This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yáñez, M. A.
Right arrow Articles by Catalán, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yáñez, M. A.
Right arrow Articles by Catalán, V.
Agricola
Right arrow Articles by Yáñez, M. A.
Right arrow Articles by Catalán, V.

 Previous Article  |  Next Article 

Applied and Environmental Microbiology, July 2005, p. 3433-3441, Vol. 71, No. 7
0099-2240/05/$08.00+0     doi:10.1128/AEM.71.7.3433-3441.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.

Quantitative Detection of Legionella pneumophila in Water Samples by Immunomagnetic Purification and Real-Time PCR Amplification of the dotA Gene

M. A. Yáñez, C. Carrasco-Serrano, V. M. Barberá, and V. Catalán*

Labaqua, Alicante, Spain

Received 30 September 2004/ Accepted 11 January 2005

A new real-time PCR assay was developed and validated in combination with an immunomagnetic separation system for the quantitative determination of Legionella pneumophila in water samples. Primers that amplify simultaneously an 80-bp fragment of the dotA gene from L. pneumophila and a recombinant fragment including a specific sequence of the gyrB gene from Aeromonas hydrophila, added as an internal positive control, were used. The specificity, limit of detection, limit of quantification, repetitivity, reproducibility, and accuracy of the method were calculated, and the values obtained confirmed the applicability of the method for the quantitative detection of L. pneumophila. Moreover, the efficiency of immunomagnetic separation in the recovery of L. pneumophila from different kinds of water was evaluated. The recovery rates decreased as the water contamination increased (ranging from 59.9% for distilled water to 36% for cooling tower water), and the reproducibility also decreased in parallel to water complexity. The feasibility of the method was evaluated by cell culture and real-time PCR analysis of 60 samples in parallel. All the samples found to be positive by cell culture were also positive by real-time PCR, while only eight samples were found to be positive only by PCR. Finally, the correlation of both methods showed that the number of cells calculated by PCR was 20-fold higher than the culture values. In conclusion, the real-time PCR method combined with immunomagnetic separation provides a sensitive, specific, and accurate method for the rapid quantification of L. pneumophila in water samples. However, the recovery efficiency of immunomagnetic separation should be considered in complex samples.


* Corresponding author. Mailing address: Labaqua, Pol. Ind. Las Atalayas, c/Del Dracma, 16-18, 03114 Alicante, Spain. Phone: 34.96510.60.70. Fax: 34.96510.60.80. E-mail: vicente.catalan{at}labaqua.es.


Applied and Environmental Microbiology, July 2005, p. 3433-3441, Vol. 71, No. 7
0099-2240/05/$08.00+0     doi:10.1128/AEM.71.7.3433-3441.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • To, H., Koyama, T., Nagai, S., Tuchiya, K., Nunoya, T. (2009). Development of quantitative real-time polymerase chain reaction for detection of and discrimination between Erysipelothrix rhusiopathiae and other Erysipelothrix species. jvdi 21: 701-706 [Abstract] [Full Text]  
  • Dusserre, E., Ginevra, C., Hallier-Soulier, S., Vandenesch, F., Festoc, G., Etienne, J., Jarraud, S., Molmeret, M. (2008). A PCR-Based Method for Monitoring Legionella pneumophila in Water Samples Detects Viable but Noncultivable Legionellae That Can Recover Their Cultivability. Appl. Environ. Microbiol. 74: 4817-4824 [Abstract] [Full Text]  
  • Yaradou, D. F., Hallier-Soulier, S., Moreau, S., Poty, F., Hillion, Y., Reyrolle, M., Andre, J., Festoc, G., Delabre, K., Vandenesch, F., Etienne, J., Jarraud, S. (2007). Integrated Real-Time PCR for Detection and Monitoring of Legionella pneumophila in Water Systems. Appl. Environ. Microbiol. 73: 1452-1456 [Abstract] [Full Text]  
  • Joly, P., Falconnet, P.-A., Andre, J., Weill, N., Reyrolle, M., Vandenesch, F., Maurin, M., Etienne, J., Jarraud, S. (2006). Quantitative Real-Time Legionella PCR for Environmental Water Samples: Data Interpretation. Appl. Environ. Microbiol. 72: 2801-2808 [Abstract] [Full Text]