Previous Article | Next Article ![]()
Applied and Environmental Microbiology, November 2003, p. 6597-6604, Vol. 69, No. 11
0099-2240/03/$08.00+0 DOI: 10.1128/AEM.69.11.6597-6604.2003
Copyright © 2003, American Society for Microbiology. All Rights Reserved.
Gerda Harms,1 Alice C. Layton,1,2 Igrid R. Gregory,1 Jack Parker,1,3 Shawn A. Hawkins,1,3 Kevin G. Robinson,1,3 and Gary S. Sayler1,2*
Center for Environmental Biotechnology,1 Department of Microbiology,2 Department of Civil and Environmental Engineering, The University of Tennessee, Knoxville, Tennessee 379963
Received 28 February 2003/ Accepted 9 June 2003
|
|
|---|
|
|
|---|
Bacteria are the major component of activated sludge and are responsible for the oxidation of organic matter and nutrient transformations, as well as the production of polysaccharides and other polymeric materials that aid in the flocculation of the microbial biomass (3). Although the activated sludge system is the most widely used biological process for the treatment of wastewaters, the achievement of reliable high-quality effluent is still elusive, as upsets in plant performance are frequent. Changes in the microbial population of the mixed liquor can lead to significant process problems, such as bulking, foaming, or failure in nitrification (25, 32). Yuan and Blackall (38) recently proposed optimization of the sludge population for control of biological wastewater treatment systems to ensure consistent long-term performance. Real-time PCR provides the opportunity to quantify such changes in individual populations within the sludge under different operational conditions or influent compositions. However, it is important to understand the limitations of real-time PCR assays, particularly the ability to discriminate changes in the microbial population, given the inherent variability in the real-time PCR assay and DNA extraction and recovery between samples.
DNA extraction from activated sludge has been performed for two decades for DNA probing, PCR amplification of specific targets, and the construction of clonal libraries. For these purposes, sample lysis needs to be complete without excessive shearing of the DNA, which can increase artifact formation during the PCR (31). The extracted nucleic acid must be free of contaminants that can inhibit enzymes used in subsequent molecular techniques, such as restriction endonucleases or Taq polymerase (1, 34). For quantitative studies of mixed-liquor population dynamics using real-time PCR, the DNA extraction method also needs to provide uniform DNA recovery and high throughput. Real-time PCR allows the simultaneous quantification of at least 24 samples in 1 to 2 h (in a 96-well format, considering triplicate measurements plus standards and controls). In this study, the performance of a commercially available DNA extraction kit with a rapid vertical angular motion, matrices, and chaotropic reagents to lyse the cells, followed by a GENECLEAN procedure for DNA purification, was tested in mixed-liquor samples and applied towards real-time PCR analysis.
The PCR aspects of the real-time PCR assay are also sources of variability in the quantification of a specific target in an environmental sample. PCR variability may be higher for a less-abundant target than a more-abundant target. Therefore, in this study the variability of a highly abundant biomass target (bacterial 16S rRNA gene) and a less-abundant target of bacteria subject to clustering within the activated sludge matrix (Nitrospira 16S rRNA gene [12, 26, 33]) was determined. All factors contributing to the final assay variability will influence the number of samples necessary to achieve a certain statistical power (18). Power analysis was performed using SamplePower 2.0 to determine the minimum number of samples required to differentiate between 2-, 5-, and 10-fold changes in microbial populations within activated sludge with low and high biomass (MLVSS).
|
|
|---|
DNA extractions.
