AEM
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Orth, D S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Orth, D S
Agricola
Right arrow Articles by Orth, D S

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1977 December; 34(6): 710-714

Statistical analysis and quality control in radioimmunoassays for staphylococcal enterotoxins A, B, and C.

D S Orth

ABSTRACT

The objective of these studies was to set up a reliable radioimmunoassay (RIA) for staphylococcal enterotoxins A, B, and C (SEA, SEB, and SEC) in a food system. Significant differences (95% confidence limits) were obtained between the 0- and 1-ng/ml enterotoxin standards, so the sensitivity of the RIAs was 1 ng/ml. Polystyrene tubes coated with anti-SEB and stored at 4 degrees C were unstable. The percentage of iodinated SEB bound to these tubes decreased at a rate of 0.33%/day, in contrast to the rate of 0.07%/day obtained with tubes prepared the day before the analyses. Satisfactory precision and maximum sensitivity were obtained by using six replicates for each sample and freshly coated tubes. The antisera used for coating the tubes were reused four times and were frozen between coatings. The process of drum drying mashed potatoes containing 1 mug of SEB per g of mashed potatoes inactivated 83% (wt/wt) of the SEB. Statistical quality control parameters were used to insure that RIAs were performing reliably with a sensitivity of 1 ng/ml. Over 450 samples of potato flakes and granules, which represented different production lots from 12 different manufacturers, were examined for SEA, SEB, and SEC. No enterotoxins were detected.


Appl Environ Microbiol. 1977 December; 34(6): 710-714







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
J. Bacteriol. Microbiol. Mol. Biol. Rev. Eukaryot. Cell All ASM Journals

Copyright © 1977 by the American Society for Microbiology. All rights reserved.