Previous Article | Next Article ![]()
Applied and Environmental Microbiology, October 2002, p. 4853-4862, Vol. 68, No. 10
0099-2240/02/$04.00+0 DOI: 10.1128/AEM.68.10.4853-4862.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.
George E. Brown Jr. Salinity Laboratory, U.S. Department of Agriculture-Agricultural Research Service, Riverside, California 92507,1 National Animal Disease Center, U.S. Department of Agriculture-Agricultural Research Service, Ames, Iowa 50010,2 Orange County Water District, Fountain Valley, California 927283
Received 21 March 2002/ Accepted 17 July 2002
|
|
|---|
3.5 x 104 CFU g-1. E. coli O157:H7 levels detected in wetland samples decreased by about 2 logs between wetland influents and effluents. The detection limit of the assay in soil was improved to less than 10 CFU g-1 with a 16-h enrichment. These results indicate that the developed PCR assay is suitable for quantitative determination of E. coli O157:H7 in environmental samples and represents a considerable advancement in pathogen quantification in different ecosystems. |
|
|---|
The wash waters from dairy and beef cattle operations harbor different bacterial species including human pathogens such as enterohemorrhagic Escherichia coli O157:H7. E. coli O157:H7 causes a wide spectrum of disease symptoms in humans, such as diarrhea ranging from mild to bloody, hemorrhagic colitis, and complications including hemolytic-uremic syndrome (HUS) and seizures that are particularly severe in children (14). E. coli O157:H7 strains are generally lysogenized with one or more phages carrying genes for Shiga-like toxins (7, 22). Shiga-like toxins play a major role in the pathogenesis of hemorrhagic colitis and HUS through cytotoxic effects on cells of the kidneys, intestines, central nervous system, and other organs (14, 23). E. coli O157:H7 also harbors a 43-kb pathogenicity island, termed the locus of enterocyte effacement, containing virulence attributes required for the formation of attaching and effacing lesions on the target host cells (17, 19, 26, 33). The formation of the attaching-effacing lesion phenotype requires interactions between intimin, a bacterial cell surface protein, and a translocated intimin receptor (Tir) (2, 17, 19, 20). Tir is secreted by bacterial cells into the host cells, where it is localized into the host cell membrane and serves as a docking point for bacterial intimin (15). Intimin and Tir are encoded by the genes eae and tir, respectively, which are present in the locus of enterocyte effacement (1). The intimin proteins of pathogenic E. coli strains are highly divergent in the amino acid sequence at the carboxy terminus, and based on this sequence variation, intimins have been classified into five subgroups with E. coli O157:H7 strains occurring in type Y (25).
Since dairy and beef cattle are considered important reservoirs for E. coli O157:H7 (6, 34), this pathogen could potentially enter the drinking water supply from cattle waste wash water. As wastewater is being increasingly used in the irrigation of crops, there is a danger of inadequate treatment to eliminate bacterial pathogens. Also, recent alterations in methods of food production and delivery to consumers have exacerbated problems with pathogenic bacteria such as E. coli O157:H7. The increasing popularity of organic food production has led to widespread composting of animal manure for use in crop production. Problems have often occurred as a consequence of temperatures during composting being insufficient to kill enteric bacteria.
Methods for the effective treatment of wastewater and manure are essential to ensure the safety of drinking water and crops. To ascertain the effectiveness of wastewater treatment, it is imperative to develop methods that would allow rapid and sensitive detection of bacterial pathogens in agricultural and urban water runoffs, soils, and cattle manure before and after treatment of these important recyclable resources. The availability of methods for effective treatment and detection of pathogens in environmental samples would reduce the incidence of human illnesses by preventing the transmission of bacterial pathogens to humans. This in turn would save millions of dollars in health-related medical costs and food recalls.
