Previous Article | Next Article ![]()
Applied and Environmental Microbiology, June 2003, p. 3158-3164, Vol. 69, No. 6
0099-2240/03/$08.00+0 DOI: 10.1128/AEM.69.6.3158-3164.2003
Copyright © 2003, American Society for Microbiology. All Rights Reserved.
National Exposure Research Laboratory, Office of Research and Development,1 Technical Support Center, Office of Water, U.S. Environmental Protection Agency, Cincinnati, Ohio 452682
Received 7 August 2002/ Accepted 19 March 2003
|
|
|---|
|
|
|---|
Enteric viruses can move from sources of contamination, such as broken sewage pipes and septic tanks, into groundwater aquifers (24). Viruses are typically detected in contaminated waters by concentrating virus particles from large volumes of water on positively charged filters (12, 29). Viruses normally are eluted from the filters with beef extract, which is further concentrated from the eluate by organic flocculation. Viruses present in the concentrate often are detected with plaque or quantal cell culture assays (2, 11, 12). These cell culture analytical methods are labor intensive, requiring about 1 week to more than 6 weeks. Moreover, these methods detect primarily enteroviruses and reoviruses (12). Environmental isolates of many other virus groups are difficult to culture, and Norwalk-like caliciviruses cannot be propagated in established cell lines.
The reverse transcription-PCR (RT-PCR) method is flexible enough to detect all waterborne human enteric viruses. However, there have been two major obstacles to the use of RT-PCR for the detection of viruses in environmental waters: (i) the presence of inorganic and organic inhibitors of the enzymes that are used to amplify viral genomes in environmental samples (15, 27) and (ii) the very small volume that can be assayed in an RT-PCR, typically representing <1 liter to about 10 liters of the original water sample filtered for virus analysis (1, 2). The small volume assayed may lead to false-negative samples because virus titers in contaminated water are often very low.
The U.S. Environmental Protection Agency (EPA) conducted a national groundwater survey for viruses in response to comments received at an informational meeting held in 1990 on a proposed Groundwater Disinfection Rule. The design of the study, the physicochemical characteristics of the sites, and the results of fecal indicator and virus culture assays have been published previously (7, 19, 30). In the present report, we describe the application of a new procedure for the removal of inhibitors of amplification from groundwater samples and a new multiplex RT-PCR assay for human enteric viruses. The major advantages of these procedures are that they result in excellent virus recovery while providing a large additional concentration of virus in the sample and reduce the number of RT-PCR assays that must be performed on each water sample.
|
|
|---|
Reovirus type 3 was grown in Buffalo green monkey (BGM) kidney cells, and the virus was released by three freeze-thaw cycles. Following removal of cell debris by centrifugation at low speed, the stock preparation containing 2 x 107 PFU/ml was stored at -70°C. A working stock was prepared by diluting the stock preparation 1:100 in PBS with 0.1% BSA. Aliquots of the working stock were then stored at -70°C.
Rotavirus (Wa strain) was grown on MA104 cells, and the virus was released by three freeze-thaw cycles. Following removal of cell debris by centrifugation at low speed, the stock preparation containing 2,000 PFU/ml was stored at -70°C. A working stock was prepared by diluting the stock preparation 1:100 in PBS with 0.1% BSA. The working stock was stored in aliquots at -70°C.
A stock preparation of hepatitis A virus (HAV) strain HM-175 was obtained from Mark D. Sobsey, University of North Carolina. The preparation had been grown on BS-C-1 cells and determined to contain 1.9 x 106 radioimmunofocus units (RFU)/ml. The virus was diluted to 250 RFU/µl in PBS with 0.1% BSA and stored in aliquots at -70°C.
Norwalk virus was prepared by extracting a 10% suspension of a Norwalk virus-positive stool specimen (in PBS with 0.1% BSA) with an equal volume of trichlorofluoroethane (DuPont; this reagent is no longer available, but current alternatives should be adequate [22]). The stool specimen was from a volunteer study funded by the National Marine Fisheries Service and kindly provided by Gary Richards (Charleston Laboratory, National Marine Fisheries Service). Extracted virus was stored at 4°C and diluted in PBS with 0.1% BSA just prior to assay.
Virus mixtures used in multiplex RT-PCRs.
