15 to 25 nucleotides [nt]) with complementary sequences to targets. After hybridization and a brief washing, the microchip is covered with a transparent chamber containing the proper washing solution and placed on the top of a heating device underneath a microscopy-based imaging system (9, 14). The microchip is subsequently subjected to thermal heating from low to high (i.e., from 10 to 80°C at a 1 to 2°C increment per min) to gradually denature the target-probe duplexes. By quantifying the respective fluorescent intensities of all spots on the array at every temperature, dissociation curves of all duplexes can be plotted based on the measured fluorescent intensities, and Tds of all duplexes can be calculated in a single experiment. This melting approach has shown promising results to correctly identify targets based on differences in Td and minimize false-positive signals in DNA microarray studies but will require further optimization and development before being extensively applied in microbial-community analysis. Recent reports (4, 6, 12) suggested that different fluorescent dyes can exhibit different stabilities and intensities with respect to the changes of external parameters, such as solution temperature. This temperature dependency can further affect the hybridization intensity, dissociation curves, and Td measurement during melting curve analysis in microarray studies (5) but apparently has not been taken into consideration in past studies (2, 3, 9, 14). To address this issue, the fluorescence characteristics of eight commonly used fluorophores (Table 1) were systematically investigated with respect to changes in temperature, salt concentration, and formamide concentration using gel-based microchips in this study.
|
View this table: [in a new window] |
TABLE 1. Fluorophore excitation/emission characteristics and filters used in this study
|
Furthermore, DNA microchips comprising polyacrylamide gel pad matrices with dimensions (width by length by depth) of 300 by 300 by 10 µm and a center-to-center spacing of 500 µm were fabricated as described previously (11). Oligonucleotide probes (0.5 pmol) and control probes (0.1 pmol) were printed in four replicates onto individual gel pad elements using the Biochip arrayer (Packard, Perkin-Elmer). Subsequently, the printed microchips were stabilized using pyridine-borane complex and treated with sodium borohydride solution to reduce background fluorescence. The microchips were washed in distilled water for 30 min, dried using a nitrogen stream, and preserved in a dark, dust-free environment before use.
The effects of temperature, salt concentration, and formamide concentration on the emission intensities of different fluorophore-labeled control probes were first investigated. The region immobilized with the control probes on the microchip was covered with a microchamber containing 50 µl of buffer solution at 4°C. The buffer solution contained 20 mM of Tris-HCl (pH 8.0), 5 mM of EDTA, and different concentrations of NaCl (10, 100, and 500 mM) and formamide (0, 10, 20, and 30%). The assemblage was mounted onto a Peltier thermal stage under a microscopy-based imaging system (8) and heated stepwise from 7.5 to 80°C at an increment of 2.5°C per 3 min. Fluorescent images at the end of each holding interval were captured with an exposure time of approximately 800 ms under either a Cy3 filter (excitation/emission wavelength, 555/610 nm) or a green fluorescence protein (GFP) filter (470/525 nm) (Table 1) through an image acquisition and analysis program, LabArray (http://www.eng.nus.edu.sg/civil/Labarray/labarray .htm) (10). In brief, after capture of the first image at the starting temperature, all probe spots or areas of interest were identified and located with grids. The fluorescence intensities of individual areas of interest at each temperature were then quantified, subtracted from the background, and exported into a Microsoft Excel spreadsheet. Subsequently, a user could obtain the fluorescence intensity curves for individual probes with respect to temperature change after averaging the intensities of all replicates at each temperature. Since individual fluorophores were subjected to light exposure for less than 23 to 25 s, no significant photobleaching was observed with individual fluorophores (data not shown).
Figure 1 shows the effects of temperature and salt concentration on fluorophore stabilities on gel-based microchips. Texas Red, Oregon Green, and FAM (carboxyfluorescein) did not exhibit temperature-dependent characteristics within the range of temperature tested at a salt concentration of 500 mM. In contrast, the remaining five fluorophores were greatly affected by the increase in temperature, with a reduction in fluorescence intensity larger than 56 to 82% of the initial values measured at 7.5°C at a salt concentration of 500 mM. Furthermore, all fluorophores were observed to exhibit different dependencies to salt concentrations (10, 100, and 500 mM). For Texas Red, rhodamine red, TAMRA (tetramethylrhodamine), and Cy3, the reductions in fluorescent intensities were lower at low salt concentrations than at high salt concentrations. For FAM, the reduction in fluorescent intensity was higher at a 10 mM salt concentration than at 100 mM and 500 mM salt concentrations only when the temperature was greater than 40°C. For fluorescein isothiocyanate (FITC), the reduction in fluorescence intensity was slightly higher at a 10 mM concentration than at high salt concentrations. Oregon Green and Cy2 exhibited irregular emission behavior to low salt concentrations. Changes in formamide concentrations (10, 20, and 30%) did not result in significant changes in the fluorescence signals of the fluorophore dyes (the standard deviation [SD] was less than ±5% of the intensity observed at individual temperatures) (data not shown).