Total DNA was extracted in triplicate from mixed-liquor suspended solids using a FastDNA kit (Q-BIOgene, Carlsbad, Calif.) with minor modifications (13). The volume of mixed liquor used for each extraction was 1 ml for 10- and 20-day SRT samples, 2.5 ml for 5-day SRT samples, and 5 ml for 2-day SRT samples. These volumes corresponded to 1.2 to 2.6 mg of MLVSS per extraction for all analyzed samples. CLS-TC cell lysis-DNA solubilizing solution for bacteria, a 1/4-inch ceramic sphere, and the garnet matrix (Q-BIOgene) were used for cell lysis. The sample was homogenized using a 20-s pulse at a speed of 4.0 (FastPrep FP120; Q-BIOgene). After centrifugation to pellet debris, the lysate supernatant was combined with the binding matrix (600 µl) and gently mixed at room temperature for 5 min. SPIN modules (Q-BIOgene) were used for washing and eluting the DNA. Two washes of the binding matrix-DNA complex using 80% (vol/vol) ethanol were included after the recommended salt-ethanol wash step. For elution, the matrix-DNA complex was resuspended in 100 µl of 10 mM Tris-HCl (pH 8.0) buffer, incubated for 5 min at room temperature, and centrifuged for 1 min at 14,000 x g. The elution was repeated for a final volume of 200 µl.
Purity and yield of DNA.
The purity of the extracted DNA was assessed spectrophotometrically by calculating A260/A280 ratios in a Beckman DU640B spectrophotometer (Beckman Instruments Inc., Fullerton, Calif.). DNA was quantified using a PicoGreen double-stranded-DNA quantitation kit (Molecular Probes, Eugene, Ore.) with lambda DNA as the standard, following the manufacturer's instructions. DNA yields were calculated in micrograms of DNA extracted per liter of mixed liquor or per milligram of MLVSS.
Bacterial 16S ribosomal DNA and Nitrospira 16S ribosomal DNA real-time PCR.
Bacterial and Nitrospira 16S rRNA gene quantifications were performed in a total volume of 25 µl with Platinum Quantitative PCR SuperMix-UDG (Life Technologies, Inc., Gaithersburg, Md.) and 5 mM MgCl2 as previously described (21). The Nitrospira primers and probe have no mismatches to a range of Nitrospira 16S rRNA genes isolated from activated sludge including clones in the clade 2 group (7), clones A-4 and A-11 (26), and clones in the b2-b37 cluster (33). The Nitrospira 16S rRNA gene assay contained 15 pmol of primers NSR1113f (5'-CCTGCTTTCAGTTGCTACCG-3') and NSR1264r (5'-GTTTGCAGCGCTTTGTACCG-3'), 6.25 pmol of TaqMan probe NSR1143fTaq [5'-(6-carboxyfluorescein)-AGCACTCTGAAAGGACTGCCCAGG-(carboxytetramethylrhodamine)-3'], and 0.32 to 1.54 ng of sample DNA or 30 to 3 x 107 copies of the standard (151-bp fragment of Nitrospira 16S rRNA gene; GenBank accession number AF420301). PCR amplification consisted of 2 min at 50°C, 10 min at 95°C, and 55 cycles at 95°C for 30 s and 63°C for 60 s. For the total bacterial 16S rRNA gene assay, the general bacterial primers and probes were derived from broad-specificity 16S rRNA gene primers (30). This assay contained 15 pmol of primers 1055f (5'-ATGGCTGTCGTCAGCT-3') and 1392r (5'-ACGGGCGGTGTGTAC-3'), 6.25 pmol of TaqMan probe 16STaq1115 [5'-(6-carboxyfluorescein)-CAACGAGCGCAACCC-(carboxytetramethylrhodamine)-3'], and 0.32 to 1.54 ng of sample DNA or 4.5 x 103 to 4.5 x 108 copies of the same plasmid used for the Nitrospira 16S rRNA gene assay. The PCR program consisted of 2 min at 50°C, 10 min at 95°C, and 45 cycles at 95°C for 30 s, 50°C for 60 s, and 72°C for 20 s. All samples were measured three to six times during each assay, and negative controls without template were included in each PCR run. Amplification and detection were performed using the DNA Engine Opticon continuous fluorescence detection system (MJ Research, Waltham, Mass.) or the Bio-Rad iCycler with the iQ fluorescence detector and software version 2.3 (Bio-Rad, Hercules, Calif.). Gene copies per PCR for both assays were calculated using the same universal standard curve generated from 33 individual standard curves (gene copies = power {10, [(-0.24 x CT) + 10.7]}) (CT, threshold cycle). Copies of both targets per liter of mixed liquor and per microgram of DNA were calculated considering the volume of mixed liquor used for each DNA extraction, the volume of DNA added to each PCR, and the concentration of DNA.
