Previous Article | Next Article ![]()
Appl Environ Microbiol. 1979 September; 38(3): 466-470
ABSTRACT
The evaluation of an improved wipe-rinse technique for the bioassay of large areas was undertaken due to inherent inadequacies in the cotton swab-rinse technique to which assay of spacecraft is currently restricted. Four types of contamination control cloths were initially tested. A polyester-bonded cloth (PBC) was selected for further evaluation because of its superior efficiency and handling characteristics. Results from comparative tests with PBC and cotton swabs on simulated spacecraft surfaces indicated a significantly higher recovery efficiency for the PBC than for the cotton (90.4 versus 75.2%). Of the sampling areas sites studied, PBC was found to be most effective on surface areas not exceeding 0.74 m2 (8.0 feet 2).
This article has been cited by other articles:
| J. Bacteriol. | Microbiol. Mol. Biol. Rev. | Eukaryot. Cell | All ASM Journals |
|---|