes initially sterile ranged from 16 to 48%, and the mean number of organisms per contaminated syringe was 20 to 70. Of 964 syringes tested by all three laboratories, only one contained over 1,000 aerobic organisms (1,133). The most common organisms found were coagulase-negative, gram-positive cocci. Two manufacturers assessed contamination by anaerobic organisms; of 610 syringes, 1 contained 4,275 organisms and 3 more had 100 to 1,000 organisms, but 488 (80%) were uncontaminated by anaerobes. The results are discussed in the context of the choice of radiation dose necessary for the sterilization of medical products manufactured under controlled hygienic conditions.


FOOTNOTES

1 A publication of the Research Committee of the UK Panel of Gamma and Electron Irradiation. Members of the Committee are as follows: A. M. Cook (Chairman), R. J. Berry (Technical Secretary), R. W. H. Cook, C. G. Crawford, J. F. B. Dealler, J. O. Dawson, R. S. M. Frohnsdorff, G. E. Gale, J. C. Kelsey, F. J. Ley, P. J. Lindop, and K. Tattersall. The manufacturers paricipating in this study (who are all Full Members of the UK Panel on Gamma and Electron Irradiation) were Gillette Surgical Ltd., Reading, Berks.; Johnson and Johnson (Great Britain) Ltd., Slough, Bucks.; and Smith and Nephew Research Ltd., Harlow, Essex.


Appl Environ Microbiol. 1968 August; 16(8): 1156-1162
Copyright © 1968 American Society for Microbiology. All Rights Reserved.







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
J. Bacteriol. Microbiol. Mol. Biol. Rev. Eukaryot. Cell All ASM Journals

Copyright © 1968 by the American Society for Microbiology. All rights reserved.