Statistical analysis.
All statistical analyses were performed using SPSS version 11.0 and SamplePower 2.0 (SPSS Inc., Chicago, Ill.). Data were normally distributed, and a one-way analysis of variance (ANOVA) test was performed after log10 transformation of the data to meet the assumption of equal variance between groups. In ANOVA tests, the mean difference was significant at the 0.05 level. Multiple comparisons were performed with the Tukey honestly significant difference and Bonferroni tests. The correlation between variables was analyzed using the bivariate two-tailed Pearson correlation. SamplePower 2.0 was used for power analysis to determine the number of samples necessary in each of the two groups being compared. Power analyses were conducted using one-way ANOVA comparisons, a significance level of 0.05, and a power of 80%.
|
|
|---|
DNA yields (micrograms of DNA/liter of mixed liquor) and MLVSS values were related with an excellent fit to a sigmoid curve (Fig. 1A) (r2 = 0.973). Using mixed-liquor extraction volumes of 5 ml, samples from the 2-day SRT reactor yielded 2.39 ± 0.25 µg of DNA. A volume of 2.5 ml was used in each DNA extraction for 5-day SRT reactor samples, with a yield of 2.37 ± 0.54 µg of DNA. One milliliter of sample from 10- and 20-day SRT reactors yielded an average of 4.02 ± 0.78 and 5.35 ± 0.25 µg of DNA, respectively. No significant differences in micrograms of DNA per milligram of MLVSS were found in pairwise comparisons of 2- and 5-day reactor samples (low biomass) or 10- and 20-day SRT samples (high biomass) (one-way ANOVA, posthoc multiple comparisons; P > 0.05), although differences in DNA yield between the low- and high-biomass reactor samples were significant.
![]() View larger version (19K): [in a new window] |
FIG. 1. (A) Influence of MLVSS values on DNA yields (expressed in micrograms of DNA per liter [L] of mixed liquor). DNA yields from mixed-liquor samples obtained from bench scale reactors operating at different SRTs were fit to a three-parameter sigmoid curve (f = a/{1 + exp[-(X - X0)]/b}) (r2 = 0.973). (B) Influence of the amount of biosolids used in each extraction on DNA yields (expressed in micrograms of DNA per milligram of MLVSS) (y = 3.393 - 0.73x) (r2 = 0.126). The dashed lines represent the 99% confidence interval. Error bars indicate the standard deviation of DNA yields for each triplicate extraction.
|
Quantification of bacterial and Nitrospira 16S rRNA genes.
Real-time PCR assays were used to quantify bacterial and Nitrospira 16S rRNA genes in DNA extracts from mixed-liquor samples. Bacterial 16S rRNA genes were used as a measurement of total biomass, since a large fraction of the biosolids in mixed liquor are bacteria. As found with DNA yields, bacterial 16S rRNA genes per liter increased with longer retention times in the bench-scale reactors, from approximately 2.9 x 1011 to 3.2 x 1012 copies/liter of mixed liquor for 2- and 20-day reactor samples, respectively (Fig. 2A). One-way ANOVA indicated significant differences in pairwise comparisons of bacterial 16S rRNA genes per liter in all four reactors (P < 0.05). In addition, MLVSS values and bacterial 16S rRNA genes per liter of mixed liquor were significantly correlated (r = 0.951). When normalized to micrograms of DNA, the mean bacterial 16S rRNA gene copy number remained stable through all 36 extractions at 6.24 (±1.64) x 108 (Fig. 2B). No significant differences were observed between reactors in pairwise comparisons of bacterial 16S rRNA genes per microgram of DNA (P > 0.05), with the exception of samples from 5- and 10-day reactors.
