Previous Article | Next Article ![]()
Applied and Environmental Microbiology, March 2004, p. 1366-1377, Vol. 70, No. 3
0099-2240/04/$08.00+0 DOI: 10.1128/AEM.70.3.1366-1377.2004
Copyright © 2004, American Society for Microbiology. All Rights Reserved.
Institute of Food and Agricultural Technology, University of Girona, Girona,1 Institute of Molecular Biology-Consejo Superior de Investigaciones Científicas, Barcelona, Spain,2 Veterinary Molecular Microbiology Section, University of Bristol, Langford BS40 5DU, United Kingdom3
Received 21 August 2003/ Accepted 21 November 2003
|
|
|---|
|
|
|---|
As well as not always being reliable, conventional bacteriological methods for the detection and quantification of L. monocytogenes are laborious and time-consuming and require individual biochemical confirmation of the species in a number of isolated colonies (7). These drawbacks are overcome by PCR-based methods, particularly by the development of real-time PCR (RTi-PCR), which is highly specific and can very accurately quantify target DNA (which is directly related to the size of the bacterial population present in the sample). As this quantification is based on the emission of a fluorescence signal as the specific PCR progresses, no post-PCR manipulations are required. This feature reduces the risk of cross-contamination in the laboratory and permits high throughput and automation (reviewed in reference 22).
A potential problem that can seriously compromise the applicability of the RTi-PCR technique for quantification purposes is the existence of interstrain variability in the target DNA sequence. Although sequences exhibiting a certain degree of divergence can still be detected, primers and probes anneal less efficiently to nonidentical target sequences, resulting in weak signals and underestimation of the amount of DNA in the sample. Most PCR assays for L. monocytogenes are based on the detection of the virulence genes hly and iap, encoding the hemolysin listeriolysin O (27) and the invasion-associated surface protein p60 (23), respectively. A number of RTi-PCR assays based on these targets have been developed (12, 18, 24, 29), but the quantification abilities of these assays were assessed with only one L. monocytogenes isolate. While the hly gene is relatively well conserved in all L. monocytogenes strains, the iap gene is not. Although iap contains conserved portions at the 5' and 3' ends, its central region is highly variable and contains sequence polymorphisms even among strains of the same serovar (5, 26, 33).
Here we evaluated the usefulness of the hly and iap genes as targets for the specific quantitative detection of L. monocytogenes by RTi-PCR. Specific, sensitive, and accurate quantification of L. monocytogenes was consistently achieved with the hly-based assay. The iap-based assay, in contrast, yielded heterogeneous results, and reliable quantification was possible only when homologous strains or strains belonging to the same serovar-related phylogenetic branch were tested. We also developed an efficient quantitative PCR assay for L. innocua based on the detection of lin02483 gene sequences. Finally, we assessed the new AmpliFluor system (Intergen Co., Purchase, N.Y.) for the detection of food-borne pathogenic bacteria. In contrast to the widely used TaqMan system, which requires an energy tranfer-labeled probe specific for each PCR assay, the AmpliFluor technology uses a universal energy transfer hairpin primer (UniPrimer) which emits a fluorescence signal when unfolded during its incorporation into an amplification product. The UniPrimer contains a 3' Z tail sequence that is also present at the 5' end of one of the target-specific primers so that it anneals to the PCR product and acts as a universal PCR primer. In our experiments, the AmpliFluor and TaqMan technologies performed similarly, with only slight differences in detection and quantification limits.
|
|
|---|
|
View this table: [in a new window] |
TABLE 1. Listeria strains used in this studya
|
|
View this table: [in a new window] |
TABLE 2. Non-Listeria strains used in this studya
|
Oligonucleotides.
Primer Express, version 2.0, software (Applied Biosystems Division, Perkin-Elmer Corp., Foster City, Calif.) was used to design oligonucleotides targeting the L. monocytogenes hly gene (GenBank accession no. M24199) (27) and iap gene (GenBank accession no. X52268) (23) and the L. innocua lin02483 gene (http://genolist.pasteur.fr/ListiList/). The oligonucleotides were purchased from MWG-Biotech AG (Ebensburg, Germany).
