National Institute for Public Health and the Environment (RIVM), Microbiological Laboratory for Health Protection (MGB), Health-Related Water Microbiology, Antonie van Leeuwenhoeklaan 9, 3720 BA Bilthoven, The Netherlands
Received 9 September 2004/ Accepted 10 February 2005
| ABSTRACT |
|---|
|
|
|---|
| INTRODUCTION |
|---|
|
|
|---|
In water, viruses are usually present in low numbers. To be able to detect these low numbers, several hundred liters of surface water need to be analyzed. A variety of concentration methods is available, many of them consisting of two successive steps. Frequently used methods to concentrate water samples are either electronegative or electropositive membrane filtration or filtration using glass powder or glass wool. A second concentration step can be performed by ultrafiltration (UF) or organic flocculation. Viruses remain infectious in the resulting concentrates but are less suitable to isolate viral RNA. Despite repeated efforts to improve RNA isolation from water samples, no standard method is available (5, 15, 23). Two-phase separation using Dextran T40 and PEG 6000 is a commonly used method to isolate RNA (3, 16, 23, 27) but is, however, not suitable to detect culturable viruses. A more detailed overview of these methods has been described by Wyn-Jones and Sellwood (32).
Enterovirus concentrations in surface waters are often determined by cell culture using Buffalo green monkey (BGM) cells. These cells are widely used in monolayer plaque assays for the routine detection of infectious enteroviruses in water (8). Unfortunately, not all enterovirus types are detected in BGM cells, especially the pathogenic coxsackievirus types A (26), which are difficult to detect; only coxsackievirus A7, A9, and A16 can infect and multiply in BGM cells, whereas other coxsackie A viruses (A1 through A6, A8, A10 through A15, A17 through A22, and A24) are not detected (8). Furthermore, cell culture is an expensive and time-consuming method, implicating the need for the detection of viruses by molecular methods such as conventional reverse transcription (RT)-PCR (11, 29) or nucleic acid sequence-based amplification (NASBA), which isothermally amplifies RNA (6). NASBA detection of viral RNA in water has been described for hepatitis A virus in artificially contaminated sewage water (7, 18). Although mainly described as end point assays, amplification products of both techniques can be detected by real-time methods (14). The major advantage of real-time detection is the ability to quantify amplification products, which is very important to be able to estimate the public health risks of low levels of enteric viruses in surface water. Furthermore, detection and hands-on time are decreased enormously. Real-time RT-PCR is frequently used for detection of enterovirus in clinical samples (19, 25, 28) but has less frequently been described for environmental samples (9). An enterovirus NASBA using end point detection has been described for clinical samples (10, 13, 21). At present, a real-time commercial enterovirus NASBA assay is available.
The aim of this study was to develop a rapid, standardized method for the detection of enteroviruses in large-volume surface water samples. We used a concentration method which was appropriate for the detection of infectious viruses as well as for the detection of viral RNA. We compared three different RNA extraction protocols and found the best results with a new isolation method using magnetic silica beads. Furthermore, we compared enterovirus detection by an in-house RT-PCR with a novel commercially available real-time NASBA assay. These molecular data were compared with the numbers of infectious enterovirus particles detected by cell culture.
| MATERIALS AND METHODS |
|---|
|
|
|---|
Sampling and concentration by UF.
Ten liters of raw and treated sewage water and large volumes of river water (approximately 600 liters) were collected and concentrated by a conventional filter adsorption-elution method (30). Magnesium chloride was added to the water sample to a final concentration of 0.05 M to enable the formation of a virus-magnesium complex. By reducing the pH to 3.8 with 0.5 M HCl, these complexes adsorb to a negatively charged cartridge filter (1.2 µm nominal; Millipore, Etten-Leur, The Netherlands). Viruses were eluted from the filter with elution buffer (pH 9.0) containing 3% beef extract (Difco Laboratories, Detroit, MI) and 0.05 M Tris (Bisolve, Valkenswaard, The Netherlands). The typical eluate volume of 10 liters of raw sewage water is approximately 650 ml and approximately 1,800 ml for volumes of 600 liters of water. The eluate was neutralized with a concentrated acetic acid buffer (pH 5.0), resulting in a final eluate with a pH of approximately 7.4. Two-thirds of the eluates were further concentrated to approximately 40 ml by UF using a cellulose-acetate filter (nominal molecular weight limit, 10,000) under high pressure (three bars). The ultrafilter was rinsed with 3% beef extract (pH 9.0). This final UF concentrate was stored at 70°C until further use. The remaining one-third of the eluates was concentrated by two-phase separation as described previously (23).