PCR has become an important method for the rapid, sensitive, and specific detection of bacterial pathogens. Recent advances in the synthesis of fluorogenic probes and the development of instrumentation for continuous monitoring of fluorescence have facilitated the development of real-time PCR assays for specific, automated detection and quantitation of amplified gene products (10). Real-time multiplex PCR has been used for the detection and quantification of E. coli O157:H7 in food and clinical samples (4, 21, 27, 28), but absolute quantification of this pathogen by this technology has not been tested vigorously with wastewater and environmental samples.
In this study, a real-time multiplex PCR assay with specific probes (Table 1) was used to detect and quantify E. coli O157:H7 in dairy wastewater prior to and following treatment by a subsurface constructed wetland. The main benefit of simultaneous multiplexing with quantification is cost efficiency and a higher throughput. The objective of the present study was to develop a real-time multiplex PCR assay to detect and quantify E. coli O157:H7 and to determine its suitability for monitoring the effectiveness of a subsurface constructed wetland system in reducing E. coli O157:H7 levels in dairy waste wash water. The real-time PCR method was also evaluated for the detection and quantification of E. coli O157:H7 in soil samples seeded with known numbers of the organism. An iCycle iQ detection system (Bio-Rad, Hercules, Calif.) consisting of a thermal cycler, an optical module, and detection software was used for the PCR assay validation. This instrument monitored incremental increases in fluorescence at successive PCR cycles in real time and used this data to establish a threshold cycle (CT) for the assay. During the early rounds of amplification, the changes in fluorescence are negligible and beyond the sensitivity of the system detector. At some point during cycling, a change will register with the detection system. This is called the threshold cycle (CT) and is proportional to the amount of the starting amount of nucleic acid (10). Since the threshold cycle is inversely proportional to the copy number of a target gene, this allowed for the construction of standard curves by using samples containing 10-fold dilutions of target genes.
|
View this table: [in a new window] |
TABLE 1. Nucleotide sequences of primers and fluorogenic probes
|
|
|
|---|
|
View this table: [in a new window] |
TABLE 2. Specificity of conventional multiplex PCR assay for detection of the stx1 and stx2 genes of STEC and the eae gene of E. coli O157:H7
|
|
View this table: [in a new window] |
TABLE 3. Sensitivity of real-time multiplex PCR assay for detection and quantification of the stx1 and the stx2 genes of STEC, eae of E. coli O157:H7, and related strains
|
DNA isolation from pure culture and environmental samples.
Genomic DNA was isolated from a pure culture of E. coli O157:H7 strain 3081, grown for 12 h at 37°C, and extracted with the Qiagen tissue kit (QIAamp DNA Mini kit; Qiagen, Valencia, Calif.) according to the manufacturer's protocol. Total bacterial community DNA was extracted from environmental samples to determine the detection limits of E. coli O157:H7 strain 3081 by real-time PCR. The DNA was extracted from 500 mg of soil or fecal samples or 100 ml of water with UltraClean soil, fecal, and water DNA kits (MO BIO, Inc., Solana Beach, Calif.) according to the manufacturer's protocol. The 100 ml of water was filtered and concentrated into 0.25 ml for DNA extraction with the MO BIO water DNA kit.
Laboratory seeding experiments.
Arlington sandy loam soil was obtained from the University of California, Riverside, Agricultural Experiment Station. Soil was removed from the top 15 cm with a stainless steel shovel, passed through a 4-mm-pore-size stainless steel sieve, and treated with 500 mg of methyl bromide kg-1 to fumigate the soil. The soil was stored at 4°C and tested by bacteriological and PCR techniques to ensure that it was E. coli O157:H7 negative prior to use. An overnight culture of E. coli strain 3081 was serially diluted in tryptic soy broth, and the number of CFU of bacteria in each dilution was determined by plating on cefixime-tellurite (CT)-SMAC agar with BCIG (5-bromo-4-chloro-3-indoxyl-ß-D-glucuronide) containing 0.05 mg of cefixime liter-1 and 2.5 mg of tellurite liter-1 (LAB M; IDG). The average titer (CFU milliliter-1) of three replicates was determined. For the spiked experiment, 10 g of soil was seeded with a 0- to 10-fold dilution series of E. coli O157:H7 strain 3081 in flasks containing 90 ml of modified Luria-Bertani broth consisting of 8 mg of vancomycin liter-1, 0.05 mg of cefixime liter-1, and 10 mg of cefsulodin liter-1. The inoculated flasks were incubated at 37°C with agitation at 160 rpm. Samples were vortexed for 30 s, and 2-ml aliquots were taken after 0, 2, 8, 16, and 24 h for DNA extraction. The DNA extracted from the enrichment broth was used as a template for real-time PCR. In experiments to compare real-time PCR with the conventional culture method, the enrichment broths of seeded soil samples were also plated onto CT-SMAC agar plates. Sorbitol-negative colonies were enumerated.