PCR.
TaqMan RTi-PCR assays were performed and evaluated essentially as described by Hernández et al. (13) with TaqMan PCR core reagents (Applied Biosystems-Roche Molecular Systems Inc., Branchburg, N.J.) and a 20-µl reaction volume containing 1x PCR TaqMan buffer A (including 5-carboxy-X-rhodamine [ROX] as a passive reference dye); 4.5 mM (iap reactions) or 6 mM (hly and lin02483 reactions) MgCl2; 200 µM each dATP, dCTP, and dGTP; 400 µM dUTP; 50 nM primers; 100 nM probe; 1 U of AmpliTaq Gold DNA polymerase; 0.2 U of AmpErase uracil N-glycosylase; and 1 µl of the target DNA solution. Reactions were run on an ABI Prism 7700 apparatus (Applied Biosystems Division, Perkin-Elmer) with the following program: 2 min at 50°C, 10 min at 95°C, and 50 cycles of 15 s at 95°C and 1 min at 63°C. AmpliFluor RTi-PCR assays were performed with a 20-µl reaction volume containing 1x Ex Taq buffer (TaKaRa Bio, Inc., Shiga, Japan), 1.5 mM MgCl2, 250 µM each deoxynucleoside triphosphate, 50 nM hlyZ primer, 500 nM hlyQR primer, 500 nM UniPrimer (Intergen Co., Purchase, N.Y.), 1 U of TaKaRa Ex Taq polymerase, and 1 µl of the target DNA solution. The conditions for AmpliFluor RTi-PCR assays were 4 min at 95°C and 45 cycles of 15 s at 95°C, 20 s at 55°C, and 40 s at 72°C. Fluorescence was measured only at the melting point.
TaqMan and AmpliFluor RTi-PCR assays were evaluated by using sequence detection system software, version 1.7 (Applied Biosystems Division, Perkin-Elmer). Quantification was performed by interpolation in a standard regression curve of threshold cycle (CT) values generated from samples at known concentrations. Negative values or a lack of amplification for RTi-PCR was set at a CT value of >50 or >45 for the TaqMan or the AmpliFluor system, respectively. Unless otherwise stated, all reactions were performed in triplicate. The 95% confidence interval was calculated for every serial dilution. The calculations were performed according to a binomial distribution (21) by using the SAS statistical software system for Windows, version 8.0 (SAS Institute Inc., Cary, N.C.).
Conventional PCR assays were performed under the same conditions as those used for TaqMan RTi-PCR assays, except that PCR buffer II was used instead of PCR TaqMan buffer A. PCR products were detected by ethidium bromide staining after electrophoresis in 3% agarose gels.
Sequencing of hly and iap gene fragments.
L. monocytogenes genomic DNA was PCR amplified with primers hlyF and hlyR (512-bp fragment) and primers iapF and iapR (687-bp fragment) (Table 3) in 50-µl reaction mixtures containing 1x PCR buffer II, 1.5 mM MgCl2, 200 µM each deoxynucleoside triphosphate, 0.9 µM primers, and 1 U of AmpliTaq Gold DNA polymerase. Reactions were performed by using GeneAmp PCR system 9600 (Applied Biosystems Division, Perkin-Elmer) and the following program: 10 min at 95°C; 40 cycles of 20 s at 95°C, 30 s at 56°C (hly) or 53°C (iap), and 1 min at 72°C; and a final extension of 7 min at 72°C. The PCR products were purified by using a QIAEXII gel extraction kit (Qiagen, Hilden, Germany) and sequenced on both strands with the same primers by using an ABI Prism Big Dye Terminator, version 3.0, cycle sequencing kit and an ABI Prism 377 DNA sequencer (Applied Biosystems Division, Perkin-Elmer).
