Previous Article | Next Article ![]()
Applied and Environmental Microbiology, May 2005, p. 2250-2255, Vol. 71, No. 5
0099-2240/05/$08.00+0 doi:10.1128/AEM.71.5.2250-2255.2005
Copyright © 2005, American Society for Microbiology. All Rights Reserved.

Department of Environmental Health, Science, and Policy, University of California, Irvine, California 92697
Received 3 August 2004/ Accepted 7 December 2004
|
|
|---|
|
|
|---|
Among human viral pathogens, adenovirus is the only DNA virus in the enteric virus family, hence, the most thermostable virus, and can survive for prolonged periods in environmental waters (13, 16, 17). Adenovirus infections occur year-round, and there is little or no seasonal variation in shedding (1). Adenoviruses have been detected in raw sewage in relatively high frequencies (22, 25), and they were found in environmental sources, including Southern California coastal waters, using molecular methods (23, 33). Pina et al. (33) suggested that adenoviruses be used as an index of human viral pollution because of the concomitancy of adenovirus with other human viruses. There are presently 51 adenovirus serotypes which can be classified into six species, designated species A to F (9). Species F contains two fastidious enteric serotypes, 40 and 41, which are among the leading causes of childhood diarrhea. To prevent human exposure to viral pathogens through drinking water, the Environmental Protection Agency enacted the Information Collection Rule in 1996, which requires all water utilities that serve more than 100,000 households to monitor their source water for viruses. According to the Information Collection Rule, the total culturable viruses had to be detected and enumerated by the total-culturable-virus-assay-most-probable-number (TCVA-MPN) method (14). However, analysis of enteric viruses, particularly adenovirus serotypes 40 and 41, in surface water samples might be greatly underestimated by the TCVA-MPN method due to their fastidious characteristics (6). There have been many efforts attempting to increase the sensitivity of detection for adenovirus, and molecular approaches have emerged as the most promising methods.
PCR has become an important method for the rapid, sensitive, and specific detection for bacterial and viral agents in the past decade (for examples, see references 7, 30, and 34). More recently, real-time PCR was also applied to quantify the presence of microorganisms in the complex environmental matrices. This method improves the accuracy and sensitivity of traditional PCR by adding a fluorescently labeled probe so that the target gene can be detected and quantified without subsequent verification. Among the various quantitative PCR strategies available, those based on real-time monitoring of the amplification reaction are the most accurate (24). A real-time PCR method targeting 16S rDNA was developed to detect E. faecalis in water samples (35). The dynamic range for cell detection spanned 5 logs, and the detection limit was determined to be 6 CFU/reaction without nucleic acid extraction, indicating that real-time PCR is very robust and sensitive in quantification of enterococcus in environmental samples (35). More recently, real-time PCR was applied to detect and quantify Escherichia coli (E. coli) O157:H7 (21) in food samples and Enterococcus spp. in drinking water (15) and to monitor nitrifying bacteria in a municipal wastewater treatment plant (19). Gu et al. (18) also reported real-time PCR quantification of adenovirus in a patient's stool samples. By using control viral samples, sensitivity of detection was demonstrated to be fewer than 10 copies of viral genome per reaction and quantitative linearity was demonstrated to be from 10 to 106 copies of input viral DNA (18).
Human waste contamination of the environment is currently being monitored only with bacterial indicators. However, bacterial and viral contaminations are not necessarily associated and linked with each other (27). Therefore, the fate of various microorganisms through wastewater discharge needs to be further addressed because of the discrepancy between the fates of viruses and bacteria (37). Few methods have been published, particularly with respect to rapid viral quantification, and therefore it is appealing to investigate the presence of human viruses and bacterial indicators using the same approach for common environmental samples, such as sewage, coastal waters, and river waters, to illuminate the relationship between bacterial indicators and human viruses. We selected adenoviruses and enterococci as the target of detection because of their usefulness as an index of coastal pollution. In the present report, we describe the development of real-time PCR methods for quantification of both human adenoviruses and enterococci in environmental samples.
|
|
|---|
Adenovirus serotype 40 (ad-40), used in real-time PCR optimization and sensitivity assay, was isolated from an environmental sample of Newport Bay, California, by cell culture (HEK-293A, detailed below) in our laboratory and confirmed by sequencing of a 482-bp region in the hexon gene (data not shown). The adenovirus isolate was propagated in HEK-293 cells and purified by a freezing and thawing method. The purified ad-40 particles were titrated using plaque assay on the HEK-293A cells.
