AEM
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sly, L I
Right arrow Articles by Arunpairojana, V
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sly, L I
Right arrow Articles by Arunpairojana, V
Agricola
Right arrow Articles by Sly, L I
Right arrow Articles by Arunpairojana, V

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1990 March; 56(3): 628-639

Deposition of manganese in a drinking water distribution system.

L I Sly, M C Hodgkinson and V Arunpairojana

Department of Microbiology, University of Queensland, St. Lucia, Brisbane, Australia.

ABSTRACT

The deposition of manganese in a water distribution system with manganese-related "dirty water" problems was studied over a 1-year period. Four monitoring laboratories with Robbins biofilm sampling devices fitted to the water mains were used to correlate the relationship among manganese deposition, the level of manganese in the water, and the chlorination conditions. Manganese deposition occurred by both chemical and microbial processes. Chemical deposition occurred when Mn(II) not removed during water treatment penetrated the filters and entered the distribution system, where it was oxidized by chlorine and chlorine dioxide used for disinfection. Microbial deposition occurred in areas with insufficient chlorination to control the growth of manganese-depositing biofilm. At 0.05 mg of Mn(II) per liter, the chemical deposition rate was much greater than microbial deposition. Significant deposition occurred at 0.03 mg of manganese per liter, and dirty water complaints were not eliminated until manganese levels were continuously less than 0.02 mg/liter and chlorination levels were greater than 0.2 mg/liter. A guideline level of 0.01 mg of manganese per liter is recommended.


Appl Environ Microbiol. 1990 March; 56(3): 628-639







Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
J. Bacteriol. Microbiol. Mol. Biol. Rev. Eukaryot. Cell All ASM Journals

Copyright © 1990 by the American Society for Microbiology. All rights reserved.