Assessment of the Ability of the Bioelectric Effect To Eliminate Mixed-Species Biofilms
Mark E. Shirtliff,1*
Alex Bargmeyer,2 and
Anne K. Camper2
Department of Biomedical Sciences, Dental School, University of MarylandBaltimore, 666 W. Baltimore Street, Baltimore, Maryland 21201,1
Center for Biofilm Engineering, 366 EPS Building, Montana State University, Bozeman, Montana 59717-39802
Received 18 February 2005/
Accepted 17 May 2005

ABSTRACT
Microbes have been able to persist in water distribution systems
through the development of multicellular communities known as
biofilms. This study evaluated the usefulness of the bioelectric
effect for the elimination of water distribution system biofilms
from annular reactors. The bioelectric effect did not have any
bactericidal action either alone or when coupled with free chlorine.

INTRODUCTION
The utilization of adequate water management methods has vastly
contributed to lowering human mortality and improving quality
of life (
4-
6,
9). However, a number of microbes have been able
to persist in water distribution systems by the development
of a multicellular community known as a biofilm (
3). A strategy
to effectively eliminate biofilms from water distribution systems
may be through the application of the bioelectric effect. This
effect was initially noted by Costerton et al. and Jass et al.
(
2,
7), who showed that the efficacy of antibiotics was increased
through the application of weak electric fields. While the cause
of the bioelectric effect remains unexplained, a number of other
researchers have also noted the bioelectric effect (
8,
10-
12).
This study was designed to evaluate the ability of the bioelectric
effect to enhance the antimicrobial properties of free chlorine
against mixed-population biofilms of drinking water origin.
Biofilms were grown in annular reactors (BioSurface Technologies Corp., Bozeman, MT) that consisted of a stationary outer cylinder with 20 flush-mounted, polycarbonate, removable slides for biofilm sampling on an inner drum. The inner drum rotates, providing a shear stress at the reactor wall that simulated 1 ft/s. The inner drum also contains draft tubes to ensure vertical as well as horizontal mixing. For a carbon source, humic concentrate prepared as described previously (1) was added to the reactors to produce a final concentration of 1.5 ppm carbon in the reactors.
Stainless-steel electrodes (positive and negative) were placed against the walls of the reactor at opposite sides of the inner rotating drum and connected to a power supply that provided a constant flux of 3.7 µA/mm2 through the reactor, as determined by a multitest ammeter. This current flux was previously shown to be effective in producing a significant bioelectric effect (2, 7, 8). In preliminary studies, metal flocs were generated by the exposure of iron-based reactor components to the direct current. Therefore, internal iron surfaces of the reactors were insulated from the electrodes and system water by application of a silicon sealer.
Humic concentrate was prepared by mixing Elliot silt loam soil (120 g) in 0.1 M sterile NaOH (1 liter) for 48 h at room temperature. The mixture was centrifuged (20 min, 10,000 x g), and the supernatant was recovered. The total carbon concentration was determined for the supernatant and diluted to a final concentration of 12.5 ppm. Sterile potassium nitrate and dibasic potassium phosphate were added to the supernatant to provide final concentrations of 1.25 ppm and 0.125 ppm, respectively, and the pH was adjusted to 7.20. This supplemented and pH-adjusted humic concentrate was combined with tap water treated in laboratory-scale granular activated carbon filters filled with filter medium from a biological treatment facility in Laval, Quebec, Canada, at 1 ml/min and 7.33 ml/min, respectively. The end result was a mixture consisting of 1.5 ppm carbon, 0.15 ppm nitrate, and 0.015 ppm phosphate and a residence time of 120 minutes. These reactor conditions represented a scenario in which negligible reactive chlorine and elevated carbon levels existed for an extended period of time in a water delivery system. We were able to define when biofilm growth had attained steady state by taking repeated samples over subsequent days.
While previous experiments evaluating the bioelectric effect have utilized chloride-free media (see above), our system had measurable levels of chloride ions like those of standard water delivery systems. Therefore, the passage of current through a solution containing these ions may have created reactive chlorine-based substances, such as free chlorine (e.g., Cl2, OCl, and HOCl), chlorine dioxide (ClO2), chlorite (ClO2), monochloramine (NH2Cl), dichloramine (NHCl2), and trichloramine (NCl3), due to electrolysis.