The human embryonic kidney cell line (HEK-293A) was obtained from the University of Southern California (courtesy of Michael Lai) at passage 34 and was used in this study between passage 42 and 50. The cells were grown at 37°C in Dulbecco's modified Eagle's medium with glucose and L-glutamine and supplemented with 5% fetal bovine serum (FBS), 100 U/ml penicillin, and 100 µg/ml streptomycin. Human lung carcinoma cell line A549 was obtained from Los Angeles Sanitation District (courtesy of Shawn Thompson) at passage 108 and was used in this study between passage 115 and 123. A549 cells were grown in Ham's F12 medium also containing 5% FBS, 2 mM L-glutamine, 100 U/ml penicillin, and 100 µg/ml streptomycin. Cells were subcultured at 4- to 5-day intervals with a trypsin-EDTA solution (Cellgro). Both cell lines were used to titrate the viable human adenoviruses in sewage samples by plaque assay.
Adenovirus plaque assay in sewage.
Sewage samples (10 ml) were ultracentrifuged at 207,570 x g for 90 min. Pellets were resuspended in 500 µl phosphate-buffered saline (PBS) (pH 7.4) and extracted with 1 volume of chloroform twice to remove cytotoxicants. The supernatants were further clarified by filtering through 0.2-µm-pore-size filters (PES [4 mm, low protein binding]; Whatman). An equal portion of each purified sample was inoculated onto confluent HEK-293A and A549 cells in 6-well plates. The plates were incubated in a CO2 incubator at 37°C for 1 h and were rocked every 15 min for viral adsorption. Then, inoculated cells were carefully washed once with prewarmed PBS (pH 7.4) and overlaid with warm Dulbecco's modified Eagle's medium, 5% FBS, and 1.25% agarose containing 50 µg/ml gentamicin and 0.25 µg/ml amphotericin B. Cells were incubated at 37°C with 5% CO2. A second overlay was applied at 6 to 7 days postinfection. Inoculated cell cultures were examined microscopically daily up to 2 weeks postinfection. Plaques were counted as PFU/100 ml sample at 10 days. Highly diluted recombinant adenovirus serotype 5 was used on HEK-293 cells as a positive control, while PBS was used as a negative control. The recombinant adenovirus expresses green firefly protein in infected cells; hereby, the resultant plaque can be confirmed and differentiated under UV microscopy.
Environmental samples.
Sewage samples were collected by random sampling in two Southern California sewage treatment plants. Primary effluent was raw domestic sewage after sedimentation. Secondary effluent was treated by activated sludge. Some of the secondary effluents were also treated with chlorine at various locations in the effluent transportation pipeline. The final concentration of chlorine residue was between 2 and 3 ppm in the composite samples.
Coastal water samples were collected from a small estuary, Newport Bay, California, and its tributary, San Diego Creek. The salinity of the water samples was 1 ppt (parts per thousand) in the San Diego Creek site, approximately 15 ppt in mid-Newport Bay, and nearly 30 ppt in lower Newport Bay where the bay water was well mixed with the ocean water. In addition, 31 water samples were collected from various locations and depths from Newport Dunes, a designated recreational beach and recreational vehicle park, in the middle of Newport Bay.
Quantification standards for real-time PCR.
To create adenovirus real-time PCR standards, ad-40 hexon gene was amplified by a pair of degenerate primers: Ad1 (5'-TTC CCC ATG GCI AYA ACA C-3') and Ad2 (5'-CCC TGG TAK CCR ATR TTG TA-3') (39). The resultant 482-bp amplicon was cloned into the pCR2.1-TOPO vector (Invitrogen Inc.) and confirmed by sequencing. The purified recombinant plasmid DNA was quantified by UV spectrophotometer and then serially diluted in double-distilled water (ddH2O) to a final concentration ranging from 2.5 x 103 to 2.5 x 108 copies of genome equivalent/ml. Four-microliter aliquots of each dilution (10 to 106 genome equivalent/reaction) were used for real-time PCR in triplicates to create the standard curve and used as quantification standards for adenovirus in experimental samples. A new standard curve was run for each real-time PCR.
To generate standards for enterococcus, whole bacterial genomic DNA of E. faecalis was extracted using a QIAamp DNA mini kit (QIAGEN Inc.) and quantified by UV spectrophotometer. The concentration of bacterial genomic DNA was converted to a genome equivalent and serially diluted to a range of 2 x 103 to 2 x 109 copies/ml. A volume of 2.5 µl of each dilution (5 to 5 x 106 copies/reaction) was used in triplicates as a quantitative standard for enterococcus.
Sample preparation for real-time PCR.