The molecular titer of each virus stock was measured in terms of RT-PCR units by performing single-virus RT-PCR assays (see below) on 10-fold serial dilutions of each stock. One unit is the amount of virus present in the highest dilution that gives a positive result. A mixture of poliovirus, reovirus, and rotavirus was prepared by mixing 10 µl of working stocks of each virus with 70 µl of PBS with 0.1% BSA. This mixture, designated virus mixture A, was prepared, aliquoted, and stored at -70°C. A mixture of HAV and Norwalk virus was prepared for use in RT-PCRs designed to detect these viruses by mixing 10 µl of HAV working stock and 10 µl of a 10-3 dilution of Norwalk virus with 80 µl of PBS and 0.1% BSA. This mixture, designated virus mixture B, was prepared, aliquoted, and stored at -70°C. Virus mixture A and B preparations were rapidly thawed and used at a 10-1 dilution in RT-PCR assays. This dilution gives a final concentration of 50 to 100 RT-PCR units per reaction for each virus.
Groundwater samples.
Each groundwater sample was collected for virus analyses by passing water through a positively charged 10-in. Zetapor 1MDS cartridge filter (Cuno catalog no. 45144-01-1MDS) placed in a standard filter apparatus. The standard filter apparatus consisted of a backflow regulator, a pressure regulator and gauge, a 10-in. cartridge housing containing the 1MDS filter, a water meter, and a flow control valve. The pressure regulator was set at 207 kPa, and the flow control valve was set at 11.4 liters/min. The standard filter apparatus was cleaned and sterilized prior to each use. Samplers were trained for sample collection through the use of a virus sampling training video. Large water samples were typically collected by allowing water to run through the sampling apparatus overnight and then shipped by overnight courier to the analysis laboratory.
Virus was eluted from each 1MDS filter with a modification of the celite elution procedure of Dahling and Wright (7, 8). Briefly, two elutions were performed with 1,600 ml of 1.5% powdered beef extract (Adams Scientific catalog no. 4900-107), pH 9.5. The first elution was performed immediately on receipt of a sampling apparatus. The second elution was performed by storing the cartridge housing filled with 1.5% beef extract overnight at room temperature prior to elution. Viruses present in each sample eluate were concentrated by the addition of 1.6 g of celite (Ohio Valley Specialty Chemical catalog no. MCAFA), adjustment of the pH to 4.0, stirring for 10 min at room temperature, and collection of the celite onto sterile 75-cm-diameter prefilters (Millipore Corporation catalog no. AP20 075 00) by vacuum filtration. Adsorbed viruses were eluted by allowing 80 ml of 0.15 M sodium phosphate, pH 9.0 to 9.5, to filter through the celite with no vacuum. For each groundwater sample to be analyzed by RT-PCR, 20 ml each of the first and second celite eluates was mixed and stored at -70°C.
Inhibitor removal procedure.
On the day before the day on which samples were to be processed, SW28 ultracentrifuge tubes (Beckman catalog no. 344058) and Microcon-100 units (Millipore catalog no. 42414) were filled with PBS containing 0.2% BSA (crystalline grade) and soaked overnight at 4°C. On the day of processing, the groundwater molecular subsamples were rapidly thawed. Following the addition of 80 µl of 5% BSA, the viruses present in 32 ml of each subsample was pelleted through a 5-ml pad of 30% sucrose in 20 mM Tris-1 M NaCl-1 mM EDTA-5 mM EGTA-0.1% crystalline BSA at 131,000 x g for 4.5 h at 10°C. The supernatants were immediately aspirated at the end of the run, and the pellets were resuspended in 2 x 100 µl of PBS with 0.2% BSA.
Each resuspended ultracentrifuge pellet was extracted with 200 µl of 0.01% dithiozone (diphenyl thiocarbazone; Fisher catalog no. D90)-0.01 M 8-hydroxyquinoline-butanol-methanol-trichloroethane (0.1/0.9/1/0.25/0.25, vol/vol). The mixture was prepared fresh with each use with stock solutions of 0.01% dithiozone and 0.01 M 8-hydroxyquinoline (Fisher catalog no. 0261) in chloroform. Stock solutions were stored for up to 1 month at 4°C. Following the addition of the chemical-solvent mixture, samples were vortexed for 30 s, allowed to sit for 15 s at room temperature, vortexed for another 30 s, allowed to sit for another 30 s, and then centrifuged at 14,000 x g in a microcentrifuge for 5 min at 4°C. The aqueous layer was removed and concentrated in a Microcon-100 unit as described by the manufacturer. Samples were washed with 80 µl of PBS-0.2% BSA, reconcentrated to a total volume of about 40 µl, frozen, and then stored at -70°C until assayed by RT-PCR.
