Applied and Environmental Microbiology, October 2001, p. 4614-4618, Vol. 67, No. 10
Departamento de Microbiologia, Instituto de
Ciências Biomédicas, Universidade de São Paulo,
05508-900 São Paulo, São Paulo, Brazil
Received 12 March 2001/Accepted 31 July 2001
PCR is the best method for the detection of enteric viruses present
at low concentrations in environmental samples. However, some organic
and inorganic compounds present in these samples can interfere in the
reaction. Many of these substances are cytotoxic, too. The ZP60S filter
membranes used in addition to fluorpentane treatment are quite
efficient for virus concentration and simultaneous elimination of
cytotoxicity from environmental samples. In this study, both procedures
were used to promote the elimination of reverse transcriptase PCR
(RT-PCR) inhibitors from sewage and sewage-polluted creek water.
Samples were subjected separately to each of the following procedures:
filtration through electropositive filter membranes (ZP60S), organic
extraction with Vertrel XF, and filtration through ZP60S followed by
organic extraction. Afterwards, aliquots were experimentally inoculated
with rotavirus SA-11 RNA and subjected to RT-seminested PCR for
amplification of the VP7 gene. Results showed that the ZP60S membranes
efficiently eliminated the RT-PCR inhibitors from water samples. The
sample processing method was also applied to 31 in natura sewage and
creek water samples for detection of naturally occurring rotavirus. A
duplex seminested PCR was used for the quick detection of couples of the four rotavirus genotypes (G1 to G4). Eight samples (25.8%) were
positive, and rotavirus sequences were not detected in 23 (74.2%). Results were confirmed by direct immunoperoxidase
method. In summary, the use of electropositive filter membrane is
appropriate for the elimination of substances that can interfere with
RT-PCR, obviating additional sample purification methods.
0099-2240/01/$04.00+0 DOI: 10.1128/AEM.67.10.4614-4618.2001
Copyright © 2001, American Society for Microbiology. All rights reserved.
Electropositive Filter Membrane as an Alternative
for the Elimination of PCR Inhibitors from Sewage and Water
Samples
*
Corresponding author. Mailing address: Departamento de
Microbiologia, Instituto de Ciências Biomédicas,
Universidade de São Paulo, Av. Lineu Prestes 1374, CEP 05508-900 São Paulo, SP, Brazil. Phone: 55-11-3818 7341. Fax: 55-11-3818 7354. E-mail: dumehner{at}icb.usp.br.
This article has been cited by other articles:
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»