This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McDaniels, A E
Right arrow Articles by Rankin, C C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McDaniels, A E
Right arrow Articles by Rankin, C C
Agricola
Right arrow Articles by McDaniels, A E
Right arrow Articles by Rankin, C C

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1985 October; 50(4): 755-762

Holding effects on coliform enumeration in drinking water samples.

A E McDaniels, R H Bordner, P S Gartside, J R Haines, K P Brenner and C C Rankin

ABSTRACT

Standard procedures for analyzing drinking water stress the need to adhere to the time and temperature conditions recommended for holding samples collected for microbiological testing. The National Drinking Water Laboratory Certification Program requires compliance with these holding limits, but some investigators have reported difficulties in meeting them. Research was conducted by standard analytical methods to determine if changes occurred when samples were held at 5 and 22 degrees C and analyzed at 0, 24, 30, and 48 h. Samples were analyzed for coliforms by the membrane filter and fermentation-tube procedures and for heterotrophs by the pour plate method. A total of 17 treated water samples were collected from a large municipal distribution system from August to December 1981, and 12 samples were collected from January to May 1983. The samples were dosed with coliforms previously isolated from the water system, Enterobacter cloacae in 1981 and Citrobacter freundii in 1983. The coliform counts declined linearly over time, and the rates of decline were significant at both 5 and 22 degrees C. Within 24 h at 22 degrees C, levels of E. cloacae and C. freundii decreased by 47 and 26%, respectively, and at 5 degrees C, E. cloacae numbers declined by 23%. Results from these representative laboratory-grown coliforms reinforced those previously obtained with naturally occurring coliforms under the same experimental conditions. Significantly, some samples with initially unacceptable counts (greater than 4/100 ml) met the safe drinking water limits after storage at 24 h at 5 and 22 degrees C and would have been classified as satisfactory.(ABSTRACT TRUNCATED AT 250 WORDS)


Appl Environ Microbiol. 1985 October; 50(4): 755-762




This article has been cited by other articles:

  • Pope, M. L., Bussen, M., Feige, M. A., Shadix, L., Gonder, S., Rodgers, C., Chambers, Y., Pulz, J., Miller, K., Connell, K., Standridge, J. (2003). Assessment of the Effects of Holding Time and Temperature on Escherichia coli Densities in Surface Water Samples. Appl. Environ. Microbiol. 69: 6201-6207 [Abstract] [Full Text]