We then evaluated the ability of the bioelectric effect to enhance the antimicrobial properties of free chlorine against mixed-population biofilms of drinking water origin. Biofilms were grown until they had attained steady state and then were evaluated with a number of control and experimental groups (Table 1). The free-chlorine infeed was derived from household bleach (5.25% [wt/vol] sodium hypochlorite), and infeed concentrations were confirmed by using a standard n,n-diethyl-p-phenyldiamine (DPD) colorimetric method (Hach Inc., Loveland, CO). The two infeed free-chlorine concentrations, 0.5 mg/liter and 5.0 mg/liter, provided residual-chlorine concentrations of approximately 0.06 mg/liter and 1.5 mg/liter, respectively, within the annular reactors.
View this table:
[in this window]
[in a new window]
|
TABLE 1. Control and experimental annular reactor groups for the evaluation of the bioelectric effect (with and without free-chlorine addition) to eliminate mixed-species water biofilms
|
Biofilm and planktonic samples were obtained at 0, 6, 12, 24,
48, and 168 hours after initiation of the experiment. These
samples were homogenized, serially diluted, and plated on R2A
agar and incubated for 7 days at room temperature. Free- and
total-chlorine concentrations were determined for each group
by using the DPD colorimetric method. All sampling was performed
in triplicate, with the exception of biofilm samples that were
collected in duplicate. All differences for average cell counts
and average chlorine concentrations between sample points were
deemed significant if the
P was <0.05 according to Student's
t-test.
Figure 1A shows planktonic bacterial concentrations in the experimental and control reactors during the 7-day study. Planktonic bacteria were detected at concentrations between 105 and 106 CFU/ml for all groups studied, with the exception of reactors treated with 5.0 mg/liter free-chlorine infeed with and without current application. When compared to each other, these last two groups did not display a significant difference in planktonic bacterial concentrations. Therefore, the application of current had no effect on planktonic bacterial kill rates when current was applied alone to the reactor system or in combination with free-chlorine administration. These trends were also noted in the biofilm bacterial numbers as demonstrated in Fig. 1B. In fact, the application of current significantly increased the number of biofilm bacteria when the current was applied alone and reduced the bactericidal efficacy of the infused free chlorine. This may have been due to the generation of nutrients beneficial to biofilm growth.
The residual-chlorine concentrations in the annular reactors
were determined for each group (Fig.
2). Residual-chlorine concentrations
for reactors that received an infeed of 5.0 mg/liter free
chlorine (with or without bioelectric application) are not provided
in this figure. However, the concentrations in these reactors
ranged between 1.0 and 2.0 mg/liter, and the bioelectric effect-treated
and nontreated reactors did not show a significant difference
in the detected total chlorine concentrations when the reactor
results were compared. All chlorine levels in the four experimental
groups and one control group displayed in Table
1 were less
than 0.06 mg/liter. Specifically, 90% of the 0.5-mg/liter chlorine
infeed was used to satisfy the chlorine demand of the reactors,
as shown by the detection of only 0.06 mg/liter of residual
chlorine. There was also a demonstrable lack of current-generated
reactive chlorine products in the reactor systems. In fact,
when current was applied to the reactor receiving 0.5 mg/liter
infeed, the observed residual-chlorine concentrations were less
than those of reactors that received 0.5 mg/liter infeed alone.
The low residual-chlorine levels in the biofilm-containing reactors
seen in Fig.
2 may be due to inactivation of the chlorine substances
by the biofilm and the adsorbed surface carbon.
The results of the experiments testing the efficacy of the bioelectric
effect ran contrary to those of previous studies that describe
a synergistic effect between weak current fields and antimicrobial
agents (
2,
7,
8,
10,
12). However, those investigators used
pure-culture biofilms under well-defined medium conditions.
Therefore, we feel that the experiments described in our report
more accurately reflect the complex nature of water delivery
systems and their biological/chemical constituents. Current
application was unable to reduce biofilm and planktonic bacterial
concentrations (either with or without free-chlorine addition)
and may in fact increase the bacterial numbers of mixed-species
water biofilm bacteria. When these results are coupled with
the observation that current application resulted in high corrosion
rates on the electrodes and metals that were in contact with
the fluid component of electrically treated reactors (data not
shown), the usefulness of the bioelectric effect as a biofilm
clearance strategy is not evident. The bioelectric effect did
not prove to be a feasible strategy for the clearance of mixed-species
water biofilms in our experimental system.