Detection of enterovirus by monolayer plaque assay.
Infectious viruses were detected by use of a monolayer plaque assay (22). UF concentrate was quickly thawed at 37°C. Antibiotics (final concentrations of penicillin G at 576 µg/ml, streptomycin sulfate at 4,476 U/ml, Amphotericin B at 72 µg/ml, kanamycin monosulphate at 2.9 mg/ml, and neomycin at 576 µg/ml) were added to inactivate bacteria in the concentrate. The suspension was incubated for 1 h at room temperature, after which it was inoculated onto BGM kidney cells. BGM cells were grown to confluent monolayers in 75-cm2 plastic flasks. Before inoculation, culture medium was removed and the sample was added to the flasks. The cultures were incubated at room temperature for 2 h to allow virus adsorption to the cells. The cells were overlaid with medium 199 supplemented with Earle's salts (Life Technologies, Breda, The Netherlands) and 10% fetal bovine serum (Life Technologies), 0.9% Bacto Agar (Difco, Amsterdam, The Netherlands), 0.2% bicarbonate, 100 IU penicillin, and 100 µg/ml streptomycin (Life Technologies). After 9 days of incubation in an inverted position at 37°C, the cells were stained with 0.03% neutral red (Sigma-Aldrich, Zwijndrecht, The Netherlands) in 0.9% agar and incubated for 4 to 6 h at 37°C in the dark. After 24 h, visible plaques were counted and the virus concentration in the original water sample was calculated from the analyzed volume and the virus count.
Two-phase separation (2PHS) and RNA isolation (method I).
Prior to the isolation of viral RNA, the eluate of the conventional filter adsorption-elution method was further concentrated by a modified protocol of a two-phase separation method (27) described by Lodder et al. (23). Briefly, 650 ml eluate, 1% (wt/vol) dextran T40 (Pharmacia, Roosendaal, The Netherlands), 10% (wt/vol) PEG 6000 (Merck, Amsterdam, The Netherlands), 0.2 M NaCl, and 10 mM phosphate buffer (pH 7.2) were mixed for 1 h at 4°C. The suspension was then transferred to a separation funnel and left overnight at 4°C. After separation, the bottom phase and the interphase were harvested. Further purification was done by spin-column chromatography using Sephadex G200 (ICN, Zoetermeer, The Netherlands) and by ultrafiltration in a Centricon 100 microconcentrator with a 100,000-molecular-weight cutoff (Amicon, Dronten, The Netherlands). The average retentate volumes of 1 to 5 ml were subjected to RNA extraction using guanidinium (iso)thiocyanate (GITC)-silica according to the method of Boom et al. (4).
RNA isolation from UF concentrate using NucliSens isolation reagents (method II).
For NucliSens-based RNA isolation, 12.5 µl to 6 ml UF concentrate was used. At least two volumes of NucliSens lysis buffer (bioMérieux, Boxtel, The Netherlands) was added, followed by incubation for 10 min at room temperature. Thereafter, 4,000 copies of internal control (IC) RNA, supplied with the NucliSens EasyQ enterovirus assay, were added. IC RNA consists of RNA derived from a cloned poliovirus 5' untranslated region in which a segment of 24 bp was replaced by a fragment of 20 bp from the genome of potato leafroll virus. Either 50 µl of NucliSens nonmagnetic or 50 µl of NucliSens magnetic silica particle suspension (bioMérieux, Boxtel, The Netherlands) was added, followed by 10 min of incubation at room temperature to allow nucleic acid binding. Silica particles were extensively washed with different wash buffers according to the instructions of the manufacturer. The NucliSens miniMAG instrument (bioMérieux, Boxtel, The Netherlands) was used to collect and wash the magnetic silica particles. Nucleic acids were recovered from the particles during a 5-min incubation period at 60°C, using 50 µl elution buffer.