For real-time PCR of enterococcus, 1 to 10 ml of E. faecalis cultures or environmental samples was centrifuged at 6,654 x g for 5 min, and the resultant bacterial pellet was resuspended in 100 µl of lysis buffer (10 mM Tris-HCl [pH 8.3], 100 mM NaCl, 1 mM EDTA, 1% [vol/vol] Tween 20) and 10 µl of 10 mg/ml of proteinase K and incubated at 45°C for 3 h. For coastal water samples, the lysates were extracted with 100 µl phenol-chloroform-isoamyl-alcohol (24:25:1, pH 8.0) and the supernatant was precipitated with ethanol. The resultant DNA pellet was washed with 70% ethanol and dissolved in 30 µl ddH2O. For sewage samples, the upper liquid phase from phenol-chloroform-isoamyl-alcohol extraction was further purified using a QIAamp DNA Mini kit (QIAGEN) according to the manufacturer's instructions to remove PCR inhibitors and interferences. Purified bacterial DNA was eluted with 30 µl ddH2O.
For real-time PCR of adenoviruses, 10-ml sewage samples were ultracentrifuged at 207,750 x g for 90 min. Pellets were resuspended in 500 µl supernatant and extracted using equal volumes of chloroform twice. Viral nucleic acid was extracted from the concentrates using a QIAamp viral RNA Mini kit (QIAGEN) following the manufacturer's instruction and finally eluted in 30 µl ddH2O.
Real-time PCR.
Adenovirus primers were designed from the hexon gene encoding the viral structural protein. The oligonucleotide sequences were selected using the Primer Express program (ABI Biosystem Inc.) and manually examined for desired size and melting temperature (Tm) values. The primers and probe sequences were compared to gene sequences in NCBI GenBank using BLAST network service (2). To achieve coverage of a broad range of adenovirus serotypes, the primers and probe were degenerate. Sequences of the oligonucleotides and detectable serotypes are shown in Table 1. Real-time PCR for direct quantification of enterococcus was developed based upon the previous report of Frahm and Obst (15). The enterococcus primers and Taqman probe target the 23S rRNA gene (Table 1).
|
View this table: [in a new window] |
TABLE 1. Summary of primers and probes for detection of enterococcus and adenovirus
|
|
|
|---|
Figure 1 shows the plot of real-time PCR amplification of E. faecalis using known copies of genomic equivalent as a standard and a serially diluted bacterial culture as a sensitivity calibrator. The results showed a positive log linear correlation of E. faecalis genome copy number and PCR threshold cycle number, stretching a 7-log unit, between 5 and 5 x106/reaction. The correlation coefficient of the standard curve was constantly 0.99, while the slope was 3.3. The sensitivity of detection for serially diluted known numbers of E. faecalis suspension counted by culture was comparable to the standard curve. The lower limit of detection was near 5 CFU/reaction (Fig. 1). Compared to the standard curve, however, a lower slope of the diluted bacteria was noted at the lower concentration range (5 to 50 CFU/reaction). This discrepancy is likely due to the loss of template during DNA preparation from the diluted bacterial samples.
![]() View larger version (32K): [in a new window] |
FIG. 1. Standard curve and sensitivity of real-time PCR for detection of enterococcus. Genomic DNA ( ) extracted directly from Enterococcus faecalis was used as the standard; serially diluted Enterococcus faecalis culture ( ) was used as the sensitivity calibrator. Each data point represents the threshold cycle (Ct) average of samples prepared in triplicate. The solid line represents the standard curve, and the dashed line represents the sensitivity curve.
|
![]() View larger version (32K): [in a new window] |
FIG. 2. Standard curve and sensitivity of real-time PCR detection of adenovirus. Plasmid inserted with a fragment of adenovirus hexon gene ( ) was used as the standard; serially diluted adenovirus serotype 40 ( ) with known titers was used as the sensitivity calibrator. Each data point represents the cycle threshold (Ct) average of samples prepared in triplicate. The solid line represents the standard curve, and the dashed line represents the sensitivity curve.
|
|
View this table: [in a new window] |
TABLE 2. Comparison of enterococcus quantifications by real-time PCR and culture assay in environmental waters
|
Application of real-time PCR for quantification of adenoviruses in environmental waters.
Real-time PCR was applied to quantify adenoviruses in sewage samples in comparison with a plaque assay on A549 and HEK-293A cell lines. Typical viral plaques with diverse morphology were observed on HEK-293A cells but not on A549 cells, indicating that the HEK-293A cell line is more sensitive to infection of adenovirus than A549. Interestingly, number of infectious adenoviruses decreased from 67 or 80 PFU/100 ml in the primary sewage effluents to below detection in the secondary effluents in samples collected from both treatment plants (Table 3). However, there was virtually no difference in viral load between primary effluents and secondary effluents detected by real-time PCR (Table 3). The average number of adenoviral genomes detected in sewage by real-time PCR was 8.1 x 104 viral genomic copies/100 ml, which is comparable to the genomic copies of poliovirus in sewage reported by Tsai and Parker (38).