Layout of wetlands, sampling scheme, and microbiological analysis.
The project design included two wetlands operating in parallel, in addition to a raw and a facultative pond for central collection of wash water prior to treatment (Fig. 1). The constructed wetlands utilized a horizontal subsurface flow system where wash water treatment occurred beneath the surface of the gravel, which was planted with shallow but densely rooted herbaceous plants. Wetland 1 was an end-loading design, where the wash water entered through multiple inlets into coarse gravel, reeds (Phragmites communus), and bulrushes (Scirpus validus) and then drained into the collection box at the end of the basin. Wetland 2 was a side-loading basin, where wash water entered through multiple inlets along both sides of the wetland and passed through a narrow gravel bed, containing reeds and bulrushes, before being collected through a perforated pipe along the center of the wetlands which drained to the collection box.
![]() View larger version (62K): [in a new window] |
FIG. 1. Schematic of the dairy wash water wetlands used as a treatment facility for the removal of dairy waste and other compounds. All wastewater received in the wetlands was from the milking parlor. The wash water was drained into the raw water lagoon (1), moved through 3-in.-diameter polyvinyl chloride pipes by gravity to an aeration pond, and passed through two parallel wetlands. Water samples were collected from the raw dairy wastewater lagoon (1), facultative pond (2), wetland 1 influent (3), wetland 2 influent (5), wetland 1 effluent (4), and wetland 2 effluent (6).
|
One gram or 1 ml of environmental samples was added to 9 ml of tryptic soy broth, vortexed briefly, serially diluted, and plated for the enumeration of total heterotrophic bacteria, total E. coli, and E. coli O157 on tryptic soy agar, SMAC, and CT-SMAC agar, respectively. The plates were incubated at 25°C for heterotrophic bacterial counts and 37°C for total E. coli and E. coli O157 for 24 h. Six sorbitol-negative, translucent colonies per sample were tested by multiplex PCR to determine the presence of the three genes. Additionally, isolates that were sorbitol positive or ß-glucuronidase positive (red-pink colonies with a purple center or green colonies) were enumerated as other E. coli strains.
Real-time multiplex PCR assay for quantification of E. coli O157:H7 strain 3081.
A single primer-probe reaction was compared with a multiplex primer-probe reaction to determine any significant differences in the CT values. E. coli O157:H7 strain 3081 genomic DNA (7.9 pg ml-1) was amplified in both single and multiplex reactions. To demonstrate the detection range of multiplex PCR, 10-fold serial dilutions containing 7.9 x 100 to 7.9 x 10-9 pg of genomic DNA ml-1 were assayed for the stx1, stx2, and eae genes. PCR was performed in a 50-µl volume containing 200 µM deoxynucleoside triphosphates (dNTPs), 2 µl of genomic DNA from each concentration, 2.5 U of AmpliTaq Gold polymerase, 5 µl of 10x TaqMan buffer (PE Applied Biosystems, Foster City, Calif.), 0.3 µM (each) primer, 0.1 µM (each) probe, and 3 mM MgCl2. Genomic DNA purified from E. coli O157:H7 strain 3081 was used as a template for the positive control. Reaction mixtures were dispensed into a 96-well, thin-wall PCR plate (Bio-Rad), covered with optically clear sealing film, and centrifuged briefly. PCR was performed with the iCycle iQ thermal cycler with the following cycle conditions: denaturation at 95°C for 10 min and 50 cycles of 94°C for 20 s, 55°C for 30 s, and 72°C for 40 s, followed by a 5-min extension at 72°C and holding at 4°C.
