This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by el-Sherbeeny, M R
Right arrow Articles by Morris, G K
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by el-Sherbeeny, M R
Right arrow Articles by Morris, G K
Agricola
Right arrow Articles by el-Sherbeeny, M R
Right arrow Articles by Morris, G K

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1985 September; 50(3): 611-614

Comparison of gauze swabs and membrane filters for isolation of Campylobacter spp. from surface water.

M R el-Sherbeeny, C Bopp, J G Wells and G K Morris

ABSTRACT

The epidemiology of Campylobacter jejuni indicates that waterborne transmission is important; the organism has been isolated from seawater, fresh water, and estuarine sites. Membrane filtration, with and without use of an enrichment broth, has been the most common method for isolating C. jejuni from water. We evaluated two methods for isolating C. jejuni from water: membrane filtration and gauze filtration. The membrane filters evaluated included 0.22- and 0.45-micron-pore Millipore filters (Millipore Corp., Bedford, Mass.), 0.2- and 0.4-micron-pore Nuclepore filters (Nucleopore Corp., Pleasanton, Calif.), and a 0.45-micron-pore Zetapor filters (AMF Cuno, Meridian, Conn.). The gauze filters included both Moore and Spira swabs. Of the membrane filters evaluated, the 0.45-micron-pore Millipore and Zetapor filters were the most sensitive for recovery of C. jejuni from seeded waters. The 0.45-micron-pore Millipore filter placed in Oosterom broth was better for recovery of C. jejuni from seeded stationary surface waters than either the Spira or Moore swab. However, the 0.45-micron-pore Millipore filter placed on a plate or in enrichment broth was equivalent to the Spira gauze swab when used to examine water from Atlanta area streams. C. jejuni organisms were isolated from 9 of 24 surface water samples representing 5 of 12 streams.


Appl Environ Microbiol. 1985 September; 50(3): 611-614