|
View this table: [in a new window] |
TABLE 3. Comparison of adenovirus quantification by real-time PCR and plaque assay in sewage samples
|
|
|
|---|
We chose E. faecalis whole genomic DNA instead of plasmid DNA with a single insert of target sequence as a quantification standard, because there are multiple copies of the 23S rRNA gene in each enterococcus genome. Using recombinant plasmid DNA as a standard may compromise the quantification of real-time PCR for enterococcus. The primers and probe for enterococcus real-time PCR used in this study were originally described by Frahm and Obst (15); however, this method was not applied quantitatively to environmental samples in the previous report. A culture enrichment step was required to increase the target bacterial concentration before it was detectable by real-time PCR. The enrichment itself tarnished the characteristic of real-time quantification. In this study, we optimized the ratio of primers to probes from the previously reported 200 nM (forward primer), 300 nM (reverse primer), and 360 nM (probe) to 900 nM, 300 nM, and 250 nM, respectively, to achieve an approximately twofold increase in signal intensity (data not shown). We also improved the extraction and purification method to achieve optimal bacterial DNA purification and removal of PCR inhibitors from water samples. These improvements have allowed this method to be used in environmental samples for quantification of enterococcus in less than 4 h. Compared to the other real-time PCR method reported for E. faecalis (35), our current method detects a broader range by targeting the genus rather than an individual species. Therefore, our results are more comparable to those of the culture assay for environmental samples.
The discrepancy between the real-time PCR quantification and enterococcus culture counts was observed in the chlorinated sewage effluents and coastal waters. This is not surprising, because it is well known that chlorination and physical stress may "injure" the cell but may not completely destroy the bacterial genome. In addition, the VBNC state may also account for the discrepancy. VBNC is a survival mechanism of bacteria facing environmental stress conditions (8). Bacteria are no longer able to grow and form colonies on conventional culture media but demonstrate metabolic activity, maintain their pathogenicity, and, in some cases, may return to active growth when optimal conditions are restored (31). Recently, E. faecalis has been demonstrated to be able to enter the VBNC state (26). Moreover, a reverse transcription-PCR assay has been established to detect E. faecalis pbp5 mRNA to monitor the viability of VBNC (10). VBNC lends further support to criticisms of the traditional methods used to evaluate water quality on the basis of plate counts.
Theoretically, the combination of adenovirus primers and probe covers 14 different serotypes of human adenoviruses. The only nonhuman viral target is simian adenovirus due to the high degree of hexon gene homology between simian adenovirus 25 and other human adenoviruses. Since simian adenoviruses are not expected to be a contamination problem in the urban region of the United States, the application of this method will be unlikely to cause misinterpretation of results of human adenovirus contamination.
In comparison with the plaque assay results obtained using HEK-293A, real-time PCR methods yielded viral counts 3 to 4 orders of magnitude higher. This is similar to a previous study which showed that a much higher number of positive results was obtained by nested PCR than by a cell culture assay (34). The relationship between the copy number of viral genomes and PFU is inconsistent and could be affected by many factors, such as virus strains, the cell line used, sample preparation, and culture conditions. Tsai and Parker (38) obtained 6 x 105 poliovirus for 1 PFU, which is similar to the ratio reported by Metcalf et al. (28). It should be noted that the ratio of viral particles to PFU was not defined for environmental samples in this study. However, the copy number of viral genomes should be proximal to PFU in the calibrators, because purified viral particles from cell culture were used. Therefore, it is important to emphasize that the health implication of detecting viral genome by PCR has multiple complications. It is likely that molecular analysis-based methods tend to overestimate the quantity of infectious human viruses, while the tissue culture-based methods tend to underestimate them. The development of rapid and sensitive genome-based diagnostic tools will improve our ability to illuminate the relationship between viral infectivity and genomic quantity. The method presented here demonstrates that real-time PCR is capable of rapidly quantifying the adenoviral load in environmental waters.
This is the first study that demonstrated the application of degenerate primers and probe for real-time quantification of human adenoviruses in environmental waters. Prospective improvements in DNA extraction and purification are likely to increase the accuracy and sensitivity of these quantification methods and allow a real-world evaluation of efficiency for removing human viral and bacterial pathogens in sewage treatment plants. Real-time PCR will provide a rapid tool to monitor human pathogens in environmental waters.
We thank Yu-Li Tsai from Orange County Sanitation District for providing sewage samples and technical consultants. We also thank Weiping Chu for technical support in the lab, Xiaojie Ding and Mandy Han for assisting with cell culture assays, and Ryan Reeves for assisting with environmental water sample collection.
Present address: Beckman Coulter, Inc., Chaska, MN 55318. ![]()
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»