Elimination of Botulinum Neurotoxin (BoNT) Type B from Drinking Water by Small-Scale (Personal-Use) Water Purification Devices and Detection of BoNT in Water Samples
Ari Hörman,1,2*
Mari Nevas,1
Miia Lindström,1
Marja-Liisa Hänninen,1 and
Hannu Korkeala1
Department of Food and Environmental Hygiene, Faculty of Veterinary Medicine, University of Helsinki, Helsinki,1
Medical School, The Finnish Defense Forces, Lahti, Finland2
Received 7 August 2004/
Accepted 28 October 2004

ABSTRACT
Seven small-scale drinking water purification devices were evaluated
for their capacity to eliminate botulinum neurotoxin (BoNT)
type B from drinking water. Influent water inoculated with toxic
Clostridium botulinum cultures and effluent purified water samples
were tested for the presence of BoNT by using a standard mouse
bioassay and two commercial rapid enzyme immunoassays (EIAs).
The water purification devices based on filtration through ceramic
or membrane filters with a pore size of 0.2 to 0.4 µm
or irradiation from a low-pressure UV-lamp (254 nm) failed to
remove BoNT from raw water (reduction of <0.1 log
10 units).
A single device based on reverse osmosis was capable of removing
the BoNT to a level below the detection limit of the mouse bioassay
(reduction of >2.3 log
10 units). The rapid EIAs intended
for the detection of BoNT from various types of samples failed
to detect BoNT from aqueous samples containing an estimated
concentration of BoNT of 396,000 ng/liter.

INTRODUCTION
Data on the purification capacities of various water purification
devices and techniques are essential for the assessment of drinking
water safety. Water sources and drinking water supply systems
can become fecally contaminated but may also be targets for
bioterrorism or sabotage (
8,
9,
20,
22). Botulinum neurotoxins
(BoNT; types A to G) produced by
Clostridium botulinum and by
some other related clostridia are the most potent biotoxins
known, and as tasteless and odorless lethal compounds they would
generate great concern if weaponized (
5,
13,
27).
Several small-scale devices from different manufacturers are commercially available for drinking water purification. These devices, mostly based on filtration through ceramic or membrane filters, are needed especially by soldiers, hikers, or workers of aid organizations operating in primitive wilderness or under disaster conditions (6). Similar filters are also marketed for point-of-use in single households. To ensure consumer safety, it is essential to compare the microbial and chemical purification capacities of different devices through independent evaluation tests (12, 23). Data are available on the purification capacity of some filters, but usually these data are based on the capacity of the filters to remove microbial organisms, e.g., Escherichia coli, coliforms, or Cryptosporidium oocysts (15, 26, 28). There are some reports in which water purification devices or techniques were tested for elimination of microbial toxins, mainly cyanobacterial toxins (1-3, 17, 18, 25, 29, 33).
Free chlorine at a concentration of 5 mg/liter of water (5 ppm) for 30 min (32) and heating water at 80°C for 30 min (19) were shown to be effective for inactivation of BoNT. Assumptions on the capacity of reverse osmosis to remove BoNT from drinking water have been made (32), but no research to test this capacity has been performed. Reverse osmosis is assumed to eliminate BoNT effectively based of the 150-kDa molecular size of the toxin.
Rapid and sensitive tests are needed for BoNT detection under field conditions as well as for rapid screening of suspect samples (7). At present, the few rapid tests available have not shown sufficient sensitivity or specificity to replace the standard mouse bioassay, which remains the only standard method available for BoNT detection (4, 34). Apart from being time-consuming, the mouse bioassay poses ethical, economic, and safety concerns. Some enzyme-linked immunosorbent assays and enzyme immunoassays (EIAs) are available that show sensitivity similar to sensitivity level of the mouse bioassay (10, 11, 16, 35).
