AEM
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sobsey, M D
Right arrow Articles by Cromeans, T
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sobsey, M D
Right arrow Articles by Cromeans, T
Agricola
Right arrow Articles by Sobsey, M D
Right arrow Articles by Cromeans, T

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1985 April; 49(4): 795-798

Effects of bentonite clay solids on poliovirus concentration from water by microporous filter methods.

M D Sobsey and T Cromeans

ABSTRACT

To determine whether suspended solids interfere with enteric virus recovery from water by microporous filter methods, the effects of bentonite clay solids at a concentration of 10 nephelometric turbidity units on the recovery of poliovirus type 1 from seeded, activated carbon-treated, filtered tap water were studied. Volumes (500 ml) of virus-laden water at pH 5.5 or 7.5, with and without 50 mM MgCl2, were filtered through 47-mm-diameter, electropositive (Virosorb 1MDS) and electronegative (Filterite) filters that had been pretreated with Tween 80 to minimize direct virus adsorption to filter surfaces. Bentonite solids enhanced virus retention on both types of filters, even under conditions in which viruses were not solids associated. However, bentonite solids also interfered with elution of retained viruses when eluting with 0.3% beef extract-50 mM glycine (pH 9.5). Under some conditions, overall virus recoveries were lower from water with bentonite solids than from solids-free control water. The results of this study indicate that clay turbidity can interfere somewhat with virus recovery by current microporous filter methods.


Appl Environ Microbiol. 1985 April; 49(4): 795-798







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
J. Bacteriol. Microbiol. Mol. Biol. Rev. Eukaryot. Cell All ASM Journals

Copyright © 1985 by the American Society for Microbiology. All rights reserved.