This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Reasoner, D J
Right arrow Articles by Geldreich, E E
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Reasoner, D J
Right arrow Articles by Geldreich, E E
Agricola
Right arrow Articles by Reasoner, D J
Right arrow Articles by Geldreich, E E

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1989 April; 55(4): 907-911

Detection of fecal coliforms in water by using [14C]mannitol.

D J Reasoner and E E Geldreich

Microbiological Treatment Branch, U.S. Environmental Protection Agency, Cincinnati, Ohio 45268.

ABSTRACT

Interest in rapid bacterial detection methods for sanitary indicator bacteria in water prompted a study of the use of [U-14C]mannitol to detect fecal coliforms (FC). A simple method which used m-FC broth, membrane filtration, and two-temperature incubation (35 degrees C for 2 h followed by 44.5 degrees C for 2.5 h) was developed. [U-14C]mannitol was added to the medium, and the temperature was raised to 44.5 degrees C after 2 h at 35 degrees C. 14CO2 was collected as Ba14CO3 and assayed by liquid scintillation spectroscopy. Correlations were examined between FC cell numbers at the start of incubation (standard 24-h FC test) and Ba14CO3 counts per minute after 4.5 h. Results indicated that FC numbers ranging from 1 x 10(1) to 2.1 x 10(5) cells could be detected in 4.5 h. Within-sample reproducibility at all cell concentrations was good, but sample-to-sample reproducibility was variable. Comparisons between m-FC broth and m-FC broth modified by substituting D-mannitol for lactose indicated that the standard m-FC broth was the better test medium. Results from experiments in which dimethyl sulfoxide was used to increase permeability of FC to [U-14C]mannitol indicated no increase in 14CO2 production due to dimethyl sulfoxide. Detection of FC by this method may be useful for rapid estimation of FC levels in freshwater recreational areas, for estimating the quality of potable source water, and potentially for emergency testing of potable water, suspected of contamination due to distribution line breaks or cross-connections.


Appl Environ Microbiol. 1989 April; 55(4): 907-911