This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kuhn, R. C.
Right arrow Articles by Oshima, K. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kuhn, R. C.
Right arrow Articles by Oshima, K. H.
Agricola
Right arrow Articles by Kuhn, R. C.
Right arrow Articles by Oshima, K. H.

 Previous Article  |  Next Article 

Applied and Environmental Microbiology, April 2002, p. 2066-2070, Vol. 68, No. 4
0099-2240/02/$04.00+0     DOI: 10.1128/AEM.68.4.2066-2070.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.

Effects of pH and Magnetic Material on Immunomagnetic Separation of Cryptosporidium Oocysts from Concentrated Water Samples

Ryan C. Kuhn, Channah M. Rock, and Kevin H. Oshima*

Department of Biology, New Mexico State University, Las Cruces, New Mexico 88003

Received 15 October 2001/ Accepted 25 January 2002

In this study, we examined the effect that magnetic materials and pH have on the recoveries of Cryptosporidium oocysts by immunomagnetic separation (IMS). We determined that particles that were concentrated on a magnet during bead separation have no influence on oocyst recovery; however, removal of these particles did influence pH values. The optimal pH of the IMS was determined to be 7.0. The numbers of oocysts recovered from deionized water at pH 7.0 were 26.3% higher than those recovered from samples that were not at optimal pH. The results indicate that the buffers in the IMS kit did not adequately maintain an optimum pH in some water samples. By adjusting the pH of concentrated environmental water samples to 7.0, recoveries of oocysts increased by 26.4% compared to recoveries from samples where the pH was not adjusted.


* Corresponding author. Mailing address: Department of Biology, New Mexico State University, Dept. 3AF, P.O. Box 30001, Las Cruces, NM 88003. Phone: (505) 646-2092. Fax: (505) 646-5665. E-mail: koshima{at}nmsu.edu.


Applied and Environmental Microbiology, April 2002, p. 2066-2070, Vol. 68, No. 4
0099-2240/02/$04.00+0     DOI: 10.1128/AEM.68.4.2066-2070.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Hill, V. R., Kahler, A. M., Jothikumar, N., Johnson, T. B., Hahn, D., Cromeans, T. L. (2007). Multistate Evaluation of an Ultrafiltration-Based Procedure for Simultaneous Recovery of Enteric Microbes in 100-Liter Tap Water Samples. Appl. Environ. Microbiol. 73: 4218-4225 [Abstract] [Full Text]  
  • Jiang, J., Alderisio, K. A., Singh, A., Xiao, L. (2005). Development of Procedures for Direct Extraction of Cryptosporidium DNA from Water Concentrates and for Relief of PCR Inhibitors. Appl. Environ. Microbiol. 71: 1135-1141 [Abstract] [Full Text]  
  • Francy, D. S., Simmons, O. D. III, Ware, M. W., Granger, E. J., Sobsey, M. D., Schaefer, F. W. III (2004). Effects of Seeding Procedures and Water Quality on Recovery of Cryptosporidium Oocysts from Stream Water by Using U.S. Environmental Protection Agency Method 1623. Appl. Environ. Microbiol. 70: 4118-4128 [Abstract] [Full Text]  
  • Davies, C. M., Kaucner, C., Deere, D., Ashbolt, N. J. (2003). Recovery and Enumeration of Cryptosporidium parvum from Animal Fecal Matrices. Appl. Environ. Microbiol. 69: 2842-2847 [Abstract] [Full Text]