Percent recovery of virus during the inhibitor removal procedure.
Negative celite extracts were prepared by adding celite to sterile beef extract as described above. Following pH adjustment and stirring for 10 min, the celite was collected on prefilters. Sodium phosphate, pH 9.0 to 9.5, was passed through the celite and then adjusted to pH 7.0 to 7.5. Thirty-two-milliliter volumes of negative celite extracts were seeded with 50 PFU of poliovirus and run through the inhibitor removal procedure to determine virus recovery. Percent virus recovery was calculated from the amount of virus recovered in the entire 40-µl concentrated sample and the amount of virus in the seed, as measured by plaque assay (11).
Laboratory-derived celite extracts were also seeded with 400 to 1,400 RT-PCR units of each virus and run through the inhibitor removal process. The concentrated sample and sample diluted 10- and 100-fold were assayed by RT-PCR 2-µl assay volumes as described below.
Oligonucleotide primers and probes.
Oligonucleotide PCR primer and hybridization probe sets were designed to detect reoviruses, HAV, rotaviruses, and Norwalk virus with the DNASTAR and OLIGO 4.0 software packages. The primers and probes of each set were designed on the basis of conserved regions of viral genomes so that all of the human (but not animal) strains present in the available GenBank and EMBL databases could be detected. As much as possible, primer sets were designed to give similar melting temperature characteristics. The enterovirus set has been previously described (9). Table 1 lists the sequences of the primers and probes used in this study.
|
View this table: [in a new window] |
TABLE 1. Oligonucleotide primers and probes used in this study
|
RT-PCR conditions.
RT reactions were performed by adding 2 µl of a virus stock or groundwater sample to a mixture containing 10 mM Tris (pH 8.3), 50 mM KCl, 1.5 (single-virus and mixture A multiplex reactions) or 1.7 (mixture B multiplex reactions) mM MgCl2, 0.67 mM each deoxyribonucleotide triphosphate (dNTP), and 1.67 µM downstream primers in a final reaction volume of 30 µl. The downstream primers were MRD13 (enteroviruses), MRD155 (rotaviruses), and MRD189 (reoviruses) for mixture A and MRD186 (HAV), MRD194 (HAV), and MRD212 (Norwalk virus) for mixture B. Single-virus reaction mixtures contained only the appropriate primer(s) for the virus group. Each reaction tube was overlaid with 50 µl of sterile mineral oil, and viral RNA was released by heating at 99°C for 5 min. After quenching on ice, 30 U of recombinant RNasin (Promega catalog no. N2515) and 50 U of murine leukemia virus reverse transcriptase (Applied Biosystems catalog no. N8080018) were added. cDNA was prepared by incubation at 43°C for 60 min, followed by a 94°C step for 5 min to inactivate the reverse transcriptase.
PCR was performed by adding 70 µl of a mixture containing 10 mM Tris (pH 8.3), 50 mM KCl, 3.0 or 2.75 mM MgCl2, 0.5 µM each upstream primer, and 5 U of Taq polymerase (Applied Biosystems catalog no. N8080153). The upstream primers were MRD14 (enteroviruses), MRD154 (rotaviruses), and MRD188 (reoviruses) for mixture A and MRD185 (HAV), MRD193 (HAV), and MRD211 (Norwalk virus) for mixture B. Single-virus reaction mixtures contained only the appropriate primer(s) for the virus group. Viral cDNA was amplified with 40 cycles each consisting of 60 s at 95°C, followed by 130 s at 59°C. Following the 40 cycles, samples were incubated at 72°C for 15 min and then kept at 4 or -20°C for long-term storage.
Agarose gel electrophoresis.
Four microliters of RT-PCR product was added to 1 µl of 0.04% bromophenol blue-0.04% xylene cyanol-50% glycerol and run on 1.5% agarose (Amresco catalog no. E776) or 3% NuSieve agarose (FMC catalog no. 50082) gels in 40 mM Tris-5 mM sodium acetate-1 mM EDTA, pH 8.0 (TAE buffer), at 100 V for 45 to 80 min. Gels were stained with TAE buffer containing 1 µg of ethidium bromide per µl. Results were recorded with Polaroid film.
