This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ward, R L
Right arrow Articles by Winston, P E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ward, R L
Right arrow Articles by Winston, P E
Agricola
Right arrow Articles by Ward, R L
Right arrow Articles by Winston, P E

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1985 November; 50(5): 1144-1148

Development of methods to measure virus inactivation in fresh waters.

R L Ward and P E Winston

ABSTRACT

This study concerns the identification and correction of deficiencies in methods used to measure inactivation rates of enteric viruses seeded into environmental waters. It was found that viable microorganisms in an environmental water sample increased greatly after addition of small amounts of nutrients normally present in the unpurified seed virus preparation. This burst of microbial growth was not observed after seeding the water with purified virus. The use of radioactively labeled poliovirus revealed that high percentages of virus particles, sometimes greater than 99%, were lost through adherence to containers, especially in less turbid waters. This effect was partially overcome by the use of polypropylene containers and by the absence of movement during incubation. Adherence to containers clearly demonstrated the need for labeled viruses to monitor losses in this type of study. Loss of viral infectivity in samples found to occur during freezing was avoided by addition of broth. Finally, microbial contamination of the cell cultures during infectivity assays was overcome by the use of gentamicin and increased concentrations of penicillin, streptomycin, and amphotericin B.


Appl Environ Microbiol. 1985 November; 50(5): 1144-1148




This article has been cited by other articles:

  • Butot, S., Putallaz, T., Croquet, C., Lamothe, G., Meyer, R., Joosten, H., Sanchez, G. (2007). Attachment of Enteric Viruses to Bottles. Appl. Environ. Microbiol. 73: 5104-5110 [Abstract] [Full Text]  
  • Gassilloud, B., Gantzer, C. (2005). Adhesion-Aggregation and Inactivation of Poliovirus 1 in Groundwater Stored in a Hydrophobic Container. Appl. Environ. Microbiol. 71: 912-920 [Abstract] [Full Text]