AEM
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barbeito, M S
Right arrow Articles by Brookey, E A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Barbeito, M S
Right arrow Articles by Brookey, E A, Jr
Agricola
Right arrow Articles by Barbeito, M S
Right arrow Articles by Brookey, E A

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1976 November; 32(5): 671-678

Microbiological hazard from the exhaust of a high-vacuum sterilizer.

M S Barbeito and E A Brookey Jr

ABSTRACT

Data are presented which show the potential for release of viable microorganisms into the atmosphere from high-vacuum steam sterilizers during the evacuation cycle preceding application of steam under pressure. Bacillus subtilis var. niger spores, Serratia marcescens cells, and T1 coliphage disseminated into the sterilizer chamber as small particles from liquid suspensions, and dried spores of B. subtilis var. niger distributed on bulk discard materials were recovered from the atmosphere around pipes venting steam from the steam ejectors used to create chamber vacuum. Evaluation of the hazard involved is discussed, and the design, fabrication, and installation of a valved filter system for preventing release of viable microorganisms are presented. The filtration system utilized an F-700 water-resistant filter and was shown to eliminate the release of viable airborne microorganisms from a high-vacuum sterilizer. A method is presented for determining size requirements for an atmospheric vent filter in relation to the volume of a sterilizer.


Appl Environ Microbiol. 1976 November; 32(5): 671-678




This article has been cited by other articles:




Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
J. Bacteriol. Microbiol. Mol. Biol. Rev. Eukaryot. Cell All ASM Journals

Copyright © 1976 by the American Society for Microbiology. All rights reserved.