Dot blot hybridization conditions.
Five microliters of PCR product was denatured in 0.4 M NaOH-0.01 M EDTA for at least 10 min at room temperature. Ammonium acetate was added to a final concentration of 2 M, and the sample was immediately spotted onto Magnagraph nylon membranes. The membranes were baked at 80°C for 60 min and hybridized with probes labeled on the 3' end with digoxigenin-ddUTP in accordance with the manufacturer's instructions (Roche catalog no. 1175033). Membranes were prehybridized for 1 h and hybridized overnight at 51°C. Nonspecifically bound probes were removed by washing for 2 x 10 min at 51°C. Probes and wash conditions are given in Table 2.
|
View this table: [in a new window] |
TABLE 2. Hybridization conditions used in this study
|
Quality assurance.
A number of precautions were taken during the study to minimize false-positive results. Separate individuals and rooms were used to perform the following major steps: (i) 1MDS filter elution and celite concentration, (ii) inhibitor removal, (iii) PCR, and (iv) gel electrophoresis and hybridization. Ultracentrifuge buckets and surfaces were cleaned after use with a 10% dilution of commercial bleach. To test for false-positive and false-negative results, negative and positive controls were run with each sample set. The negative controls consisted of an RT-PCR negative control (PBS with 0.2% BSA) and a negative process control (distilled H2O) that was processed in the same way as groundwater samples and run with each set of samples processed for inhibitor removal in the laboratory. Positive controls consisted of an RT-PCR positive control (virus-seeded negative process control) and virus-seeded groundwater samples. All PCR results were confirmed by hybridization. Only samples that were positive by hybridization and not presumptively false positive or false negative were counted as positive.
|
|
|---|
Because simpler methods did not show good levels of virus recovery, it was decided to examine ultracentrifugation through a sucrose pad, a common method for initial purification and concentration of picornaviruses (25). The conditions of ultracentrifugation were designed so that viruses pelleted through the sucrose while less dense ribosomes did not. Thus, it was theorized that the sucrose pad could remove a number of inhibitors. Initial experiments indicated that greater than 80% of poliovirus could be recovered by this method and that it removed the inhibitors present in groundwater from an initial test site. However, as other sites were tested, it was found that ultracentrifugation alone was not adequate.
A series of chemical and solvent mixtures were tested for the ability to remove inhibitors. These experiments led to the use of a mixture of 0.01% dithiozone and 0.01 M 8-hydroxyquinoline in chloroform-butanol-methanol-trichloroethane (0.1/0.9/1/0.25/0.25, vol/vol). Figure 1 shows the results obtained with this mixture when it was tested on seven groundwater samples. The positive results seen in lanes 10 to 15 suggest that inhibitors were effectively removed.
![]() View larger version (100K): [in a new window] |
FIG. 1. Inhibitor removal from groundwater samples. Single-enterovirus primer RT-PCRs were performed on seven solvent-treated groundwater samples. Unseeded samples (lanes 3 to 8) or samples seeded with 500 particles of poliovirus (lanes 10 to 15) were analyzed. PBS and virus-seeded PBS were run as a negative (lane 2) and positive controls (lane 9). Products were analyzed on a 1.5% agarose gel. Lane 1 contains a 123-bp ladder. The arrow indicates the location of the 196-bp poliovirus RT-PCR fragment.
|
|
View this table: [in a new window] |
TABLE 3. Overall virus recovery during inhibitor removal
|
Multiplex RT-PCR.
PCR primer and hybridization probe sets were designed or chosen to detect enteroviruses, HAV, Norwalk virus, reoviruses, and rotaviruses in environmental samples. Each set was designed to produce a unique PCR fragment size that could be detected by agarose gel electrophoresis (Fig. 2). The PCR products were 126 bp (lanes 3 and 4) for reovirus, 196 bp for enteroviruses (lanes 3 and 4), 380 bp for rotaviruses (lanes 3 and 4), 222 and 396 bp for HAV (lanes 6 and 7), and 361 bp for Norwalk virus (lanes 6 and 7). In addition to specific bands, a minor rotavirus-related band of about 305 bp (lanes 3 and 4) was often observed.