![]() View larger version (62K): [in a new window] |
FIG. 2. Quantification of total bacterial 16S rRNA genes (A and B) and Nitrospira 16S rRNA genes (C and D) using real-time PCR in reactors operating at 2-, 5-, 10-, and 20-day SRTs. Separate extractions are indicated with black, white, and diagonal bars (Average ± standard deviation of three determinations). Targets are expressed in copies/liter (L) of mixed-liquor (A and C) or copies/microgram of DNA (B and D). The detection limits for the bacterial 16S rRNA and Nitrospira 16S rRNA genes were 3.6 x 109 copies/liter and 1.0 x 107 copies/liter, respectively, and 1.5 x 107 copies/µg of DNA and 4.2 x 104 copies/µg of DNA, respectively.
|
When Nitrospira 16S rRNA genes were normalized to micrograms of DNA (Fig. 2D), no significant differences were found between the reactors (one-way ANOVA; F = 1.675), suggesting that differences in the number of Nitrospira 16S rRNA genes per liter between the reactors were biomass dependent. The correlation between biomass (MLVSS) and Nitrospira 16S rRNA genes per liter of mixed liquor (r = 0.525) was less than that for the total bacterial 16S rRNA genes (r = 0.951).
The percentage of Nitrospira cells in the total bacterial population was estimated assuming an average of 3.6 ribosomal operons per bacterial cell and 1 ribosomal operon copy per Nitrospira cell (21). Based on these assumptions, Nitrospira was estimated to be 2.5% ± 1.1% of the total bacterial population in the 2-day reactor, 2.4% ± 2.0% in the 5-day reactor, 4.3% ± 2.0% in the 10-day reactor, and 1.5% ± 0.77% in the 20-day reactor.
Variability and power analyses.
The variability in DNA extraction yields and in bacterial and Nitrospira 16S rRNA gene quantification assays were evaluated to identify the main sources of error for estimating bacterial and Nitrospira 16S rRNA genes in activated sludge. In real-time PCR assays, the threshold cycle (CT), or the PCR cycle at which the fluorescent signal is statistically significant above background, is measured (8). The CT value is compared to a standard curve generated with known target concentrations in order to estimate sample copy concentration. The variability of the real-time PCR assays was studied in both steps in the quantification of the target, CT values and copies of the target.
The coefficient of variation (CV) (standard deviation expressed as a percentage of the mean) of DNA yields (micrograms of DNA per milligram of MLVSS) in the 12 triplicate extractions was 12.2% (Table 1). CVs were calculated per sample (variability of average values per sample for each of the 12 samples) and per DNA extraction (CV of triplicate measurements of the real-time PCR assay in each of the 36 DNA extractions). The CVs of the CT values for bacterial and Nitrospira 16S rRNA genes were similar (Table 1). However, the CVs of the Nitrospira 16S rRNA genes per liter of mixed liquor were approximately 1.5 times higher than the corresponding CVs for bacterial 16S rRNA genes per liter of mixed liquor. These results suggest that the observed error is mainly attributable to the real-time PCR rather than differences in DNA extraction efficiencies.
|
View this table: [in a new window] |
TABLE 1. Variability in quantification of bacterial and Nitrospira 16S rRNA gene targets in mixed-liquor samples by real-time PCR
|
|
View this table: [in a new window] |
TABLE 2. Power analysis predictions for sample size required to detect 2-, 5-, and 10-fold differences in bacterial and Nitrospira 16S rRNA gene copies per litera
|
Variability associated with real-time PCR.
