This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Selifonova, O
Right arrow Articles by Barkay, T
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Selifonova, O
Right arrow Articles by Barkay, T
Agricola
Right arrow Articles by Selifonova, O
Right arrow Articles by Barkay, T

 Previous Article  |  Next Article 

Appl Environ Microbiol. 1993 September; 59(9): 3083-3090

Bioluminescent sensors for detection of bioavailable Hg(II) in the environment.

O Selifonova, R Burlage and T Barkay

Center for Environmental Diagnostics and Bioremediation, University of West Florida, Pensacola 32514.

ABSTRACT

Biosensors for the detection of pollutants in the environment can complement analytical methods by distinguishing bioavailable from inert, unavailable forms of contaminants. By using fusions of the well-understood Tn21 mercury resistance operon (mer) with promoterless luxCDABE from Vibrio fischeri, we have constructed and tested three biosensors for Hg(II). Bioluminescence specified by pRB28, carrying merRo/pT, by pOS14, mediating active transport of Hg(II), and by pOS15, containing an intact mer operon, was measured in rich and minimal media. The highest sensitivities were achieved in minimal medium and were 1, 0.5, and 25 nM Hg(II) for pRB28, pOS14, and pOS15, respectively. The utility of the biosensors in natural waters was demonstrated with freshwater, rain, and estuarine samples supplemented with Hg(II). mer-lux carried by pRB28 and pOS14 responded to Hg(II) in mercury-contaminated water samples collected from a freshwater pond. Semiquantitative analyses based on light emission in samples collected from the inlet (analytically determined total mercury, approximately 20 nM) and outlet (total mercury, approximately 7 nM) of the pond showed bioavailable mercury at approximately 20 and 1 to 2 nM, respectively. Thus, the biosensors described here semiquantitatively detect bioavailable inorganic mercury (at a nanomolar to micromolar concentration range) in contaminated waters.


Appl Environ Microbiol. 1993 September; 59(9): 3083-3090




This article has been cited by other articles:

  • Golding, G. R., Sparling, R., Kelly, C. A. (2008). Effect of pH on Intracellular Accumulation of Trace Concentrations of Hg(II) in Escherichia coli under Anaerobic Conditions, as Measured Using a mer-lux Bioreporter. Appl. Environ. Microbiol. 74: 667-675 [Abstract] [Full Text]  
  • Werlen, C., Jaspers, M. C. M., van der Meer, J. R. (2004). Measurement of Biologically Available Naphthalene in Gas and Aqueous Phases by Use of a Pseudomonas putida Biosensor. Appl. Environ. Microbiol. 70: 43-51 [Abstract] [Full Text]  
  • Strong, L. C., Rosendahl, C., Johnson, G., Sadowsky, M. J., Wackett, L. P. (2002). Arthrobacter aurescens TC1 Metabolizes Diverse s-Triazine Ring Compounds. Appl. Environ. Microbiol. 68: 5973-5980 [Abstract] [Full Text]  
  • Axtell, C. A., Beattie, G. A. (2002). Construction and Characterization of a proU-gfp Transcriptional Fusion That Measures Water Availability in a Microbial Habitat. Appl. Environ. Microbiol. 68: 4604-4612 [Abstract] [Full Text]  
  • Yarwood, R. R., Rockhold, M. L., Niemet, M. R., Selker, J. S., Bottomley, P. J. (2002). Noninvasive Quantitative Measurement of Bacterial Growth in Porous Media under Unsaturated-Flow Conditions. Appl. Environ. Microbiol. 68: 3597-3605 [Abstract] [Full Text]  
  • Stiner, L., Halverson, L. J. (2002). Development and Characterization of a Green Fluorescent Protein-Based Bacterial Biosensor for Bioavailable Toluene and Related Compounds. Appl. Environ. Microbiol. 68: 1962-1971 [Abstract] [Full Text]  
  • Hay, A. G., Rice, J. F., Applegate, B. M., Bright, N. G., Sayler, G. S. (2000). A Bioluminescent Whole-Cell Reporter for Detection of 2,4-Dichlorophenoxyacetic Acid and 2,4-Dichlorophenol in Soil. Appl. Environ. Microbiol. 66: 4589-4594 [Abstract] [Full Text]  
  • Neilson, J. W., Pierce, S. A., Maier, R. M. (1999). Factors Influencing Expression of luxCDABE and nah Genes in Pseudomonas putida RB1353(NAH7, pUTK9) in Dynamic Systems. Appl. Environ. Microbiol. 65: 3473-3482 [Abstract] [Full Text]  
  • Justus, T., Thomas, S. M. (1999). Evaluation of transcriptional fusions with green fluorescent protein versus luciferase as reporters in bacterial mutagenicity tests. Mutagenesis 14: 351-356 [Abstract] [Full Text]  
  • Gupta, A., Maynes, M., Silver, S. (1998). Effects of Halides on Plasmid-Mediated Silver Resistance in Escherichia coli. Appl. Environ. Microbiol. 64: 5042-5045 [Abstract] [Full Text]  
  • Ben-Israel, O., Ben-Israel, H., Ulitzur, S. (1998). Identification and Quantification of Toxic Chemicals by Use of Escherichia coli Carrying lux Genes Fused to Stress Promoters. Appl. Environ. Microbiol. 64: 4346-4352 [Abstract] [Full Text]  
  • Applegate, B. M., Kehrmeyer, S. R., Sayler, G. S. (1998). A Chromosomally Based tod-luxCDABE Whole-Cell Reporter for Benzene, Toluene, Ethybenzene, and Xylene (BTEX) Sensing. Appl. Environ. Microbiol. 64: 2730-2735 [Abstract] [Full Text]