![]() View larger version (51K): [in a new window] |
FIG. 2. Multiplex RT-PCR. Standard multiplex RT-PCR mixture A (lanes 2 to 4) and B (lanes 5 to 7) reactions were performed and analyzed on a 3% NuSieve agarose gel. Mixture A viruses (poliovirus, reovirus, and rotavirus) were added to the reaction mixture shown in lane 3. A 10-fold dilution of mixture A was added to the reaction mixture shown in lane 4. Mixture B viruses (HAV and Norwalk virus) were added to the reaction mixture shown in lane 6 (RT-PCR mixture B contains two primer sets for HAV, generating two unique PCR fragments). A 10-fold dilution of mixture B was added to the reaction mixture shown in lane 7. Lanes 2 and 5 contained mixture A and B negative control samples, respectively. Lane 1 contains a 123-bp ladder.
|
Although PCR primer sets were designed to generate unique fragment sizes, extraneous bands were always present in groundwater samples (Fig. 1). Thus, gel electrophoresis was a useful tool for optimization studies but could not be used to determine whether viruses were present in groundwater samples. Specific hybridization probes were designed for each primer set, and conditions were optimized so that all hybridization reactions could be performed at the same temperature (data not shown).
Groundwater analyses.
A total of 321 monthly samples from 29 groundwater sites were analyzed by the multiplex RT-PCR method (Table 4). A total of 16% of the samples and 72% of the sites were found to be positive for human enteric viruses. Enteroviruses were present in 5% of the samples, reoviruses were present in 10%, HAV was present in 1%, and Norwalk virus was present in 3% of the samples. Rotaviruses were not detected.
|
View this table: [in a new window] |
TABLE 4. Virus analyses of groundwater samples
|
The percentage of samples that were positive for viruses was the same for both the initial and final conditions. However, the initial samples tended to have larger sample volumes, which may have compensated for the lower recovery (Table 3). The average equivalent amounts of groundwater tested in each RT-PCR assay were 100 liters for the initial samples and 59 liters for the final conditions, with an overall average of 71 liters.
Eleven samples, including 6 of the 20 that were positive by a cell culture assay (see reference 19), were not assayed by the multiplex RT-PCR method. Surprisingly, only 1 of the 14 cell culture-positive samples was positive for a culturable virus type by multiplex RT-PCR. The 14 samples were retested with 10 µl of concentrated sample per assay and a single-virus RT-PCR assay. On retest, 10 samples (71%) were positive, 3 were negative, and 1 gave a potentially false-positive result.
|
|
|---|
It was decided that a primary initial criterion for choosing a method for inhibitor removal was to identify one that would give at least 50% virus recovery. Simple spin chromatography and PEG concentration methods did not meet this criterion. An ultracentrifugation step was used for initial removal of inhibitors from celite concentrates. It was necessary to precoat the ultracentrifuge tubes with BSA to obtain reproducible virus recoveries (Table 3). When it was found that ultracentrifugation alone was not adequate for removal of all inhibitors, several solvents were tested for removal efficacy. Solvents were initially selected on the basis of the ability to remove UV and visible light-absorbing material from shellfish tissue over a range of 200 to 640 nm (G. S. Fout and B. C. Martinson, unpublished data). The final solvent combination was derived from those that (i) provided the greatest reduction in absorbing material, (ii) gave a virus recovery following extraction of 14C-labeled poliovirus in celite extract of greater than 85%, and (iii) reduced inhibition. Dithiozone and 8-hydroxyquinoline were added to the solvent mixture because they are chelators of heavy metal ions, which are known to cause inhibition (16, 27). The Microcon-100 concentration step was added to remove residual solvents and other inhibitors of less than 100,000 Da and to provide a greater degree of sample concentration. The overall procedure resulted in effective reduction of inhibitors from groundwater samples (Fig. 1 and Table 4) and an average virus recovery of 74% ± 7% (Table 3).
Groundwater samples were assayed by multiplex RT-PCR for enteroviruses and reoviruses because these are the virus groups that are usually detected by culture assays (12). Rotaviruses were included because they are the leading cause of gastroenteritis in children in the United States and because they caused a waterborne disease outbreak in the United States in 1981 (14). HAV and Norwalk virus were included because they are known to have caused a number of waterborne disease outbreaks (e.g., see reference 4).