Enterovirus RT-PCR.
The highly conserved 5' untranslated region of enteroviruses was used as the target for amplification. The RT-PCR was performed as described earlier (29). The specificity of the detected enteroviruses was confirmed by the hybridization of RT-PCR products as described previously.
Enterovirus NASBA.
Enteroviruses were detected using the NucliSens Basic kit and the NucliSens EasyQ enterovirus reagents (bioMérieux, Boxtel, The Netherlands) mainly as described by Landry et al. (21) with modifications for real-time detection of the amplification products. A sequence-specific enterovirus molecular beacon was used for the detection of wild-type enterovirus, whereas the IC molecular beacon was used to detect an enterovirus-specific internal control RNA. The entero-beacon contains a 6-carboxyfluorescein (FAM) fluorophore at the 5' end, whereas the IC beacon contains a carboxyrhodamine fluorophore. The NucliSens EasyQ analyzer was used for the real-time detection of NASBA amplicons (bioMérieux, Boxtel, The Netherlands).
Estimation of enterovirus concentrations in water.
Estimation of the numbers of viral genomes present in water by RT-PCR (PCR-detectable units [PDU]) and NASBA (NASBA-detectable units [NDU]) was performed on 10-fold serially diluted RNA samples (end point dilution). Virus concentrations in the undiluted samples were estimated as the most probable numbers by the use of the presence or absence of virus genomes in the 10-fold RNA dilutions on replicate samples under the assumption that negative samples do not contain viral RNA. Application of the Poisson distribution was justified by the assumption that the infectious virus particles or viral RNA was dispersed randomly in the sample. The maximum-likelihood method was used to estimate the number of virus particles in the undiluted sample (24). A negative binominal model gives the best fit for the distribution of virus particles in the original and diluted samples. The 95% confidence interval was estimated for each virus concentration.
| RESULTS |
|---|
|
|
|---|
|
Thus, UF concentrates commonly used to detect enterovirus by cell culture are applicable to detect RNA as well. Isolation with the NucliSens magnetic extraction reagents resulted in the most efficient detection of enterovirus RNA.
Extraction efficiency of RNA isolation with the miniMAG system.
To assess the efficiency of RNA isolation by magnetic silica beads, three large-volume water samples (02-8, 01-6, 00-1) from different rivers in The Netherlands were UF concentrated. Enterovirus concentrations as determined by cell culture were 1.4, 0.65, and 14.9 PFU/liter, respectively. Different volumes of UF concentrates were analyzed, ranging from 12.5 µl to 6 ml. Four thousand copies of an enterovirus-specific IC RNA were added, which were coamplified with the viral RNA using the same set of primers. The presence of wild-type and IC RNA was analyzed by real-time NASBA. Amplification products were detected by hybridization using two different molecular beacon probes, one specific for the wild-type enterovirus and the other specific for the IC product. IC RNA was not detected when RNA was extracted from concentrate volumes of greater than 200 µl (data not shown), indicating that the use of larger volumes results in either a less efficient RNA extraction or the presence of inhibitors. Thus, for these samples that contain a large amount of background nucleic acids (3% beef extract), we recommend that RNA be isolated with magnetic silica beads from samples of 200 µl or less. Analysis of larger volumes will consequently underestimate the virus titer.
Comparison of two RNA isolation methods.
The conventional RNA isolation following two-phase separation, spin column gel chromatography, and ultrafiltration (method I: 2PHS plus Boom) (23) was compared with RNA isolation by using the NucliSens magnetic extraction kit following UF concentration (method II: UF plus magnetic extraction) with respect to extraction efficiencies and the presence of inhibitors. To this end, five large-volume water samples of rivers A and B were concentrated by filtration on a negatively charged membrane and further processed to isolate RNA by method I and method II. As depicted in Table 1, the input volumes of water used for RNA isolation (extracted volume) largely differed between the two extraction methods. To compare the two RNA isolation methods, 10-fold dilutions of the five RNA samples were analyzed by RT-PCR for the presence of enterovirus RNA in triplicate. Despite the analyses of relatively small volumes with method II, in four out of five samples, enterovirus RNA was detected (02-8, 02-9, 04-1, and 04-2); in these four samples, undiluted RNAs were positive as well as three of the 10-times-diluted RNA samples (02-8, 04-1, and 04-2) (Table 1). By using method I, two out of five samples (02-8 and 02-9) gave positive results. Enterovirus RNA was detected in none of the undiluted samples, suggesting that PCR inhibitors were present. Moreover, method I appeared to be less sensitive because the analysis of 103-diluted RNA samples, corresponding to volumes varying between 7.61 ml and 14.0 ml, were all negative. In four out of five undiluted samples of method II, enteroviruses were detected, corresponding to volumes ranging from 6.98 ml to 31.9 ml of water sample.
