This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fannin, K F
Right arrow Articles by Jakubowski, W
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fannin, K F
Right arrow Articles by Jakubowski, W
Agricola
Right arrow Articles by Fannin, K F
Right arrow Articles by Jakubowski, W

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1985 May; 49(5): 1191-1196

Effect of an activated sludge wastewater treatment plant on ambient air densities of aerosols containing bacteria and viruses.

K F Fannin, S C Vana and W Jakubowski

ABSTRACT

Bacteria- and virus-containing aerosols were studied during the late summer and fall seasons in a midwestern suburb of the United States before and during the start-up and operation of an unenclosed activated sludge wastewater treatment plant. The study showed that the air in this suburban area contained low-level densities of indicator microorganisms. After the plant began operating, the densities of total aerobic bacteria-containing particles, standard plate count bacteria, total coliforms, fecal coliforms, fecal streptococci, and coliphages increased significantly in the air within the perimeter of the plant. Before plant operations, bacteria were detected from five genera, Klebsiella, Enterobacter, Serratia, Salmonella, and Aeromonas. During plant operations, the number of genera identified increased to 11. In addition to those genera found before plant operations, Escherichia, Providencia, Citrobacter, Acinetobacter, Pasteurella, and Proteus, were also identified. Enteric viruses were detected in low densities from the air emissions of this plant. Only standard plate count bacteria remained at significantly higher than base-line densities beyond 250 m downwind from the center of the aeration tanks. Fecal streptococci and coliphages appeared to be more stable in aerosols than the other indicator microorganisms studied. In general, the densities of microorganism-containing aerosols were higher at night than during the day. The techniques used in this study may be employed to establish microorganism-containing aerosol exposure during epidemiological investigations.


Appl Environ Microbiol. 1985 May; 49(5): 1191-1196




This article has been cited by other articles:

  • Baertsch, C., Paez-Rubio, T., Viau, E., Peccia, J. (2007). Source Tracking Aerosols Released from Land-Applied Class B Biosolids during High-Wind Events. Appl. Environ. Microbiol. 73: 4522-4531 [Abstract] [Full Text]  
  • Paez-Rubio, T., Viau, E., Romero-Hernandez, S., Peccia, J. (2005). Source Bioaerosol Concentration and rRNA Gene-Based Identification of Microorganisms Aerosolized at a Flood Irrigation Wastewater Reuse Site. Appl. Environ. Microbiol. 71: 804-810 [Abstract] [Full Text]  
  • Fedorak, P. M., Rogers, R. E. (1991). Assessment of the Potential Health Risks Associated With the Dissemination of Micro-Organisms From a Landfill Site. Waste Manag Res 9: 537-563 [Abstract]