Reasons for developing a multiplex RT-PCR procedure were to minimize the number of reactions needed and reduce the cost of water sample screening for enteric viruses. Because an ultracentrifuge rotor holds only six samples, five groundwater samples and a negative process control were processed for inhibitor removal and analyzed by multiplex RT-PCR as sets. The use of the multiplex procedure reduced the number of RT-PCR assays from 70 to 26 per set. With an average reagent cost of about $4.50 per RT-PCR assay, the cost for groundwater sample analysis by the multiplex RT-PCR procedure was about $24.00 per sample, exclusive of labor and equipment costs. It would be desirable to develop a single multiplex reaction with internal controls (26), which could reduce the reagent cost to about $7.00 per water sample.
Overall, 16% of 321 monthly samples and 72% of 29 groundwater sites in the continental United States, the Virgin Islands, and Puerto Rico were positive for human enteric viruses by the multiplex RT-PCR method (Table 4). However, 62% of the samples that were positive for virus by RT-PCR were from seven groundwater sites (24% of the sites). Microscopic particulate analysis was used to rate the risk that these sites are under the influence of surface water (19). Three of the seven sites that showed the most positive samples were rated as being at moderate risk, and four were rated as being at low risk. The three sites that were at moderate risk were in karst formations. The other four sites were in sedimentary, alluvial, or glacial deposits. Reovirus was the most frequently detected virus, with 10% of the samples and 62% of the sites tested being positive. Of the viruses most often associated with waterborne outbreaks, HAV was detected in 1% of the samples and 14% of the sites while Norwalk virus was detected in 3% of the samples and 21% of the sites.
A total of 6% of the samples and 24% of the sites were positive by a culture assay (7, 19). Despite good recoveries with the inhibitor removal procedure (Table 3), there was no good statistical correlation between the culture and molecular assays (data not shown). A main cause for the lack of agreement between the assays was a large difference in assay volumes. The average amount of sample concentrate used in this study for culture and molecular assays was equivalent to 2,181 and 71 liters of groundwater, respectively. When samples that were positive by cell culture were retested with a single primer set assay and a 10-µl assay volume, the two methods were in agreement for 7 of 10 samples tested. The remaining lack of correlation may have resulted from the detection of noninfectious virus or nonculturable coxsackie A viruses.
Because of its importance to public health decisions, the relevance of positive molecular results to public health risk needs to be adequately addressed. It is likely that in certain environmental water types there will be a relevance, but even if there is none, multiplex assays may prove to be useful for rapid screening of water for evidence of virus occurrence. Positive results would then have to be followed up with other tests, such as the integrated cell culture-PCR assay (23), to determine the significance of the findings.
The use of a process negative control in addition to a PCR negative control was important for the identification of presumptively false-positive results, which occurred with 6% of the samples. The level of false-positive results was surprising because of the extent to which all portions of the work were separated. However, most of these false results were associated with the reovirus primer set. This set generated the smallest PCR fragment and appeared to have the highest efficiency of amplification.
False-negative results occurred with 14% of the samples. The inhibitor removal process did not completely remove inhibition from 1 of the 29 groundwater sites, where 47% of the samples gave potentially false-negative values. Most of the other false-negative results were associated with the enterovirus and Norwalk virus primer sets and may have been associated with their poorer efficiency of amplification (Fig. 2). Very low seed levels were used for this study, and this may also have contributed to some of the false-negative results. It is recommended that the seed levels be increased to 100 to 200 RT-PCR units for future studies and that working stocks be carefully aliquoted so that they are frozen and thawed only once.
The U.S. EPA has proposed a Groundwater Rule (www.epa.gov/safewater/gwr.html) that will require public groundwater sites considered to be vulnerable to fecal pollution following sanitary surveys to be monitored monthly for fecal indicators. Sites at which indicators are found must be treated with corrective action that can range from removal of pollution sources to disinfection. The sites assayed for viruses in this study were chosen because they were considered vulnerable and because their water was already being disinfected. Therefore, the positive virus findings of this study do not constitute a public health risk. However, the lack of correlation of virus findings to traditional indicators (19) at highly vulnerable sites puts into question whether indicators will adequately predict public health risk at less vulnerable sites.
We appreciate the project coordination of Richard J. Lieberman, the EPA Project Manager, and Martin J. Allen, the AWWARF Project Manager. We also acknowledge the technical assistance of Shari R. Crout, Daniel J. Williams, Gretchen T. Sullivan, and Ishrat Abubaker.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»