![]() View larger version (24K): [in a new window] |
FIG. 1. Effects of salt concentration on fluorophore stabilities with respect to temperature on gel-based microchips. The formamide concentration in the buffer was fixed at 0%. (A) Cy3 filter (excitation, 555/50 nm; 610/75 nm); (B) GFP filter (excitation, 470/40 nm; emission, 525/50 nm).
|
Figure 2A shows the melting curves of the PM duplex after it was hybridized with Texas Red- and Cy3-labeled oligonucleotide targets separately. The melting curves for those two duplexes were expressed as the percentage of raw fluorescent intensities observed at the starting temperature (i.e., 15°C). Due to the temperature-associated behavior, both melting curves were distinctly different, with a difference in Td close to 15°C. The melting curve for the Texas Red-labeled target exhibited a typical S-shaped curve for DNA duplex dissociation, and that for the Cy3-labeled target showed a linear decrease. In order to obtain consistent melting curves for both types of fluorophore-labeled targets, a normalization step could be introduced by correcting the raw fluorescent intensities against the measured fluorescent intensities of a control probe attached with the same dye as that of the target (Fig. 2B). To do so, raw fluorescent intensities of probes obtained from an experiment with a specific fluorescently labeled target were first normalized with the respective control probe labeled with the same fluorophore spots at each corresponding temperature using equation 1:
![]() | (1) |
![]() | (2) |
![]() View larger version (24K): [in a new window] |
FIG. 2. Melting curves of PM BC probe-target duplexes. (A) Texas Red- and Cy3-labeled targets without normalization (signal intensity at the initial temperature was set to 1); (B) Texas Red-, Cy3-, rhodamine red-, and TAMRA-labeled targets normalized against control probes labeled with the same fluorophores. The formamide and salt concentrations in the wash buffer were fixed at 0% and 50 mM, respectively. The key in panel B indicates the fluorophore-labeled target or the type of fluorophore-labeled control probe used for normalization.
|
The temperature dependency effect of fluorophores on mismatch discrimination during melting curve analysis on microchips was further examined (Table 2). Among the four fluorophores tested, the observed Tds for the PM duplexes higher than after correct normalization were 3.98 to 5.0°C (SD = 0.37 to 0.61°C) one-MM duplexes and 10.3 to 12.3°C (SD = 0.24 to 1.03°C) higher than the two-MM duplex. These results suggested that correct normalization was also necessary to achieve MM discrimination.
|
View this table: [in a new window] |
TABLE 2. Tds of PM duplexes and Tds between MM duplexes and the PM duplex under different fluorophore labeling conditionsa
|
Furthermore, the emitted fluorescence intensities-versus-temperature graphs were useful in facilitating the selection of fluorophore labels in future microchip experiments with dual-color labeling. The selection of fluorophore labels with similar emission characteristics with respect to changes in external experimental conditions, such as temperature, salt concentration, and formamide concentration, is preferable in order to minimize any dye-associated bias during the comparison of results from hybridization experiments employing dual-color labeling. When two fluorophore labels that possess different emission characteristics with respect to external working conditions are used, correction factors for individual labels can be obtained based on respective calibration curves similar to those in Fig. 1 and can be introduced to eliminate any dye-associated bias. It is also possible to use fluorophores with linear temperature dependency as temperature sensors in microfluidic devices where temperature monitoring by physical instruments is difficult (12).
In summary, we have demonstrated the changes in emission characteristics of various commonly used fluorescent labels with respect to important hybridization parameters (e.g., temperature and salt concentration). Although the exact reasons for the difference in fluorescence emission characteristics among those fluorophores were not clear, the proposed normalization could facilitate a fair comparison among different dissociation curves obtained during melting curve analysis on DNA microchips.
|
|
|---|