AEM
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Österberg, B. O.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Österberg, B. O.
Agricola
Right arrow Articles by Österberg, B. O.

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1973 September; 26(3): 354-358
Copyright © 1973 American Society for Microbiology. All Rights Reserved.

Microbiological Evaluation of Suture Items Before Radiation Sterilization

Bertil O. Österberg

1 Biological Laboratory, Johnson & Johnson AB, S-191 84 Sollentuna, Sweden

ABSTRACT

Microbiological contamination levels of suture samples taken at various stages of the manufacturing process in a new hygienically controlled plant were determined by employing a membrane filturation technique. Both raw material and materials handled manually in the production process were tested to assess the effect of manual handling on the product contamination level. Evaluation of the efficacy of contamination control, however, was directed primarily to the finished, packaged products, just prior to the processing with cobalt 60. The suture material for testing was divided into two groups, namely, wet and dry products, the wet being packaged in a special "tubing" fluid consisting mainly of isopropyl alcohol. Initial contamination results are reported as the average of values obtained on the test day and the preceding 9 consecutive production days. A total of 1,787 suture samples tested in the dry group showed daily averages varying between 2.1 and 14.8 contaminants per suture. The 2,980 wet-packaged suture samples tested gave daily averages varying from 0.7 to 4.2 contaminants per suture. The highest values obtained for an individual suture were 400 for the dry and 89 for the wet. Identification studies of the contaminants revealed that fungi predominated. Most of the bacterial contaminants proved to be spore-forming rods.


Appl Environ Microbiol. 1973 September; 26(3): 354-358
Copyright © 1973 American Society for Microbiology. All Rights Reserved.







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
J. Bacteriol. Microbiol. Mol. Biol. Rev. Eukaryot. Cell All ASM Journals

Copyright © 1973 by the American Society for Microbiology. All rights reserved.