In order to confirm the variability in quantification of a low-copy-number target by real-time PCR, aliquots of a single DNA extract from the 10-day SRT reactor were spiked with plasmid DNA containing the Nitrospira 16S rRNA gene to produce samples with approximately 2-, 5-, and 10-times-higher concentrations of Nitrospira 16S rRNA genes. The unspiked and spiked DNA mixtures were assayed for Nitrospira 16S rRNA genes on five separate days. On each day, the samples were run in triplicate to compare variability within a PCR assay and between PCR assays performed on different days (Table 3). The mean coefficient of variation between PCR assays (37.5%) was twice as high as the coefficient of variation within a PCR assay (16.8%). Based on the copies per liter in the unspiked (1x) sample and the volumes of plasmid DNA added to the DNA extract, the increase in Nitrospira 16S rRNA gene copies relative to the unspiked sample were expected to be 2.4, 4.1, and 7.9 fold. The calculated fold increases compared to the 1x sample were 1.41 (±1.25), 3.92 (±2.19) and 6.84 (±4.53). The data in copies per liter were compared with a one-way ANOVA to determine which mixtures were significantly different (P < 0.05). In these analyses, significant P values were obtained in samples differing by 2.8 or more (1x versus 5x, 1x versus 10x, 2x versus 5x, and 2x versus 10x) but not in samples differing by 1.7 or less (1x versus 2x and 5x versus 10x). These results support the power analyses indicating that more than five samples are needed to resolve twofold differences by the Nitrospira 16S rRNA gene assay.
|
View this table: [in a new window] |
TABLE 3. Nitrospira 16S rRNA genes per liter in a DNA sample spiked with a plasmid containing a Nitrospira 16S rRNA gene
|
|
|
|---|
Variations in cell lysis, DNA binding to the matrix, and DNA elution can contribute to differences in the DNA recovery. In order to improve the binding of the DNA to the matrix, the crude lysate was continuously mixed with the matrix during the recommended 5-min incubation, and the elution of the DNA was performed in two steps to increase the DNA recovery. In addition, since the silica matrix binding and elution properties vary with pH (low pH promotes DNA binding, high pH favors dissociation), 10 mM Tris-HCl (pH 8.0) was used for the elution step. This buffer also increases the stability of the extracted DNA and does not interfere in the PCR, compared with water or Tris-EDTA. DNA yields ranged from 443 to 5,633 µg/liter of mixed liquor and, as expected, increased with increasing MLVSS values (Fig. 1A). These yields were approximately 25-fold lower than those found by Bourrain et al. (4) using phenol-chloroform extraction protocols for extracting DNA from activated sludges and threefold lower than those reported by Yu and Mohn (37). However, the difference in the yield may be related to the method used for the quantification of the DNA, since absorbance at 260 nm can easily overestimate the DNA concentration due to its inability to distinguish between DNA and RNA, and the relative insensitivity of this assay compared to the PicoGreen assay.
Overall, DNA extraction had a smaller effect on total assay variability than PCR, as evidenced by the lower CVs in Table 1 and the similar number of samples predicted for three extractions versus one extraction by power analyses in Table 2. This suggests that the overall assay variability may be due to variability in the real-time PCR. The mean CV of the CT values for triplicate measurements of the real-time PCR assay was 1.9% for both bacteria and Nitrospira 16S rRNA genes (Table 1) and is consistent with 2% CVs reported for TaqMan assays with clinical as well as environmental samples (16, 22, 24). However, low CVs in CT values correspond to considerably higher CVs when linear CT values are converted to exponential copies of the target per liter of mixed liquor (Table 1).
The variability associated with the quantification of a target by real-time PCR is of particular concern when low-target concentrations relative to nontarget DNA (10), such as Nitrospira 16S rRNA genes, are considered. In this study, Nitrospira 16S rRNA genes were approximately 100-fold less abundant than total bacterial 16S rRNA genes. In addition, the concentrations of Nitrospira in reactors with different SRTs are of interest because Nitrospira is considered the primary organism responsible for nitrite oxidation in activated sludge. Reported percentages for Nitrospira by in situ hybridization in a sludge from an industrial plant connected to a rendering factory were 9 and 12% (26, 27), 2.5% for a combined activated sludge-rotating biological contactor process (36), and less than 5% for another rotating biological contactor (15). For comparison purposes, the percentages of Nitrospira for these current reactors under study were calculated assuming 1 ribosomal operon copy per Nitrospira cell and 3.6 ribosomal operon copies per general bacterial cell. Based on these assumptions, the percentages of Nitrospira ranged from 1.5 to 4.3% and were lower than those found in a municipal wastewater treatment plant (8.6%) using the same Nitrospira assay (21). However, these percentages can only be considered an estimate, because the number of ribosomal operons in bacteria can range from 1 to 15 (29). In addition, it is hypothesized that bacteria with short doubling times have more ribosomal operons per cell than bacteria with longer doubling times (28). Therefore, bacteria in the 2-day SRT reactor may have a larger number of ribosomal operons per cell than those in the 20-day SRT reactor. Although the calculated percentage of Nitrospira was similar for all four reactors, the total numbers of Nitrospira cells (assuming 1 ribosomal operon copy per cell) were 6- to 10-fold higher in the two reactors (10- and 20-day) with complete nitrification than in the 2-day SRT reactor with incomplete nitrification due to the higher biomass in the 10- and 20-day SRT bioreactors.