The aim of the present study was to obtain data on the capacity of commercial water purification devices based on various methods to eliminate BoNT from intentionally contaminated drinking water. Furthermore, two commercially available rapid EIAs for BoNT detection were evaluated in comparison to the standard mouse bioassay.

MATERIALS AND METHODS
Inoculated raw water.
A total of 70 liters of tap water from the municipal drinking
water supply system of Helsinki was stored in an open plastic
container for 24 h to reduce the free chlorine concentration.
Seven proteolytic
C. botulinum strains producing BoNT type B
(Table
1) were cultured separately in 100 ml of tryptone-peptone-glucose-yeast
extract liquid broth medium (Oxoid Ltd., Basingstoke, Hampshire,
United Kingdom) anaerobically at 37°C for 72 ± 2
h, followed by subculture at 37°C for 16 h. The broth cultures
(seven cultures, 100 ml each) were added to the tap water (influent
water).
Water purification devices and testing.
The water purification devices were selected from among commercially
available products based partly on the suitability for field
operation. Six devices, representing various types of filters
and purification methods, were selected from four manufacturers
(Table
2). In addition, an experimental sand filter was developed
(Table
2). All devices were portable (weight, <10 kg) and
functional without electricity or chemical supplementation.
The devices were used manually according to the instructions
of the manufacturer. Prior to use, each device was rinsed with
1 to 2 liters of sterile water. A total of 3 liters of purified
effluent water was produced with each device from inoculated
influent water. The purified effluent water samples were collected
in sterile glass bottles for further investigation.
Sampling.
From the inoculated influent water the following samples were
taken prior to using the purification devices: a 100-ml sample
for total aerobic bacterial count; a 200-ml sample for total
and free chlorine, conductivity, and pH analyses; and two 200-ml
samples for BoNT analyses. From the purified effluent water
produced by each device, a 100-ml sample for total aerobic bacterial
count, a 200-ml sample for conductivity and pH, and two 200-ml
samples for BoNT analyses were taken.
Bacteriological and physicochemical analysis.
As a process indicator, the total aerobic count was analyzed by using 3 M Petrifilm aerobic count plates (3M Corp., St. Paul, Minn.) of 1-ml influent and effluent water samples. The plates were incubated at 35°C for 24 ± 2 h. Free and total chlorine were analyzed by using the Spectroquant Colorimeter Picco Cl2 spectrophotometer (Merck KGaA, Darmstadt, Germany). Temperature (Delta Ohm HD8601P; Padua, Italy), pH (Eutech Cybernetics pHScanWP2; Singapore, Republic of Singapore), and conductivity (HACH Model C0150 conductivity meter; Loveland, Colo.) were measured with portable devices.
BoNT analysis.
BoNT was analyzed by using a mouse bioassay (24, 31) with the permission of the State Provincial Office of Southern Finland. Samples from influent water inoculated with toxic C. botulinum cultures and purified effluent waters were sterile filtered through 0.45-µm-pore-size bacteriological membrane filters and diluted 10-fold (101, 102, 103, 104, and 105). One undiluted sample from inoculated influent water was heated at 100°C for 10 min to destroy the toxin prior to testing for possible nonspecific reactions in the mouse bioassay. A 0.8-ml volume of each undiluted and diluted sample and of heated sample was injected intraperitoneally into two 20-g laboratory mice. The mice were observed for typical symptoms of botulism for 4 days. The test results were used to estimate the BoNT concentration in the water samples and a 50% lethal dose of 1.2 ng of BoNT type B per kg of body weight was used in this estimation (13).
Two commercial rapid EIAs (Bot Tox BioThreat Alert Test Strip, Tetracore, Inc., Gaithersburg, Md., and BADD BoNT Rapid Detection Kit, Osborn Scientific Group, Lakeside, Ariz.) were used to further analyze the undiluted and diluted samples of inoculated influent water and undiluted samples of purified effluent water. The tests were qualitative and based on the use of dye-labeled anti-botulinum toxin antibodies, which in the presence of BoNT were intended to appear as visible colored lines. Both tests were performed according to the manufacturers' instructions. A 0.5-ml volume of sample was diluted with 0.5 ml of the buffer solution provided with the test kits, and a 0.15-ml volume of this dilution was dispensed onto the sample port of the test strips. The tests were interpreted as positive if two colored lines appeared in the test strip within 15 min: one in the test or sample location and one in the control location. The tests were interpreted as negative if only the control line appeared and as invalid if no line appeared at the control location.
