Previous Article | Next Article ![]()
Applied and Environmental Microbiology, December 2005, p. 8069-8076, Vol. 71, No. 12
0099-2240/05/$08.00+0 doi:10.1128/AEM.71.12.8069-8076.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.
Thayer School of Engineering,1 Department of Biological Sciences, Dartmouth College, Hanover, New Hampshire 037552
Received 27 June 2005/ Accepted 14 August 2005
|
|
|---|
12 kV/cm, and ET was only observed above the same threshold. Similarly, for T. saccharolyticum, oscillations were only observed at field strengths of
10 kV/cm, and ET was only observed above the same threshold. When a passive electrical filter consisting of an inductor and resistor in parallel was added to the system to prevent the development of oscillations, ET efficiencies were reduced dramatically for all three strains at all field strengths tested. The maximum tested field strength, 25 kV/cm, resulted in the maximum measured transformation efficiency for all three strains. At this field strength, the efficiency of ET in the absence of oscillations was decreased compared to that observed in the presence of oscillations by 500-fold for C. thermocellum ATCC 27405, 2,500-fold for C. thermocellum DSM 1313, and 280-fold for T. saccharolyticum. Controls using the same apparatus with Escherichia coli cells or a resistor with a value representative of the direct current resistance of typical cell samples did not develop oscillations, and ET efficiencies obtained with E. coli were the same with or without the electrical filter included in the pulse generator circuit. The results are interpreted to indicate that spontaneously arising oscillations have a large beneficial effect on transformation efficiency in the system employed here and that the development of oscillations in this system is affected by the cell species present. |
|
|---|
Thermophilic, anaerobic, saccharolytic bacteria are of interest in the context of cellulosic biomass fermentation in both biotechnological processes and natural environments (1, 4-9, 15). In particular, cocultures of the cellulolytic Clostridium thermocellum with noncellulolytic thermophiles capable of using xylose and other hemicellulose-derived sugars have been proposed for the conversion of all fermentable biomass components to ethanol (7, 8, 13, 16). Recently, we reported electrotransformation (ET) of Clostridium thermocellum DSMZ 1313 with an efficiency of 2 x 105 transformants µg1, using a custom pulse generator and cuvette design (17). The conditions optimized for C. thermocellum DSMZ 1313 were also shown to result in an ET efficiency of 5 x 104 transformants µg1 for strain ATCC 27405. Mai and Wiegel reported (11), and subsequently improved (10), an electrotransformation protocol for the xylan-utilizing noncellulolytic thermophile Thermoanaerobacterium saccharolyticum JW/SL-YS 485, resulting in transformation efficiencies of
1 x 103 transformants µg1 DNA.
We report here that current oscillations with a frequency of
24 MHz are observed during ET of both C. thermocellum and T. saccharolyticum when a square, non-oscillatory input signal is used to control a pulse generator (19, 22), using a previously reported ET protocol (17). Spontaneous (i.e., not applied externally) current oscillations at much lower frequencies have been observed in prior studies using the same circuit and cuvette design, with
100-kHz oscillations observed for Clostridium acetobutylicum ATCC 824 (18) and
17-kHz oscillations observed for Corynebacterium glutamicum ATCC 13032 (19). Externally applied oscillatory electrical pulses were shown to be effective for ET of C. acetobutylicum, with the ET efficiency being a strong function of the frequency (18). Externally applied oscillatory pulses have also been used for ET of other microorganisms (14) and mammalian cells (3, 23).
The objectives of this study are to report improved ET conditions for C. thermocellum and T. saccharolyticum, to characterize the current oscillations observed during ET of both of these organisms, and to evaluate the significance of these oscillations. Specific questions to be answered in this work include the following. Does the appearance of oscillations depend on the species of microbe being tested? How does the magnitude of applied voltage impact the appearance and features of oscillations? Is there a relationship between the appearance of oscillations and conditions that result in successful ET? If oscillations are prevented from occurring, is the efficiency of ET impacted?
|
|
|---|
|
View this table: [in a new window] |
TABLE 1. Bacterial strains used for this study
|
Electrotransformation.
A custom-built pulse generator featuring the cell sample in series with other circuit elements as well as custom-built cuvettes was used as described elsewhere (17). The cultivation of anaerobic thermophiles prior to ET, pulse application, postpulse sample processing, and determination and analysis of cell viability were performed as described previously (17), with the following modification: prior to ET, overnight cultures were diluted 1:7 to 1:10 instead of 1:3 with sterile prewarmed (58°C) DSM 122-cellobiose broth containing 20 µg ml1 of isoniazid (Sigma, St. Louis, MO). The duration of the electrical pulse applied was as indicated previously. The preparation of E. coli cells for ET and the selection of recombinants were performed as described elsewhere (20). Cell suspensions of thermophilic anaerobes or E. coli contained approximately 9 x 1010 cells ml1 and were kept on ice until use. For cell-free controls, cell suspensions were replaced either by high-performance liquid chromatography (HPLC)-grade water (Sigma, St. Louis, MO) or by a set of three low-inductance 10-k
resistors (TO 220 style thick film power resistors; Ohmite Mfg. Co., Rolling Meadows, IL) (cell sample resistive equivalent) connected in series. As described previously (17), ET was carried out using 90 to 100 µl of cell suspension in 2.0-ml disposable centrifuge tubes with 305 stainless steel electrodes and a single square input pulse of 10 ms. For experiments aimed at investigating the importance of induced oscillations with respect to ET, we used a custom-built linear filter composed of TO 220 style thick film power resistors (Ohmite Mfg. Co., Rolling Meadows, IL) with a total resistance of 29 k
in parallel with a toroidal 107-µH filter inductor (Magnetek, Inc., Los Angeles, CA). The filter was switched in series with the other elements of the above power circuit so that it could be bypassed to eliminate the filtering effect on the pulse current (Fig. 1).