|
View this table: [in a new window] |
TABLE 3. Oligonucleotides used in RTi-PCR assays for L. monocytogenes and L. innocua and target gene sequencing
|
|
|
|---|
Primer, TaqMan probe, and MgCl2 concentrations were optimized for TaqMan RTi-PCR assays by using as a template 1 ng of DNA from L. monocytogenes strain UdG 1010 or L. innocua strain CECT 910. Optimal conditions (described in Materials and Methods) were the minimum primer and probe concentrations giving the lowest CT value and the highest fluorescence intensity for a normalized reporter value (Perkin-Elmer Applied Biosystems User Bulletin 2 [ABI Prism 7700 sequence detection system], 1997). These conditions yielded the largest quantity of amplification product from the corresponding target DNA in conventional PCR assays.
Specificity of the assays.
The capacity of our PCR assays to discriminate between target and nontarget bacteria was tested by using as a template 1 ng of genomic DNA (
3 x 105 CFU) from 100 Listeria strains and 45 non-Listeria strains. Only the target species were detected by both RTi-PCR and conventional PCR (Tables 1 and 2). Tests were also performed with a representative set of strains (13 L. monocytogenes, 4 L. innocua, 21 other Listeria, and 33 non-Listeria strains) by using as a template either 1 µl of an overnight liquid culture or a colony from an agar plate. The results were the same as those obtained with purified genomic DNA. These data indicated that the PCR assays were specific for L. monocytogenes and L. innocua.
Sensitivity and quantification range of the assays.
The detection and quantification limits of the PCR assays were determined by using genomic DNA isolated from overnight cultures of L. monocytogenes strain UdG 1010 and L. innocua strain CECT 910. Amplification reactions were performed with a range of DNA concentrations equivalent to approximately 3 x 105, 3 x 104, 3 x 103, 3 x 102, 60, 30, 15, 8, 4, and 1 target molecules. On the basis of the sizes of the L. monocytogenes and L. innocua genomes (10), one molecule of genomic DNA corresponds to 2.94 and 3.01 fg of DNA, respectively. Figure 1 illustrates the amplification profiles and the regression curves obtained with each RTi-PCR assay; Table 4 shows the mean CT values for a total of nine replicates in three independent experiments. The RTi-PCR assays yielded similar results in terms of absolute detection values. Positive amplification in all nine replicates of each DNA dilution was achieved when 8 or more target molecules were present (15 for lin02483), and as few as 1 target molecule could be detected with 33 to 55% probability (11% for lin02483) (Table 4). Conventional reactions consistently detected the target molecules when at least 60 target molecules were present and could detect 15 target molecules with a 44% probability.
![]() View larger version (39K): [in a new window] |
FIG. 1. RTi-PCR detection and amplification of the hly, iap, and lin02483 sequences. Representative amplification plots are shown. Serial dilutions of L. monocytogenes or L. innocua genomic DNA, equivalent to 3 x 105 ( ), 3 x 104 ( ), 3 x 103 (), 3 x 102 ( ), 60 ( ), 30 ( ), 15 ( ), and 8 ( ) target molecules per reaction, were used. Note that the AmpliFluor reactions could not detect 15 and 8 target molecules. Insets show representative standard curves generated from the amplification data. Rn, normalized reporter value (with ROX). R, reporter value (without ROX).
|
|
View this table: [in a new window] |
TABLE 4. Detection and quantification limits of RTi-PCR assays with genomic DNA from standard curve strains L. monocytogenes UdG 1010 and L. innocua CECT 910
|
The sensitivity of the RTi-PCR assays was investigated by using intact bacterial cells instead of DNA. Tenfold dilutions of overnight cultures of L. monocytogenes UdG 1010 and L. innocua CECT 910 were used as templates in the RTi-PCR assays and were plated in parallel to count the bacterial CFU. The overall detection limit for the RTi-PCR assays was 30 CFU, although just 3 CFU were detected in 55.55% (lin02483), 66.66% (iap), and 88.89% (hly) of the replicates (Table 5). Linear regression analysis of CT values and bacterial numbers in the reactions yielded R2 values (above 0.996) and slopes (Table 5) similar to those obtained with purified genomic DNA, indicating that our RTi-PCR assays potentially can be used to quantify accurately the L. monocytogenes or L. innocua populations present in a sample.