Determination of purification capacities.
The purification capacities of the devices were calculated as logarithmic (log10) reductions in concentrations of analyzed parameters (total aerobic count, conductivity, and estimated concentration of BoNT) between undiluted inoculated influent water and undiluted purified effluent water samples. The reduction in log10 units was calculated by using the following formula: log10 reduction = log10 (Ni/Ne), where Ni is the concentration in influent water before purification and Ne is the concentration in purified effluent water after purification.
If no aerobic bacteria were detected in the undiluted purified effluent water sample, the log10 reduction was estimated by using an aerobic bacteria count of 1 CFU/ml of sample. If the mouse bioassay was negative for BoNT in the undiluted purified effluent water sample, the maximum concentration of BoNT in the sample was estimated by using the detection limit of the mouse bioassay and the log10 reduction calculated as above.

RESULTS
Two of the water purification devices tested were able to eliminate
some or all of the BoNT type B from the inoculated influent
water (Tables
3 and
4). The device based on reverse osmosis
removed >2.3 log
10 units of BoNT to the level below the detection
limit of the mouse bioassay, and the experimental sand filter
reduced the level of toxin by 0.3 to 1.3 log
10 units. The devices
based merely on physical filtration through ceramic or membrane
filters through 0.2- to 0.4-µm pores were not able to
remove BoNT from the inoculated influent water (reduction, <0.1
log
10 units), nor was UV irradiation from the low-pressure lamp
able to destroy the toxin. All purification devices except for
the sand filter reduced the level of total aerobic count from
the inoculated water by >3.3 log
10 units (sand filter, reduction
by 0.8 log
10 units). The device based on reverse osmosis was
the only device able to reduce conductivity during the purification
process (reduction by 1.6 log
10 units). The total aerobic count
in the inoculated influent water was 2,000 CFU/ml of water,
conductivity was 322.2 µS/cm, and the concentration of
free and total chlorine was <0.01 mg/liter.
View this table:
[in this window]
[in a new window]
|
TABLE 3. Detection of botulinum toxin type B in C. botulinum culture broth, inoculated influent water, and purified effluent waters
|
The results for detection of BoNT with the standard mouse bioassay
and commercial rapid tests are presented in Table
3. The BoNT
concentrations were extrapolated from the mouse bioassay results
to be in the range of 3,960 to 5,985 ng/liter in undiluted inoculated
influent water and 100-fold higher in the tryptone-peptone-glucose-yeast
extract broth used for inoculating the influent water. Both
commercial rapid EIA kits determined that all the samples that
were positive in the mouse bioassay were negative for BoNT.
All samples negative in the mouse bioassay were also negative
in the rapid EIAs.

DISCUSSION
The testing of the water purification devices produced information
crucial to the assessment of drinking water safety and security.
Based on the present study and some suggestive results from
earlier studies (
18), the only technique available for portable
devices capable of eliminating BoNT from drinking water is reverse
osmosis. To some extent sand filtration could be effective in
reducing BoNT concentration, as suggested here as well as in
studies on microcystin removal, but this most probably is strongly
dependent on the thickness of the sand bed and properties of
the sand used (
21,
25).
