This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ijaz, M K
Right arrow Articles by Springthorpe, V S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ijaz, M K
Right arrow Articles by Springthorpe, V S
Agricola
Right arrow Articles by Ijaz, M K
Right arrow Articles by Springthorpe, V S

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1985 February; 49(2): 289-293

Comparison of the airborne survival of calf rotavirus and poliovirus type 1 (Sabin) aerosolized as a mixture.

M K Ijaz, S A Sattar, C M Johnson-Lussenburg and V S Springthorpe

ABSTRACT

A mixture of a cell culture-adapted strain (C-486) of calf rotavirus and poliovirus type 1 (Sabin) was prepared in tryptose phosphate broth containing 0.1% uranine (physical tracer) and antifoam at a final concentration of 0.001%. By using a six-jet Collison nebulizer, the mixture was aerosolized into a 300-liter stainless-steel rotating (4 rpm) drum. The temperature of the air inside the drum was kept at 20 +/- 1 degrees C, and the virus aerosols were held at the following three levels of relative humidity (RH): low (30 +/- 5%), medium (50 +/- 5%), and high (80 +/- 5%). An all-glass impinger, containing 10.0 ml of tryptose phosphate broth with antifoam, was used to collect samples of air from the drum. Both viruses were propagated and quantitated in MA-104 cells. The calf rotavirus was found to survive well at mid-range RH, where 60% of the infectious virus could be detected even after 24 h of virus aerosolization. At the low RH, the half-life of the infectious rotavirus was ca. 14 h. On the other hand, no infectious poliovirus could be recovered from the drum air at the low and medium RH. At the high RH, more than 50% of the infectious rotavirus became undetectable within 90 min of aerosolization. In contrast to this, the half-life of the poliovirus at the high RH was about 10 h. These data, based on the aerosolization of virus mixtures, therefore suggest that there is a pronounced difference in the way RH influences the airborne survival of these two types of viruses held under identical experimental conditions.


Appl Environ Microbiol. 1985 February; 49(2): 289-293




This article has been cited by other articles:

  • Verreault, D., Moineau, S., Duchaine, C. (2008). Methods for Sampling of Airborne Viruses. Microbiol. Mol. Biol. Rev. 72: 413-444 [Abstract] [Full Text]