![]() View larger version (20K): [in a new window] |
FIG. 1. Schematic diagram of the custom-built generator featuring a passive in-line filter.
|
|
|
|---|
The revised preferred conditions found to be effective for these two C. thermocellum strains were also evaluated for ET of Thermoanaerobacterium saccharolyticum YS 485, using pIKM1 with selection based on kanamycin resistance. T. saccharolyticum was readily transformed [(7.42 ± 0.19) x 105 transformants µg1 DNA at 25 kV/cm] under these conditions, without further optimization. The transformation of T. saccharolyticum was confirmed by PCR and plasmid rescue experiments (data not shown) similar to those we described previously (17).
Observation of current oscillations during electrotransformation.
During monitoring of the pulse current, rapid variations of the current over time were observed for C. thermocellum ATCC 27405 (Fig. 2A), T. saccharolyticum YS 485 (Fig. 2B), and C. thermocellum DSM 1313 (data not shown). Adjusting the oscilloscope timescale revealed regular oscillations with a frequency of 24.14 MHz, as shown in Fig. 2C for C. thermocellum ATCC 27405. An oscillation frequency of 24.14 MHz was also observed with C. thermocellum DSM 1313 and T. saccharolyticum YS 485 (data not shown). Although the appearance and magnitude of oscillations were subsequently found to depend on the magnitude of the voltage applied to samples, the frequency of oscillation was unchanged for all conditions under which oscillations were observed for the three thermophilic strains investigated.
![]() View larger version (68K): [in a new window] |
FIG. 2. Voltage versus time plots obtained during application of an electrical pulse to various samples. Voltage was measured at the 20- pulse current sensor. Vertical scale, 5 V/division; horizontal scale, 2 ms/division, except in panel C. (A) C. thermocellum ATCC 27405; (B) T. saccharolyticum YS 485; (C) image A, with a horizontal scale of 20 ns/division. Controls contained the indicated components instead of a sample containing cells of a thermophilic anaerobe. (D) 50-k resistor; (E) cuvette filled with HPLC-grade water; (F) E. coli Top 10 in HPLC-grade water.
|
Investigation of current oscillations and ET efficiency as a function of electric field strength.
The ET efficiency was investigated in relation to the electric field strength, with all parameters but the field strength maintained at the revised preferred conditions identified above. For C. thermocellum ATCC 2704, a minimum field strength of 12 kV/cm was required before transformation was observed, with progressively higher transformation efficiencies observed up to the maximum field strength tested, 25 kV/cm (Fig. 3). The current passing through cell samples during pulse application was measured at all field strengths for which the transformation efficiency was evaluated, with data for only selected field strengths shown. A one-to-one correspondence between successful ET and the appearance of oscillations was observed. In particular, oscillations were not evident for field strengths of 11 kV/cm (Fig. 3B, panel 1) or lower, at which transformation did not occur, but were observed for field strengths from 12 kV/cm (Fig. 3B, panel 2) to 25 kV/cm (Fig. 3B, panel 3), at which transformation did occur. C. thermocellum DSM 1313 also exhibited a minimum field strength of 12 kV/cm in order for transformation to occur as well as a one-to-one correspondence between successful ET and the appearance of oscillations (data not shown).
![]() View larger version (36K): [in a new window] |
FIG. 3. Transformation efficiency and appearance of spontaneous oscillations in relation to field strength for ET of C. thermocellum ATCC 27405. (A) ET efficiency. (B) Oscillations for field strengths of 11 kV/cm (1), 12 kV/cm (2), and 25 kV/cm (3). Vertical scale, 5 V/division; horizontal scale, 2 ms/division.
|
10 kV/cm (Fig. 4 A), at which high-frequency current oscillations were observed (Fig. 4B, panels 2 and 3). For field strengths of <10 kV/cm, neither oscillations nor transformation was observed (Fig. 4B, panel 1).