|
View this table: [in a new window] |
TABLE 5. Detection and quantification limits of RTi-PCR assays with suspensions of standard curve strains L. monocytogenes UdG 1010 and L. innocua strain CECT 910a
|
|
View this table: [in a new window] |
TABLE 6. Quantification accuracy of RTi-PCR assays for L. monocytogenes and L. innocuaa
|
Impact of target gene sequence polymorphisms on the quantitative performance of the L. monocytogenes-specific RTi-PCR.
The above results prompted us to investigate in more detail the effect of interstrain hly and iap target sequence polymorphisms on our RTi-PCR assays. The hly- and iap-based RTi-PCR assays were carried out by using 1 ng of purified DNA from 40 strains representing most of the known L. monocytogenes serovars (Table 1), and the mean CT values were calculated from four independent experiments. For hly-targeted reactions, the mean CT values were all within a range of 1 cycle and had an overall standard deviation of 0.46. Conversely, the CT values obtained with the iap-based RTi-PCR assay had strong deviations, up to 7.8 cycles, depending on the L. monocytogenes strain tested. Interestingly, the CT values were distributed into two categories that coincided with the serotype-related phylogenetic divisions of L. monocytogenes (see above). Thus, strains of division II serovars had CT values (mean and standard deviation) of 19.24 ± 0.79, whereas strains of division I or III serovars had significantly higher (P < 0.05) CT values (23.80 ± 1.30). The results of these analyses are represented in Fig. 2A, in which the iap CT values were normalized to those of the hly reaction (i.e., iap CT - hly CT) as a reference to control for possible variability due to differences in DNA quantity or quality. According to our data, L. monocytogenes strains belonging to division II have an iap/hly CT value of <3 (mean value, 1.09), and those belonging to divisions I and III have an iap/hly CT value of >3 (mean value, 5.56) (Fig. 2A). Interestingly, our assay identified serovars 4d and 7 as belonging to division I or III.
![]() View larger version (59K): [in a new window] |
FIG. 2. Effect of target gene sequence polymorphisms on the performance of the iap RTi-PCR assay. (A) Normalized CT values (iap/hly; see the text) obtained with 40 L. monocytogenes strains of different serovars (indicated below the graphs). The results for each strain (mean of four replicates) are represented by bars. Note that the strains can be ascribed to two statistically significant groups (P < 0.05) which coincide with serovar-related phylogenetic division I or III (serovars 1/2b, 3b, 4a, 4b, 4c, 4d, and 7) and division II (serovars 1/2a, 1/2c, 3a, and 3c) of L. monocytogenes delimited by an iap/hly CT value of 3. Note also that two strains of serovar 1/2a have higher iap/hly CT values (indicated by an asterisk); these strains harbor a mismatch in the target sequence of the probe (see panel B, sequence 2, black shading). (B) Nucleotide sequences of hly and iap fragments targeted by PCR primers and probes (boxed, with arrows indicating the 5' 3' orientation) (Table 3). The bottom panel shows strains CECT 911, CECT 938, UdG 1010, and UdG 1011 (sequence 1); strains CECT 932 and CECT 4031 (sequence 2); strains CECT 935, CECT 936, CECT 937, CECT 940, CECT 4032, and UdG 1034 (sequence 3); and strain CECT 934 (sequence 4) (Table 1). Mismatches are represented by black shading.
|
Assessment of AmpliFluor technology.