In the present study, the 254-nm UV irradiation produced by the low-pressure lamp was not able to degrade BoNT in the water. Some studies indicated that direct sunlight can degrade BoNT by 90% in 1 h and 100% in 3 h (30). The degradation process probably required broad-spectrum UV irradiation coupled with oxidative spectrum produced by high-pressure UV lamps. Activated carbon combined with filtration through ceramic filters did not affect toxin removal in this study. A single previous study showed activated carbon to be effective against BoNT type A in water samples (14), but the removal was apparently due to the amount and type of activated carbon used as well as to the flow rate of the water and contact time with the carbon. In the present study, the activated carbon was either in the form of a thin layer or in a relatively small cartridge. Taking into account the purification techniques of individual filters, the results of aerobic bacteria removal and reduction in conductivity coincided with their theoretical purification capacities and with the results of earlier studies on some other drinking water purification filters (18, 28).
The rapid EIAs for detection of BoNT showed poor performance compared with the results of the standard mouse bioassay. Even the broth with toxic C. botulinum cultures at estimated BoNT concentrations of 396,000 to 598,500 ng/liter appeared to be negative for BoNT when evaluated with the rapid tests. It can be estimated from the toxicological data that only 1.2 to 1.8 ml of this broth constitutes the oral lethal dose for a 70-kg human being (4, 13, 27). The failure to detect BoNT is unexpected, since the estimated concentration of BoNT in this test was similar to or higher than the detection limits of the tests reported by the manufacturers. The intentional contamination of drinking water and water supply systems will apparently result in concentrations remarkably lower in distributed drinking water than in pure bacterial culture (8). However, the total intake of the toxin can still cause symptoms or death due to the total amount of water ingested. Therefore, the usefulness of these rapid tests is very limited due to their high detection limit and failure to detect lethal concentrations of toxin in drinking water. The negative test results will be misleading and may result in casualties if BoNT is intentionally released into drinking water supplies.

ACKNOWLEDGMENTS
This work was supported by study grant Mdd587 from the Finnish
Scientific Advisory Board for Defense, Ministry of Defense,
Finland.

FOOTNOTES
* Corresponding author. Mailing address: Department of Food and Environmental Hygiene, Faculty of Veterinary Medicine, University of Helsinki, P.O. Box 57, 00014 Helsinki University, Finland. Phone: 358 40 5560851. Fax: 358 9 19149718. E-mail:
ari.horman{at}milnet.fi.


REFERENCES
1 - Alam, Z. B., M. Otaki, H. Furumai, and S. Ohgaki. 2001. Direct and indirect inactivation of Microcystis aeruginosa by UV-radiation. Water Res. 35:1008-1014.[Medline]
2 - Anderson, W. B., P. M. Huck, D. G. Dixon, and C. I. Mayfield. 2003. Endotoxin inactivation in water by using medium-pressure UV lamps. Appl. Environ. Microbiol. 69:3002-3004.[Abstract/Free Full Text]
3 - Anderson, W. B., C. I. Mayfield, D. G. Dixon, and P. M. Huck. 2003. Endotoxin inactivation by selected drinking water treatment oxidants. Water Res. 37:4553-4560.[Medline]
4 - Arnon, S. S., R. Schechter, T. V. Inglesby, D. A. Henderson, J. G. Bartlett, M. S. Ascher, E. Eitzen, A. D. Fine, J. Hauer, M. Layton, S. Lillibridge, M. T. Osterholm, T. O'Toole, G. Parker, T. M. Perl, P. K. Russell, D. L. Swerdlow, and K. Tonat. 2001. BoNT as a biological weapon: medical and public health management. JAMA 285:1059-1070.[Abstract/Free Full Text]
5 - Atlas, R. M. 1998. The medical threat of biological weapons. Crit. Rev. Microbiol. 24:157-168.[CrossRef][Medline]
6 - Backer, H. 2002. Water disinfection for international and wilderness travelers. Clin. Infect. Dis. 34:355-364.[CrossRef][Medline]
7 - Blazes, D. L., J. V. Lawler, and A. A. Lazarus. 2002. When biotoxins are tools of terror. Early recognition of intentional poisoning can attenuate effects. Postgrad. Med. 112:89-92, 95-96, 98.