ACKNOWLEDGMENTS
We thank David Davies, Mark Pasmore, and Bruce McLeod for their
help and consultation in carrying out the studies described
herein. We also thank the American Water Works Association Research
Foundation, the Project Advisory Committee, and the CBE Industrial
Associates for their advice and cooperation in completing this
research.

FOOTNOTES
* Corresponding author. Mailing address: Department of Biomedical Sciences, Dental School, University of MarylandBaltimore, 666 W. Baltimore Street, Baltimore, MD 21201. Phone: (410) 706-2263. Fax: (410) 706-0865. E-mail:
mes003{at}dental.umaryland.edu.


REFERENCES
1 - Butterfield, P. W., A. K. Camper, J. A. Biederman, and A. M. Bargmeyer. 2002. Minimizing biofilm in the presence of iron oxides and humic substances. Water Res. 36:3898-3910.[Medline]
2 - Costerton, J. W., B. Ellis, K. Lam, F. Johnson, and A. E. Khoury. 1994. Mechanism of electrical enhancement of efficacy of antibiotics in killing biofilm bacteria. Antimicrob. Agents Chemother. 38:2803-2809.[Abstract/Free Full Text]
3 - Costerton, J. W., P. S. Stewart, and E. P. Greenberg. 1999. Bacterial biofilms: a common cause of persistent infections. Science 284:1318-1322.[Abstract/Free Full Text]
4 - Curtiss, J. R., and D. Grahn. 1980. Population characteristics and environmental factors that influence level and cause of mortality. A review. J. Environ. Pathol. Toxicol. 4:471-511.
5 - Esrey, S. A., J. B. Potash, L. Roberts, and C. Shiff. 1991. Effects of improved water supply and sanitation on ascariasis, diarrhoea, dracunculiasis, hookworm infection, schistosomiasis, and trachoma. Bull. W. H. O. 69:609-621.[Medline]
6 - Gorter, A. C., P. Sandiford, G. D. Smith, and J. P. Pauw. 1991. Water supply, sanitation and diarrhoeal disease in Nicaragua: results from a case-control study. Int. J. Epidemiol. 20:527-533.[Abstract/Free Full Text]
7 - Jass, J., J. W. Costerton, and H. M. Lappin-Scott. 1995. The effect of electrical currents and tobramycin on Pseudomonas aeruginosa biofilms. J. Ind. Microbiol. 15:234-242.[CrossRef][Medline]
8 - McLeod, B. R., S. Fortun, J. W. Costerton, and P. S. Stewart. 1999. Enhanced bacterial biofilm control using electromagnetic fields in combination with antibiotics. Methods Enzymol. 310:656-670.[Medline]
9 - Murray, C. J., and A. D. Lopez. 1997. Global mortality, disability, and the contribution of risk factors: Global Burden of Disease Study. Lancet 349:1436-1442.[CrossRef][Medline]
10 - Stewart, P. S., W. Wattanakaroon, L. Goodrum, S. M. Fortun, and B. R. McLeod. 1999. Electrolytic generation of oxygen partially explains electrical enhancement of tobramycin efficacy against Pseudomonas aeruginosa biofilm. Antimicrob. Agents Chemother. 43:292-296.[Abstract/Free Full Text]
11 - Stoodley, P., D. de Beer, and H. M. Lappin-Scott. 1997. Influence of electric fields and pH on biofilm structure as related to the bioelectric effect. Antimicrob. Agents Chemother. 41:1876-1879.[Abstract]
12 - Wellman, N., S. M. Fortun, and B. R. McLeod. 1996. Bacterial biofilms and the bioelectric effect. Antimicrob. Agents Chemother. 40:2012-2014.[Abstract]
Applied and Environmental Microbiology, October 2005, p. 6379-6382, Vol. 71, No. 10
0099-2240/05/$08.00+0 doi:10.1128/AEM.71.10.6379-6382.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.