Appl Environ Microbiol. 1992 March; 58(3): 900-904
Department of Biology, University of Missouri-St. Louis 63121.
ABSTRACT
Short-term (15-min-duration) and long-term (5- to 6-day-duration) test procedures have been developed for determining the efficiency of the removal of bacteriophage phi X174 by air-sterilizing filters. These procedures were sensitive enough to measure a 10(8)-fold reduction in the number of bacteriophage. A filter commonly used in industrial air sterilizations (Domnick-Hunter Bio-X borosilicate glass) effected a 10(8)-fold removal of viable phage in both short-term and long-term tests. A prototype low-flux, hollow-fiber membrane gave similar results; however, a prototype high-flux, hollow-fiber membrane removed only about 99.999% of the bacteriophage in short-term tests.