![]() View larger version (47K): [in a new window] |
FIG. 4. Transformation efficiency and appearance of spontaneous oscillations in relation to field strength for ET of T. saccharolyticum YS 485. (A) ET efficiency. (B) Oscillations for field strengths of 9 kV/cm (1), 10 kV/cm (2), and 25 kV/cm (3). Vertical scale, 5 V/division; horizontal scale, 2 ms/division.
|
![]() View larger version (33K): [in a new window] |
FIG. 5. ET efficiency in relation to field strength in the presence and absence of high-frequency oscillations for ET of C. thermocellum ATCC 27405. (A) Transformation efficiencies. Symbols: , efficiency without in-line filter preventing high-frequency oscillations; , efficiency with in-line filter. (B) Voltage traces during pulse application at 25 kV/cm without in-line filter (1) and with in-line filter (2). Vertical scale, 5 V/division; horizontal scale, 2 ms/division.
|
![]() View larger version (52K): [in a new window] |
FIG. 6. ET efficiency in relation to field strength in the presence and absence of high-frequency oscillations for ET of C. thermocellum DSM 1313. (A) Transformation efficiencies. Symbols: , efficiency without in-line filter preventing high-frequency oscillations; , efficiency with in-line filter. (B) Voltage traces during pulse application at 25 kV/cm without in-line filter (1) and with in-line filter (2). Vertical scale, 5 V/division; horizontal scale, 2 ms/division.
|
![]() View larger version (45K): [in a new window] |
FIG. 7. ET efficiency in relation to field strength in the presence and absence of high-frequency oscillations for ET of T. saccharolyticum YS 485. (A) Transformation efficiencies. Symbols: , efficiency without in-line filter preventing high-frequency oscillations; , efficiency with in-line filter. (B) Voltage traces during pulse application at 25 kV/cm without in-line filter (1) and with in-line filter (2). Vertical scale, 5 V/division; horizontal scale, 2 ms/division.
|
|
|
|---|
These observations establish that oscillations are correlated with high-frequency transformation for the organisms and electrical circuit studied. Our results are also consistent with, but do not prove, the existence of a common factor underlying both efficient transformation and the development of current oscillations. Successful ET requires that both electrical and biological variables be within acceptable ranges. We suspect that monitoring the current during pulse application may provide an indication of cell membrane electropermeabilization, which can be evaluated independently of biological variables such as restriction/modification systems, plasmid replication, and functional expression of selective markers.
Further work is needed to explain the origin of the observed oscillations. Oscillations are possible in similar circuits with no bacterial cells due to parasitic inductances and capacitances in the wiring and in the circuit elements in conjunction with the explicit circuit elements and the gain of the tetrode. However, our results show that the appearance of oscillations is dependent on the species of bacterium present under the conditions investigated. Cells of both T. saccharolyticum and C. thermocellum provided similar oscillation patterns at and above the threshold electric field strengths of 10 and 12 kV/cm, respectively. In contrast, we were not able to observe an excitation of oscillations when E. coli was substituted for thermophilic anaerobes at all electric field strengths tested. In addition, no current oscillations were detected when the cell sample was replaced with its resistive equivalent or with HPLC-grade water. Thus, we can conclude that the electrical characteristics of the cell samples play an important role in the appearance of the spontaneous oscillations observed. These electrical characteristics may include nonlinear and/or time-varying behavior that cannot be characterized by a linear time-invariant network or impedance.
In previous work using the same pulse generator employed herein, Tyurin et al. (18) reported oscillations of C. acetobutylicum ATCC 824 at about 100 kHz. When the circuit was modified to apply a range of selected frequencies to the sample, the ET efficiency peaked at 100 kHz. These results indicate that the frequency of spontaneously occurring current oscillations obtained with the pulse generator used herein is related to electroporation or associated biological phenomena and that these oscillations are a determinant of ET efficiency. Experiments involving externally imposed oscillatory signals would be very informative to undertake with the thermophilic strains investigated in this study, and they are being planned but are more demanding to perform because of the higher frequencies involved. The prior study of Tyurin et al. also reported the release of numerous intracellular membrane vesicles under conditions resulting in spontaneous oscillations and successful ET. Many gram-positive bacteria have a complex intracellular morphology. In particular, bacteria of the genus Clostridium feature prespores in most vegetative cells, as well as additional intracellular membrane structures (2, 18). E. coli, which does not form spores, has a relatively simple intracellular morphology in comparison. We are intrigued by the possibility that when cell membranes are electropermeabilized, intracellular membrane structures of cells of certain bacterial species become exposed to the applied electric field through the electropores in the membrane, resulting in dynamic changes in the impedance of cell samples.
Much remains to be done to elucidate the mechanism and significance of spontaneous oscillations accompanying high-efficiency ET of certain thermophilic anaerobes. There appears to be ample incentive to undertake studies directed toward this end in light of the interesting fundamental questions involved, several indications that the appearance of oscillations is closely associated with high-frequency transformation, and the difficulty and desirability of gene transfer to many microorganisms.
We are grateful to Gunter A. Hoffman and Genetronics, Inc., for giving the custom-built generator to M.V.T.
|
|
|---|
3T I methyltransferase to protect plasmids from restriction upon transformation of Clostridium acetobutylicum ATCC 824. Appl. Environ. Microbiol. 59:1077-1081.
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»