We also carried out a series of experiments to assess the performance of AmpliFluor technology for the quantitative detection of L. monocytogenes by RTi-PCR. We used the same hlyQF and hlyQR primers, the former including a Z tail sequence (hlyZ), and the optimal conditions described in Materials and Methods. For the same samples, AmpliFluor assays were as specific as TaqMan assays, although the detection limit of the former was slightly higher (Table 4), equivalent to that of conventional PCR assays. The AmpliFluor reactions were efficient and showed a linear and accurate relationship between the CT value and the initial DNA concentration over a 5-log range (slope of the linear regression curve, -4.67; R2, 0.999). Quantification was reliable when 60 or more target molecules were present. The AmpliFluor assays also performed adequately when L. monocytogenes cells were used as a template (Table 5), allowing reliable quantification of 300 target CFU and detection of 30 CFU in 22% of the replicates.
|
|
|---|
Perhaps one of the most challenging aspects of designing methods for the detection of food-borne pathogens is achievement of a low detection limit. This goal is of particular interest for L. monocytogenes, as it is often present in low numbers in food products (7, 8). The RTi-PCR assays that we developed could detect approximately one target genome in at least 11% of the experiments, 3 CFU in 55 to 89% of replicates, and 30 CFU in all cases. Detection limits were similar to those previously reported for other RTi-PCR assays targeting single-copy genes (14, 15, 16, 29). Limits of detection of 9 (18), 6 to 60 (29), and 500 (24) target molecules were previously reported for hly, and six genome copies were reported for iap (12).
The quantification accuracy of our assays was excellent compared to that of the reference microbiological method (relative quantification accuracy) (2) under optimal conditions; i.e., the RTi-PCR results were very similar to the quantitative results obtained by the plate count method over a wide range of CFU for the standard curve strains. However, the performance of RTi-PCR and, thus, its detection limit and quantification accuracy, depend on the degree of conservation of the target sequence(s) of the particular microorganism being analyzed. Strains of L. monocytogenes have been divided into three serovar-related homology groups or divisions on the basis of gene sequence diversity (19, 26, 28, 33, 42-44). To ensure that our hly- and iap-based RTi-PCR assays were appropriate for the precise quantification of an L. monocytogenes strain regardless of its genetic background, we extensively evaluated our oligonucleotides by using a large panel of isolates of serovars representative of the three phylogenetic divisions of the species. The hly-based RTi-PCR assay always yielded perfectly homogeneous results with all of the strains tested and had excellent quantification accuracy for bacteria from serovars belonging to different homology groups (i.e., divisions I, II, and III), indicating that this assay can be applied to the entire species L. monocytogenes. Preliminary results obtained with different L. innocua strains indicated that the species-specific lin02483 RTi-PCR assay behaves similarly.
The situation was completely different with the iap-based RTi-PCR assay. Although this assay targets the 5' conserved portion of the iap gene, our results demonstrated that it was reliable only for L. monocytogenes strains from the same homology group as the strain used to design the primers and probe (division II). Although strains from different homology groups (divisions I and III) yielded positive amplification signals, the efficiencies of the reactions were too low, and quantification was not possible. These results indicate that the iap-based assay cannot be routinely used for the quantitative detection of L. monocytogenes under field conditions. These results also highlight the need to assess primers and probes for quantification purposes carefully and exhaustively, by using a large and comprehensive collection of isolates representative of the biodiversity within the target species, before an RTi-PCR assay is adopted for routine quantitative testing. Finally, they show that target sequences prone to genetic variability must be avoided even when a conserved region is selected. This issue is not trivial, because a number of RTi-PCR assays targeting iap were recently described for the quantitative detection of L. monocytogenes (12, 24). The frequency of spontaneous mutations in prokaryotes, aggravated by the relative abundance of hypermutation phenotypes among certain pathogenic bacteria (3, 30), therefore appears to be a potential limitation of RTi-PCR-based methods for the quantitative detection of bacterial pathogens in natural samples.