|
|
Comparison of RT-PCR and real-time NASBA.
Detection of enterovirus RNA by RT-PCR was compared with real-time NASBA. To this end, NucliSens magnetic extraction was used to isolate the RNA of 10 additional water samples from rivers A, C, and D and the presence of enterovirus RNA was determined by our in-house RT-PCR assay. The presence of enterovirus RNA in all samples was analyzed by the real-time enterovirus NASBA assay as well, using the same amount of input RNA. Virus concentrations were estimated semiquantitatively on 10-fold serially diluted RNA samples by both molecular methods and were compared with virus titers as determined by the BGM monolayer plaque assay. Table 2 shows that 12 out of 15 samples (80%) were positive by RT-PCR; two out of three (13%) negatives (03-2, 01-5, and 04-4) were also negative by cell culture (03-2 and 04-4). Nine of the 15 samples (60%) were positive when detected by NASBA. Three of the six negative samples were also negative by RT-PCR (03-2, 01-5, and 04-4). The other three samples (04-1, 03-3, and 04-3) contained 0.26, 0.12, and 0.56 PFU/liter culturable enteroviruses, respectively, suggesting that our in-house RT-PCR assay might be slightly more sensitive than NASBA. On the other hand, in four samples (02-8, 01-3, 01-6, and 01-7), the detected virus concentrations by NASBA were at least five times higher than the concentrations detected by RT-PCR, suggesting the opposite. In one sample (04-1), a high quantitation was obtained with RT-PCR (1,317 PDU/liter) whereas no enterovirus RNA was detected by NASBA. Average enterovirus concentrations in the 15 analyzed surface waters as determined by cell culture were 0.49 PFU/liter, whereas estimated concentrations determined by RT-PCR and NASBA were 342 PDU/liter and 841 NDU/liter, respectively.
In enterovirus-containing surface waters with virus concentrations lower than 0.6 PFU/liter, enteroviruses were not always detected by molecular methods whereas they were by cell culture. This indicates that the cell culture detection limit is lower than that of the molecular methods. Enterovirus concentrations lower than 0.6 PFU/liter are detected more consistently by RT-PCR than by NASBA.
| DISCUSSION |
|---|
|
|
|---|
Enteroviruses in surface waters are mainly determined by cell culture, using a BGM monolayer plaque assay (8). This very sensitive, quantitative method, however, is unable to detect certain enterovirus types, especially many of the coxsackie A virus types (8). These enteroviruses can be detected by molecular methods if general primers are used for amplification. We compared two different molecular detection methods, an in-house RT-PCR versus a commercial real-time NASBA assay. Detection of viruses in water by RT-PCR has been described before (11, 29), whereas detection by NASBA has been described only for hepatitis A virus in artificially contaminated sewage water (18). NASBA has several potential advantages over RT-PCR, including the fact that NASBA was developed specifically for RNA target amplification, making it suitable for the detection of viruses in water, which are mainly RNA viruses. In addition, real-time NASBA is a one-step closed amplification process, which makes it less prone to cross-contamination and reduces the hands-on time. According to Heim and Schumann, a one-step enterovirus NASBA achieved about the same sensitivity as a three-step nested-RT-PCR (13). Taking these possible advantages of NASBA into consideration, we compared the detection of enteroviruses in water by RT-PCR with NASBA. In the highly conserved 5' untranslated region, a fragment of 229 nucleotides is amplified by NASBA (21) and a fragment of 196 nucleotides by RT-PCR (29). As shown in Table 2, only 1 of the 15 samples that were positive by cell culture was negative by RT-PCR. On the other hand, NASBA analysis of the same RNA samples resulted in four negative results that were positive by cell culture. These data suggest that our in-house RT-PCR assay is slightly more sensitive than NASBA. In four samples, however, virus concentrations determined by NASBA were at least five times higher than concentrations that were found by RT-PCR, suggesting the opposite. These discrepancies in detection between NASBA and RT-PCR can be caused by the differences in methods, but also the use of different primers and probes might cause the differences in detection. This is argued, however, by sequence alignments of RT-PCR and NASBA primer and probes with enterovirus sequences, which give almost identical results with regard to the enterovirus types that can be detected. Typing of enteroviruses in the NASBA-negative samples might answer the question of whether the concentration of enterovirus RNA is too low to detect or whether enterovirus types which cannot be detected are present. In addition, the commercial real-time NASBA assay contains a homologous internal control RNA competing for the same primers as the wild-type RNA, potentially affecting sensitivity, whereas our in-house RT-PCR assay has no internal control.