The iCycle iQ real-time PCR detection system and software were used for data analyses. This system used a thermal cycler, an optical module, and detection software to quantify PCR products in real time, as revealed by the increase of fluorescence signal by 5'-nuclease activity during the amplification process. The threshold cycle (CT) for each standard was plotted against the log of starting quantity to construct the standard curve used to quantify genes in the unknown samples.
Multiplex PCR quantification of environmental samples.
Template DNA (2 µl) was added to 48 µl of the reaction mixture as described above, except that the concentrations of MgCl2 and dNTPs were optimized to 5 mM and 450 µM, respectively. Amplification conditions were as described above for all environmental samples. E. coli O157:H7 concentrations in environmental samples were confirmed quantitatively by assaying serial dilutions (7.9 x 100 to 7.9 x 10-9 pg ml-1) of strain 3081 DNA in the same plate. Dilution series and environmental samples were tested in triplicate.
Standardization and amplification efficiency.
Standard curves generated from plotting CT versus log10 of starting DNA quantities (picograms) were used for determining the detection limit of the assay. The standard curve was constructed by using known quantities of genomic DNA (7.9 x 100 to 7.9 x 10-9 pg ml-1) extracted from samples containing 6.4 x 10-2 to 6.4 x 108 CFU of E. coli O157:H7 ml-1. The concentration of the extracted DNA was measured by an Ultrospec 4000 spectrophotometer with Swift II application software (Pharmacia Biotech, Cambridge, England), and numbers of CFU milliliter-1 were determined by plating culture dilutions on CT-SMAC. The titers (CFU milliliter-1) of E. coli O157:H7 present in unknown samples were determined from the standard curve. For a comparison of PCR amplification efficiencies and detection sensitivities among different experiments, slopes of the standard curves were calculated by performing a linear regression analysis with the iCycle iQ software. A mixture of all PCR reagents without any DNA was used as a negative control. Amplification efficiency (E) was estimated by using the slope of the standard curve and the formula E = (10-1/slope) - 1. A reaction with 100% efficiency will generate a slope of -3.32.
Standardization of DNA quantities between known and unknown samples was accomplished by dividing total numbers of CFU of E. coli O157:H7 strain 3081 milliliter-1 by the mean starting DNA concentration of that CFU milliliter-1 from the instrument analysis. This resulted in a CFU milliliter-1 index, which was used as a multiplier to calculate the CFU milliliter-1 for all unknown samples. The CFU milliliter-1 index was obtained from the highest DNA quantity to estimate CFU milliliter-1 from lower DNA quantities. This approach was used because the instrument can give reports in either concentrations or copy numbers, and for environmental samples, it is easier to understand results in actual numbers than in concentrations or copy numbers. For example, in the spiked soil calculated numbers of CFU milliliter-1 from plates for E. coli O157:H7 strain 3081 were 6.4 x 108 after 16 h of growth at 37°C. The mean starting quantity from the instrument was 2.8 x 101 CFU ml-1, resulting in a CFU milliliter-1 index of 2.29 x 107. This number was used as a factor for the determination of CFU milliliter-1 of unknown samples with starting mean DNA concentrations determined by the instrument analysis. This process allowed for the establishment of a consistent method for calculating DNA quantities and the corresponding CFU milliliter-1 in unknown samples. At the same time, DNA from serial dilutions with known CFU milliliter-1 was included in every reaction to cross check the accuracy of the calculations.
Statistical analysis.
Data analyses of environmental and laboratory samples were performed with SAS software (SAS/STAT User's Guide, Release 6.03; SAS Institute Inc., Cary, N.C.). Analyses of variance, means, and standard deviations were conducted to determine whether there were significant differences among mean quantities of pathogens for each sampling point.
|
|
|---|
Standard curves, detection limits, and amplification efficiencies.