Analysis of the target sequences in a sample of isolates representative of the three homology divisions of L. monocytogenes showed that the number of mismatches in the primer and probe sequences is directly correlated with the efficiency of the RTi-PCR. Strains with target sequences containing three or four mismatches in the iap-specific primers and probe (division I or III serovars) were inefficiently amplified and had CT values about 7 cycles higher than those obtained in the hly-based RTi-PCR (Fig. 2). In contrast, strains with target sequences identical to the iap-specific primers and probe (division II serovars) were very efficiently amplified and had CT values close to those obtained in the hly-based assay. It must be noted that two strains of serovar 1/2a (division II) exhibited a single mismatch in the probe sequence which slightly increased the CT value (Fig. 2). The observed correlation allowed us to establish a cutoff for iap-based RTi-PCR CT values (3 cycles after normalization to hly-based CT values) that divided the L. monocytogenes strains into two statistically different groups corresponding to division II and to division I or III (Fig. 2A). An example is strain PAM 602; this strain was originally classified as L. seeligeri but, according to its CT value, corresponded to a division I L. monocytogenes strain. Reidentification and serotype determination confirmed that PAM 602 was indeed L. monocytogenes serovar 1/2a (Table 1), suggesting that the iap-based RTi-PCR assay could be used in conjunction with the "universal" hly-based assay for rapid discrimination between division II and division I or III L. monocytogenes strains. This application is interesting because most clinical isolates of L. monocytogenes belong to division I (primarily serovar 4b, followed by serovar 1/2b), whereas division II isolates are less frequently associated with disease (in particular, serovar 1/2c, which is frequently found in food but rarely found in listeriosis patients) (4, 28, 33, 38, 42, 44, 45). Within division II, the iap-based assay discriminated strains of serovar 1/2a harboring point mutations in the probe sequence (serovar 1/2a has been shown to split into two sequence homology groups) (39) (Fig. 2A).
Finally, we also assessed AmpliFluor technology for the quantification of L. monocytogenes by using primers targeting the hly gene. We compared the efficiency of this technique with that of the TaqMan system. The AmpliFluor assay was, like the conventional PCR assay, slightly less sensitive, as the detection limit was 15 target molecules. The quantification limit was also slightly less favorable with the AmpliFluor assay (60 target molecules versus 15 with the TaqMan assay). Otherwise, the accuracies were high with both techniques (R2 values of >0.996), and the linearity persisted up to 3 x 106 molecules (data not shown). Although in our experiments the AmpliFluor technique was slightly less efficient than the TaqMan technique, it offers the theoretical advantage of being less sensitive to mutations in the target DNA because it does not require a third (probe) target sequence. It is also more cost-effective when different genes are to be targeted because of the use of the universal fluorigenic UniPrimer and is easy to adapt on the basis of previously established conventional PCR systems. This is the first time that a universal RTi-PCR probe (UniPrimer, based on a Z tail sequence, which is claimed to be nonexistent in nature) has been used for the specific detection and quantification of a food-borne pathogen. We show experimentally that it does not cross-react with a number of bacterial species (Tables 1 and 2).
In conclusion, we report highly specific, sensitive, and reliable RTi-PCR assays for the quantitative detection of L. monocytogenes and L. innocua. The assays show excellent quantification characteristics in terms of both linear dynamic range and relative accuracy with respect to the standard plate count technique, thus offering a promising alternative to traditional microbiological methods. We also warn about the dangers of using genes prone to genetic variability as targets for RTi-PCR-based detection of food-borne pathogens and emphasize the necessity of extensively checking assays with the broadest possible panel of representative strains, as interstrain sequence polymorphisms affecting target sequences can result in an underestimation of the bacterial load present in a sample by several orders of magnitude.
We thank M. Hugas and N. Cook for providing bacterial strains; H. Monzó for help with DNA extractions; and C. Jacquet, J. Rocourt, and P. Martin (Listeria Reference Laboratory, Institut Pasteur, Paris, France) for serotyping PAM isolates.
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»