The overall variability in this set of extractions was used in power analyses to estimate the number of samples necessary to find statistically significant changes in the microbial population. Essentially, the larger the group sample size, the greater the power of the statistical test and the more sensitive the experiment would be in detecting differences in microbial populations in the activated sludge under different operational conditions (18). Several power analyses were performed to determine the contributions of DNA extraction, PCR assay, and differences in starting biomass to the number of samples needed to detect 2-, 5-, and 10-fold changes (Table 2). With regard to the power analyses, two observations can be made. First, a 2-, 5-, or 10-fold change should be detected by the 16S rRNA gene assay, representing the high target gene, using a sample size of three to five size regardless of the biomass concentration and number of sample extractions performed. In contrast, the number of samples needed to reliably detect a twofold change with the Nitrospira 16S rRNA gene assay, representing the low target gene, was higher and differed between the high-biomass (7 samples) and low-biomass (22 samples) data (Table 2). However, a 5- or a 10-fold difference would be resolvable by the Nitrospira 16S rRNA gene assay using three samples for the high-biomass data or five samples for the low-biomass data. This suggests that for assays with high-variability and low-abundance genes, either more samples need to be analyzed or larger changes need to occur in the population in order to reliably interpret twofold or lower variation in the microbial population.
Second, only a slight increase in the number of samples per group was required to obtain 80% power when one versus three DNA extractions per sample were considered (Table 2). Therefore, increasing the number of real-time PCR assays performed with a single DNA extract may have as large an effect on statistical power as increasing the number of DNA extractions and real-time PCR assays performed with each activated sludge sample. The interassay variability attributable to the PCR assays was further demonstrated by comparing variability within a single PCR run and between PCR runs using a single DNA extract spiked with Nitrospira 16S rRNA genes. In this experiment, the CVs within a PCR run were approximately one-half those between PCR runs, 16.8% versus 37.5%. Five separate PCR runs were sufficient to detect statistically significant differences in the samples differing in Nitrospira 16S rRNA genes by about fourfold and sevenfold but not less than twofold.
The development of real-time PCR assays for critical microbial populations found in wastewater treatment systems may increase our understanding of microbial population dynamics in activated sludge and potentially influence the design and operation of wastewater treatment plants in the future. However, it is important to recognize the limitations of any new technique, particularly when applied to environmental samples. In order to increase the statistical power, for low-template, high-background DNA situations, it is necessary to increase the sample size or to reduce the variability of the real-time PCR assay. The variability in CT values and thus copies per PCR may be reduced by continuing improvements in the design and optimization of the real-time PCR assays, improvements in commercial reagents, automatization of both the DNA extraction and the dispensing of reagents (9), and the use of internal controls to account for differences in lots of probes, master mixes, and sets of standards. Such improvements may ultimately reduce the number of samples needed to resolve small differences (<2-fold) in gene populations within complex mixtures.
We thank the Knoxville Utility Board for access to the wastewater treatment plant and Mike Newman from the statistical consulting center, University of Tennessee, for his advice on statistical analysis of the data.
Present address: CENPAT-CONICET, Puerto Madryn, Chubut, Argentina. ![]()
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»