The detection sensitivity of the quantitative real-time PCR assay was determined by testing triplicate sets of genomic DNA prepared from serial dilutions (6.4 x 10-2 to 6.4 x 108 CFU ml-1) of E. coli strain 3081 (Fig. 2). The results were reported as threshold cycle numbers versus log starting quantities of DNA. Positive signals were found in all dilutions except those where the DNA concentrations were below 7.9 x 10-5 pg ml-1. The CT values were also plotted against CFU milliliter-1 (6.4 x 10-2 to 6.4 x 108 CFU ml-1) in 10-fold serial dilutions of the E. coli O157:H7 culture used for extracting genomic DNA. Based on this approach, a correlation was observed between the CT and the CFU milliliter-1 of the starting quantity of E. coli O157:H7 DNA. A detection limit of 7.9 x 10-5 pg of starting DNA ml-1, equivalent to 6.4 x 103 CFU ml-1, was determined. The efficiency of each assay was calculated from the slope of the standard curve. The standard curves generated from the PCR data resulted in reaction efficiencies of 93.6, 99.9, and 99.6% for the stx2, stx1, and eae genes, respectively, with correlation coefficients of 0.96, 0.99, and 0.98, respectively (Fig. 2 has data for the eae gene).
![]() View larger version (18K): [in a new window] |
FIG. 2. Standard curve for the real-time PCR analysis of E. coli O157:H7 strain 3081. The CT values are plotted against the corresponding E. coli O157:H7 DNA concentrations. Template DNA was extracted from E. coli O157:H7 DNA, diluted 10-fold, and used as a known DNA concentration in every experiment. DNA was extracted from E. coli O157:H7 strain 3081 in amounts between 6.4 x 10-2 and 6.4 x 108 CFU ml-1. The reaction efficiencies of the stx1 and eae genes were above 99%, while that of the stx2 gene was about 93%.
|
5% from the CT values generated in the multiplex PCR containing all three primer-probe sets (Fig. 3). Under these optimized conditions, the linearity between the CT values and the target concentrations was observed between 3.5 x 103 (stx1), 3.5 x 104 (stx2 and eae), and 3.5 x 108 CFU ml-1 dilutions of E. coli O157:H7. This demonstrates that quantification of target DNA was possible within this range. The detection sensitivity in soils spiked with 10-fold serial dilutions of E. coli O157:H7, therefore, ranged between 3.5 x 103 CFU ml-1 and 3.5 x 108 CFU ml-1 for the stx1 gene (Fig. 3A) and 3.5 x 104 CFU ml-1 and 3.5 x 108 CFU ml-1 for the stx2 and eae genes (Fig. 3B and C).
![]() View larger version (18K): [in a new window] |
FIG. 3. Determination of detection limits between the single reactions and the multiplex reactions in spiked soil. Standard curves for multiplex versus single-gene real-time PCR analysis of E. coli O157:H7 are shown for the three genes. A linear relationship was maintained between 6.4 x 103 and 6.4 x 108 CFU g-1 for the stx1 gene (A) and 6.4 x 104 and 6.4 x 108 CFU g-1 for the stx2 gene and the eae gene, respectively (B and C, respectively).