Although enterovirus detection by real-time NASBA might not be as sensitive as RT-PCR, it does have several advantages. NASBA analysis is performed with the NucliSens Basic kit and NucliSens EasyQ Enterovirus reagents, which are commercial kits ensuring a constant quality. The RT-PCR is an in-house method and thus is less standardized, which consequently might give more variable results. Another major advantage is the availability of an internal control RNA, which will distinguish a truly negative result from a false-negative result because of the presence of inhibitors. In our false-negative samples, internal control RNA signals were present, indicating that samples were not negative because of the presence of inhibitors but because of the sensitivity of the assay. Furthermore, hands-on time is decreased because no separate RT step or labor-intensive Southern blotting is needed. In addition, total turnaround times from amplification to result for the RT-PCR and NASBA assays differ dramatically. Our in-house RT-PCR assay typically takes 12 h, resulting in a 2-day procedure, while the commercial real-time NASBA assay takes only 4 h.
To be able to compare the quantitative aspects of RT-PCR and NASBA to those of cell culture, virus concentrations (PCR- or NASBA-detectable units) were estimated as most probable numbers using the presence or absence of virus RNA in 10-fold RNA dilutions. As shown in Table 2, RNA isolation using magnetic silica beads highly increases the detectable amounts of PCR-detectable units. Thus, although estimated virus concentrations might be higher because viral genomes are detected and not infectious viruses, the RNA extraction method also appears to be critical for virus estimation. Our data clearly demonstrated that virus concentrations as determined by 2PHS concentration and RT-PCR underestimate the concentrations at least 100 times, which consequently will effect assessments of the public health risk, like the evaluations of environmental exposure to pathogenic microorganisms and drinking water treatment criteria. Although only infectious viruses have potential public health effects, additional information obtained by RT-PCR on the presence of nonculturable enteroviruses might be beneficial to the estimation of these health risks.
Further improvements in estimations of virus concentrations can be accomplished by quantitative detection. This has been described for enterovirus in seawater by real-time RT-PCR using an external standard of serially diluted poliovirus RNA (9). The main disadvantage, however, of an external standard is the lack of an internal control safeguarding proper nucleic acid isolation and amplification as well as checking for possible inhibitors of the reaction. We experienced high variation in amplification efficiencies between different sample locations and between different sampling dates at one location. The internal control RNA can be used as an internal calibrator, as has been described for the quantitation of HIV RNA by NASBA in clinical samples (31). The internal calibrator is coisolated and coamplified with the endogenous viral nucleic acids. Both amplification products can be detected simultaneously using specific molecular beacons with specific fluorophores. Quantitation is based on the assessment of the relative RNA growth rates during the transcriptional phase of amplification (31). This would be an ideal approach to quantitate viruses in environmental samples.
| ACKNOWLEDGMENTS |
|---|
We gratefully acknowledge Peter Teunis from the Computerization and Methodological Consultancy Unit for statistical analyses. We also thank bioMérieux for technical assistance and support.
| FOOTNOTES |
|---|
| REFERENCES |
|---|
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| J. Bacteriol. | Microbiol. Mol. Biol. Rev. | Eukaryot. Cell | All ASM Journals |
|---|