This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Costafreda, M. I.
Right arrow Articles by Pintó, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Costafreda, M. I.
Right arrow Articles by Pintó, R. M.
Agricola
Right arrow Articles by Costafreda, M. I.
Right arrow Articles by Pintó, R. M.

 Previous Article  |  Next Article 

Applied and Environmental Microbiology, June 2006, p. 3846-3855, Vol. 72, No. 6
0099-2240/06/$08.00+0     doi:10.1128/AEM.02660-05
Copyright © 2006, American Society for Microbiology. All Rights Reserved.

Development, Evaluation, and Standardization of a Real-Time TaqMan Reverse Transcription-PCR Assay for Quantification of Hepatitis A Virus in Clinical and Shellfish Samples

M. Isabel Costafreda, Albert Bosch,* and Rosa M. Pintó

Enteric Virus Laboratory, Department of Microbiology, School of Biology, University of Barcelona, Barcelona, Spain

Received 10 November 2005/ Accepted 18 March 2006

A standardized real-time reverse transcription-PCR (RT-PCR) assay has been developed for an accurate estimation of the number of genome copies of hepatitis A virus (HAV) in clinical and shellfish samples. Real-time procedures were based on the amplification of a fragment of the highly conserved 5' noncoding region and detection through an internal fluorescent probe, including TaqMan and beacon chemistries, in one- and two-step RT-PCR formats. The best performance in terms of sensitivity and reproducibility was achieved by a one-step TaqMan RT-PCR, with a sensitivity enabling the detection of 0.05 infectious unit and 10 copies of a single-stranded RNA (ssRNA) synthetic transcript. Standard reagents, such as a mengovirus strain and an ssRNA transcript, were employed as controls of nucleic acid extraction and RT-PCR, respectively. The test proved to be highly specific after a broad panel of enteric viruses was tested. Sequence alignment of target regions of the primers and probe proved them to be adequate for the quantification of all HAV genotypes. In addition, a quasispecies analysis of the mutant spectrum indicated that these regions are not prone to variability, thus confirming their robustness.


* Corresponding author. Mailing address: Department of Microbiology, School of Biology, University of Barcelona, Diagonal 645, 08028 Barcelona, Spain. Phone: (34) 934034620. Fax: (34) 934034629. E-mail: abosch{at}ub.edu.


Applied and Environmental Microbiology, June 2006, p. 3846-3855, Vol. 72, No. 6
0099-2240/06/$08.00+0     doi:10.1128/AEM.02660-05
Copyright © 2006, American Society for Microbiology. All Rights Reserved.




This article has been cited by other articles:

  • Pinto, R. M., Costafreda, M. I., Bosch, A. (2009). Risk Assessment in Shellfish-Borne Outbreaks of Hepatitis A. Appl. Environ. Microbiol. 75: 7350-7355 [Abstract] [Full Text]  
  • Butot, S., Putallaz, T., Amoroso, R., Sanchez, G. (2009). Inactivation of Enteric Viruses in Minimally Processed Berries and Herbs. Appl. Environ. Microbiol. 75: 4155-4161 [Abstract] [Full Text]  
  • Le Guyader, F. S., Parnaudeau, S., Schaeffer, J., Bosch, A., Loisy, F., Pommepuy, M., Atmar, R. L. (2009). Detection and Quantification of Noroviruses in Shellfish. Appl. Environ. Microbiol. 75: 618-624 [Abstract] [Full Text]  
  • Le Guyader, F. S., Le Saux, J.-C., Ambert-Balay, K., Krol, J., Serais, O., Parnaudeau, S., Giraudon, H., Delmas, G., Pommepuy, M., Pothier, P., Atmar, R. L. (2008). Aichi Virus, Norovirus, Astrovirus, Enterovirus, and Rotavirus Involved in Clinical Cases from a French Oyster-Related Gastroenteritis Outbreak. J. Clin. Microbiol. 46: 4011-4017 [Abstract] [Full Text]  
  • Gutierrez-Aguirre, I., Steyer, A., Boben, J., Gruden, K., Poljsak-Prijatelj, M., Ravnikar, M. (2008). Sensitive Detection of Multiple Rotavirus Genotypes with a Single Reverse Transcription-Real-Time Quantitative PCR Assay. J. Clin. Microbiol. 46: 2547-2554 [Abstract] [Full Text]  
  • da Silva, A. K., Le Saux, J.-C., Parnaudeau, S., Pommepuy, M., Elimelech, M., Le Guyader, F. S. (2007). Evaluation of Removal of Noroviruses during Wastewater Treatment, Using Real-Time Reverse Transcription-PCR: Different Behaviors of Genogroups I and II. Appl. Environ. Microbiol. 73: 7891-7897 [Abstract] [Full Text]  
  • Saikaly, P. E., Barlaz, M. A., de los Reyes, F. L. III (2007). Development of Quantitative Real-Time PCR Assays for Detection and Quantification of Surrogate Biological Warfare Agents in Building Debris and Leachate. Appl. Environ. Microbiol. 73: 6557-6565 [Abstract] [Full Text]  
  • Butot, S., Putallaz, T., Sanchez, G. (2007). Procedure for Rapid Concentration and Detection of Enteric Viruses from Berries and Vegetables. Appl. Environ. Microbiol. 73: 186-192 [Abstract] [Full Text]