|
The detection of very low levels of bacterial contamination in soils and feces requires that the samples be cultured for a few hours in an appropriate enrichment broth. Enrichment dilutes out the inhibitory substances and provides conditions conducive to the growth and multiplication of bacterial pathogens to a detectable number. Plotting the mean CT values against the starting quantities of DNA generated the standard curve that was used to estimate E. coli O157:H7 concentrations in spiked soil samples (Fig. 4). The multiplex PCR assay allowed detection of 1.58 x 107, 7.52 x 106, and 4.96 x 106 CFU of E. coli O157:H7 g-1 in soil with the stx1-, stx2-, and eae-specific primer-probe sets, respectively, from soil spiked with 3.5 x 108 CFU of E. coli O157:H7 strain 3081 g-1 (data not shown). The detection limit of this PCR assay in soil samples without enrichment (0 h) was 3.5 x 104 CFU g-1. At this concentration, the assay efficiencies were within 5% of each other and were within the linear range of the standard curve. The concentrations were equivalent to 4.10 x 104, 4.88 x 104, and 4.85 x 104 CFU of E. coli O157:H7 g-1 based on detection of the stx1, stx2, and eae genes, respectively. After 2 h of enrichment, the assay detected 6.7 x 103 CFU g-1 on the average for the three genes when the soil was spiked with 100 CFU of E. coli O157:H7 ml-1 (Fig. 5). After 8 h, the soil samples spiked with 1 CFU ml-1 resulted in the detection of 1.60 x 105 CFU g-1 on the average for the three genes and 1.15 x 106 CFU g-1 when 100 CFU ml-1 was used as the inoculum density. By using a single enrichment process, the real-time PCR assay detected between 1 and 10 CFU of E. coli O157:H7 g-1 after 16 h of enrichment in artificially inoculated soils. The presence of heterotrophic bacterial flora at a level of 107 CFU g of soil-1 before enrichment had no effect on the detection sensitivity of this assay (data not shown). The detection sensitivity obtained in this assay was comparable to that of conventional multiplex PCR methods (13). The use of enrichment along with the real-time PCR approach described here offers the possibility for sensitive detection of E. coli O157:H7 in soil within 1 day. This approach has successfully been used for relative quantification of E. coli O157:H7 in other matrices (3, 21, 28).
![]() View larger version (20K): [in a new window] |
FIG. 4. Standard curves for multiplex real-time PCR analysis of E. coli O157:H7 in spiked soil. The reaction efficiencies for the stx1 and eae genes were higher than that for the stx2 gene as demonstrated by the closeness of the standard curves. These standard curves were used for the detection and quantification of E. coli O157:H7 from the enrichment experiment.
|
![]() View larger version (29K): [in a new window] |
FIG. 5. Detection and quantification of E. coli O157:H7 in soil spiked with different concentrations of pathogens and after 0 to 16 h of enrichment. The sensitivity of the multiplex PCR assay from the standard curve in Fig. 4 was used for the detection and quantification of the stx1 and stx2 genes of STEC and the eae gene of E. coli O157:H7 in spiked soil. Concentrations shown are for samples collected after incubation times of 0, 2, 8, and 16 h. Standard errors were derived from the means of triplicate data points.
|
|
View this table: [in a new window] |
TABLE 4. Concentrations of total E. coli and E. coli O157 detected in environmental samples by culture methods
|
![]() View larger version (23K): [in a new window] |
FIG. 6. Standard curves for the multiplex real-time PCR analysis of E. coli O157:H7 from calf and cow feces, manure, and wetlands wastewater. E. coli O157:H7 concentrations were determined for the samples collected in August and September. Similar curves were done for December, February, April, and July.
|
|
View this table: [in a new window] |
TABLE 5. Concentrations of E. coli O157:H7 detected in environmental samples by real-time PCR
|
The automated PCR amplification and detection of target gene amplicons described in this study are conducive for screening large numbers of environmental samples in a single assay. This method is a significant tool for monitoring large numbers of environmental samples contaminated with cattle feces or manure that are subsequently transported either by horizontal flow to larger bodies of water or by vertical movement to groundwater. This problem is critical in the Chino-Santa Ana River Basin, Calif., where the surface water and groundwater are major sources of drinking water and where the water quality is progressively deteriorating due to intensive dairy operation and disposal of untreated wastewater into the Chino Basin. The use of constructed wetlands in treating wastewater from farm operations may improve the quality of water that drains into the Santa Ana River. The multiplex PCR assay in combination with culture methods can be a useful method for water districts in the area to monitor contamination by this pathogen in the major rivers and groundwater.
|
View this table: [in a new window] |
This research was supported by the 206 Manure and By-Product Utilization Project of the USDA-ARS.
Mention of trademark or proprietary products in this work does not constitute a guarantee or warranty of the property by the USDA and does not imply its approval to the exclusion of other products that may also be suitable.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»