8 - Burrows, W. D., and S. E. Renner. 1999. Biological warfare agents as threats to potable water. Environ. Health Perspect. 107:975-984.[Medline]
9 - Christopher, G. W., T. J. Cieslak, J. A. Pavlin, and E. M. Eitzen, Jr. 1997. Biological warfare. A historical perspective. JAMA 278:412-417.[Abstract/Free Full Text]
10 - Doellgast, G. J., G. A. Beard, J. D. Bottoms, T. Cheng, B. H. Roh, M. G. Roman, P. A. Hall, and M. X. Triscott. 1994. Enzyme-linked immunosorbent assay and enzyme-linked coagulation assay for detection of Clostridium botulinum neurotoxins A, B, and E and solution-phase complexes with dual-label antibodies. J. Clin. Microbiol. 32:105-111.[Abstract/Free Full Text]
11 - Doellgast, G. J., M. X. Triscott, G. A. Beard, J. D. Bottoms, T. Cheng, B. H. Roh, M. G. Roman, P. A. Hall, and J. E. Brown. 1993. Sensitive enzyme-linked immunosorbent assay for detection of Clostridium botulinum neurotoxins A, B, and E using signal amplification via enzyme-linked coagulation assay. J. Clin. Microbiol. 31:2402-2409.[Abstract/Free Full Text]
12 - Eisenberg, D., J. Soller, R. Sakaji, and A. Olivieri. 2001. A methodology to evaluate water and wastewater treatment plant reliability. Water Sci. Technol. 43:91-99.
13 - Gill, D. M. 1982. Bacterial toxins: a table of lethal amounts. Microbiol. Rev. 46:86-94.[Free Full Text]
14 - Gomez, H. F., R. Johnson, H. Guven, P. McKinney, S. Phillips, F. Judson, and J. Brent. 1995. Adsorption of BoNT to activated charcoal with a mouse bioassay. Ann. Emerg. Med. 25:818-822.[CrossRef][Medline]
15 - Grabow, W. O., C. G. Clay, W. Dhaliwal, M. A. Vrey, and E. E. Muller. 1999. Elimination of viruses, phages, bacteria and Cryptosporidium by a new generation Aquaguard point-of-use water treatment unit. Zentbl. Hyg. Umweltmed. 202:399-410.
16 - Hallis, B., B. A. James, and C. C. Shone. 1996. Development of novel assays for botulinum type A and B neurotoxins based on their endopeptidase activities. J. Clin. Microbiol. 34:1934-1938.[Abstract]
17 - Hoeger, S. J., D. R. Dietrich, and B. C. Hitzfeld. 2002. Effect of ozonation on the removal of cyanobacterial toxins during drinking water treatment. Environ. Health Perspect. 110:1127-1132.[Medline]
18 - Hörman, A., R. Rimhanen-Finne, L. Maunula, C.-H. von Bonsdorff, J. Rapala, K. Lahti, and M.-L. Hänninen. 2004. Evaluation of the purification capacity of nine portable, small-scale water purification devices. Water Sci. Technol. 50:179-183.
19 - Josko, D. 2004. Botulin toxin: a weapon in terrorism. Clin. Lab. Sci. 17:30-34.[Medline]
20 - Khan, A. S., D. L. Swerdlow, and D. D. Juranek. 2001. Precautions against biological and chemical terrorism directed at food and water supplies. Public Health Rep. 116:3-14.
21 - Lahti, K., J. Rapala, A. L. Kivimäki, J. Kukkonen, M. Niemelä, and K. Sivonen. 2001. Occurrence of microcystins in raw water sources and treated drinking water of Finnish waterworks. Water Sci. Technol. 43:225-228.
