AEM
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mathewson, J J
Right arrow Articles by DuPont, H L
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mathewson, J J
Right arrow Articles by DuPont, H L
Agricola
Right arrow Articles by Mathewson, J J
Right arrow Articles by DuPont, H L

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1983 November; 46(5): 985-987

Evaluation of filters for recovery of Campylobacter jejuni from water.

J J Mathewson, B H Keswick and H L DuPont

ABSTRACT

Campylobacter jejuni has been incriminated in several large waterborne outbreaks, but it has rarely been isolated from water itself. Better methodology is needed for the isolation of C. jejuni from water. We evaluated three types of 0.45-micron microporous filters and three different pore sizes of positively charged depth filters for their ability to recover C. jejuni from seeded, sterile tap and surface water. The microporous filters tested were Millipore HA, Gelman GN6, and Zetapor. Three pore sizes of Zeta Plus depth filters (05S, 30S, and 50S) were evaluated by using an adsorption-elution technique. The overall percent recovery in both tap and surface water by microporous filters was: Zetapor, 66%; Millipore HA, 33%; and Gelman GN6, 33%. Adsorption-elution with Zeta Plus 50S allowed 89% recovery of C. jejuni. These data suggest that both the positively charged Zetapor microporous filter and the Zeta Plus 50S depth filter are effective filters for the recovery of C. jejuni from water.


Appl Environ Microbiol. 1983 November; 46(5): 985-987