AEM
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jakubowski, W.
Right arrow Articles by Clarke, N. A.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Jakubowski, W.
Right arrow Articles by Clarke, N. A.
Agricola
Right arrow Articles by Jakubowski, W.
Right arrow Articles by Clarke, N. A.

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1975 July; 30(1): 58-65
Copyright © 1975 American Society for Microbiology. All Rights Reserved.

Comparative Study of Four Microporous Filters for Concentrating Viruses from Drinking Water

Walter Jakubowski, William F. Hill Jr. and Norman A. Clarke

Health Effects Research Laboratory, U.S. Environmental Protection Agency, Cincinnati, Ohio 45268

ABSTRACT

Four microporous virus-adsorbent filter media for recovering low levels of virus from 380 liters of drinking water were compared. In addition, two of the filter media were compared with 1,900 liters of drinking water. The filter media evaluated were MF nitrocellulose membranes (293 mm), AA Cox M-780 epoxy-fiberglass-asbestos disks (267 mm), K-27 yarn-wound fiberglass cartridges + AA Cox M-780 disks (127 mm), and Balston epoxy-fiberglass tubes (24.5 by 63.5 mm). The filters were used to concentrate seeded poliovirus from 380 liters of finished drinking water. Sodium thiosulfate was added to the drinking water to neutralize chlorine, and hydrochloric acid was added to adjust the pH to 3.5. Virus was eluted from the filters with glycine-NaOH buffer at pH 11.5. In terms of virus recovery efficiency, the filter media ranked Balston > Cox 267-mm > MF 293-mm ~= K-27 + Cox 127-mm, but differences were slight. The Balston filters and holders were also superior to the other systems in terms of size, weight, cost, and handling factors. Experiments with 2- and 8-µm porosity Balston filters showed no statistically significant difference in virus recovery. Virus was readily detected by the Balston and the MF 293-mm systems at input levels of 12 to 22 PFU/1,900 liters. Preliminary experiments indicated that an elution pH lower than 11.5 may be satisfactory.


Appl Environ Microbiol. 1975 July; 30(1): 58-65
Copyright © 1975 American Society for Microbiology. All Rights Reserved.