22 - Mobley, J. A. 1995. Biological warfare in the twentieth century: lessons from the past, challenges for the future. Mil. Med. 160:547-553.[Medline]
23 - Monjour, L., C. Volta, N. Uwechue, and G. de Lorenzi. 1990. Evaluation of traditional filters for water purification in Burkina Faso. Ann. Soc. Belg. Med. Trop. 70:311-315.[Medline]
24 - Nordic Committee on Food Analysis. 1991. Botulinum toxin. Determination in foods, blood, and other test materials. NMKL method no. 79, 2nd ed. Nordic Committee on Food Analysis, Oslo, Norway.
25 - Rapala, J., K. Lahti, L. A. Räsänen, A. L. Esala, S. I. Niemelä, and K. Sivonen. 2002. Endotoxins associated with cyanobacteria and their removal during drinking water treatment. Water Res. 36:2627-2635.[Medline]
26 - Raynor, T. H., E. L. White, J. M. Cheplen, J. M. Sherrill, and T. E. Hamm, Jr. 1984. An evaluation of a water purification system for use in animal facilities. Lab. Anim. 18:45-51.[Abstract/Free Full Text]
27 - Schechter, R., and S. S. Arnon. 2000. Extreme potency of BoNT. Lancet 355:237-238.
28 - Schlosser, O., C. Robert, C. Bourderioux, M. Rey, and M. R. de Roubin. 2001. Bacterial removal from inexpensive portable water treatment systems for travelers. J. Travel Med. 8:12-18.[Medline]
29 - Schmidt, W., H. Willmitzer, K. Bornmann, and J. Pietsch. 2002. Production of drinking water from raw water containing cyanobacteriapilot plant studies for assessing the risk of microcystin breakthrough. Environ. Toxicol. 17:375-385.[CrossRef][Medline]
30 - Army Medical Research Institute of Infectious Diseases. 2001. Botulinum. In AMRIIDs medical management of biological casualties handbook. [Online.] U.S. Army Medical Research Institute of Infectious Diseases, Fort Detrick, Md. http://www.vnh.org/BIOCASU/17.html.
31 - U.S. Food and Drug Administration. 2001. Bacteriological analytical manual online. U.S. Food and Drug Administration, Center for Food and Safety and Applied Nutrition, College Park, Md. [Online.] http://www.cfsan.fda.gov/
ebam/bam-toc.html.
32 - Wannemacher, R. W., R. E. Dinterman, W. L. Thompson, M. O. Schimdt, and W. D. Burrows. 1993. Treatment for removal of biotoxins from drinking water. Technical report 9120. U.S. Army Biomedical Research and Development Laboratory, Fort Detrick, Frederick, Md.
33 - Warhurst, A. M., S. L. Raggett, G. L. McConnachie, S. J. Pollard, V. Chipofya, and G. A. Codd. 1997. Adsorption of the cyanobacterial hepatotoxin microcystin-LR by a low-cost activated carbon from the seed husks of the pan-tropical tree, Moringa oleifera. Sci. Total Environ. 207:207-211.[CrossRef][Medline]
34 - Whitby, M., A. C. Street, T. A. Ruff, and F. Fenner. 2002. Biological agents as weapons 1: smallpox and botulism. Med. J. Aust. 176:431-433.[Medline]
35 - Wictome, M., K. Newton, K. Jameson, B. Hallis, P. Dunnigan, E. Mackay, S. Clarke, R. Taylor, J. Gaze, K. Foster, and C. Shone. 1999. Development of an in vitro bioassay for Clostridium botulinum type B neurotoxin in foods that is more sensitive than the mouse bioassay. Appl. Environ. Microbiol. 65:3787-3792.[Abstract/Free Full Text]
Applied and Environmental Microbiology, April 2005, p. 1941-1945, Vol. 71, No. 4
0099-2240/05/$08.00+0 doi:10.1128/AEM.71.4.1941-1945.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.
This article has been cited by other articles:
-
Lindstrom, M., Korkeala, H.
(2006). Laboratory Diagnostics of Botulism. Clin. Microbiol. Rev.
19: 298-314
[Abstract]
[Full Text]