Previous Article | Next Article ![]()
Applied and Environmental Microbiology, July 2005, p. 3935-3941, Vol. 71, No. 7
0099-2240/05/$08.00+0 doi:10.1128/AEM.71.7.3935-3941.2005
U.S. Food and Drug Administration, Center for Food Safety and Applied Nutrition, College Park, Maryland 20740,1 Biological Defense Research Directorate, Naval Medical Research Center, Silver Spring, Maryland 20910,2 National Center for Food Safety and Technology, Summit-Argo, Illinois 605013
Received 20 April 2004/ Accepted 8 February 2005
|
|
|---|
|
|
|---|
A number of in vitro immunoassays with sensitivities comparable to that of the mouse bioassay have been described for BoNTs (13, 14, 15, 27, 28). An enzyme-linked coagulation assay was reported to have a sensitivity comparable to that of the mouse bioassay (13). In this assay, a complex consisting of toxin bound to chicken antibody (or biotinylated antibody) and Russell's viper venom factor X activator-labeled antibody was captured onto an anti-chicken immunoglobulin G- or avidin-coated plate. The approach was found to be highly sensitive, but the assay relies on a sophisticated amplification system utilizing a snake venom coagulation factor and is limited by its complexity and reagent expense. Poli et al. (24) developed a modified enzyme-linked immunosorbent assay (ELISA) method for serotypes E and F using affinity-purified horse polyclonal antibodies directed against the 50-kDa C fragment of both toxin E and toxin F. An extensive collaborative study for an amplified ELISA for A, B, E, and F was reported by Ferreira et al. (16). The amplified ELISA was compared with the AOAC International official method for the detection of C. botulinum toxins in foods and found suitable to be a preliminary test for the toxin detection and typing. Fach et al. (14) developed a PCR-based identification system which was able to detect even 1 cell of C. botulinum type A or B and 10 cells of C. botulinum type E strains in the samples. The method is sensitive; however, it can take a relatively longer time to perform (a minimum of 5 to 6 h for ELISA and overnight culture enrichments) than the biosensor for C. botulinum toxin detection developed by Ogert et al. (23) and Singh and Silvia (29), which offers fast throughput screening but requires expensive instrumentation. Therefore, it is important to search for cost-effective and practical assay methods capable of analyzing a large quantity of samples in the field. These monitoring assays must be robust and easy to perform.
In recent years, there has been a growing interest in developing low-cost lateral-flow assays (LFDs) for the rapid identification of analytes and pathogens (2, 19, 26, 25, 30, 31). Primarily, these assays are based on an immunochromatographic procedure that utilizes antigen-antibody reaction on a nitrocellulose membrane that is indicated by a color band from attached gold beads. The sensitivity of the lateral-flow assay (10 to 20 ng/ml) was found to be much less than those of certain ELISA kits (100 to 1,000 pg/ml). While conventional lateral-flow assays provide only a visual assay result able to detect analytes in the nanogram range, they are user friendly, relatively inexpensive, and ideally suited for on-site testing by minimally trained personnel and can be adaptable for high-throughput laboratory or field use. However, lateral-flow assays do have a major limitation: they deliver only qualitative results, i.e., a "yes" or "no" answer detected by the human eye. Manufacturers have been developing rapid tests that deliver quantitative results, some of which are being commercialized with some success. The most common readers translate line intensity into analyte concentration and use either colorimetric reflectance or a charge-coupled-device camera to measure the signal intensity. However, like other rapid assays, sophisticated instruments limit the detection time and require trained analysts. Other commercially available readers use the emittance of a fluorescent label that is fixed to conjugate particles. In this study, we evaluated two immunodetection kits for the detection of BoNT type A (BoNT/A), BoNT/B, and BoNT/E in foods and developed procedures to extract the toxin from food samples.
|
|
|---|
Neurotoxins.
Pure neurotoxin complexes of types A, B, and E were purchased from Metabiologics, Inc. (Madison, WI). They were prepared from A strain Hall, B strain Okra, E strain Alaska, and type F strain Langeland. A sodium dodecyl sulfate-polyacrylamide gel electrophoresis gel obtained from Metabiologics indicated a pure neurotoxin complex preparation. The protein concentration was determined at 595 nm on an ELx801 Ultra microplate ELISA plate reader (Bio-Tek Instrument, Winooski, VT) using the Bio-Rad protein assay kit according to the procedure of Bradford (5).
C. botulinum detection kits.
The Bot-Tox-BTA kit for the detection of BoNT/A was purchased from Alexeter Technologies (Tetracore), and kits from BioThreat Alert (Gaithersburg, MD) and from the Naval Medical Research Center (NMRC), Silver Spring, MD, were purchased for detecting BoNT/A, -/B, and -/E. These kits can be obtained commercially. These tests utilize a combination of antibodies to selectively detect the C. botulinum neurotoxin in aqueous samples. The methods and protocols used to make these devices have proprietary rights reserved with the manufacturers, and the source, type of antibody, purification, characterization, and the affinity protocols have not been disclosed by the Department of Defense and Alexeter Technologies. The kits provided by the Naval Medical Research Center were developed by the U.S. Army Medical Research Institute for Infectious Diseases' Critical Reagent Program for Chemical and Biological Defense at the Aberdeen Proving Ground in MD. The kits were used according to the manufacturers' instructions.
Culture conditions and growth of C. botulinum strains.
Type A strains were grown anaerobically in a Bacto cooked meat medium (CMM; Difco Laboratories, Detroit, MI) overnight at 35°C. One milliliter of overnight-grown culture was transferred to Trypticase-peptone-glucose-yeast extract broth (TPGY) and grown at 35°C for 5 days. The culture material was clarified by centrifugation at 10,000 x g for 10 min followed by sterile filtration through a 0.45-µm-pore-size bacteriological Acrodisc filter. Culture filtrate was stored at 4°C until used.
Sample preparation.
Control samples of botulinum neurotoxin complexes A, B, and E (range, 0.2 to 1 µg/ml) were prepared in 500 µl of sample buffer supplied with each test kit. For liquid food samples such as orange juice, bottled water, soft drinks, vanilla extract, and apple juice, a 5-ml food sample was spiked with 100 ng/ml of pure neurotoxin complex A or B or 200 ng/ml of pure neurotoxin complex E and incubated for 30 min at room temperature (25°C). The samples were then centrifuged at 7,000 x g (Eppendorf Brinkmann Inc.) for 30 min at 4°C to remove solid particles. Subsequently, 500 µl of the supernatant was thoroughly mixed with 500 µl of sample buffer in a glass test tube and used for the assay.
High-fat-content and viscous foods such as ice cream, milk, and honey were spiked with 100 ng/ml of pure botulinum neurotoxin complex A, B, or E and incubated for 30 min at room temperature (25°C). The samples were then diluted to a ratio of 1:5 in a sample buffer (0.01 M phosphate buffer, pH 7.4). After incubation, the samples were centrifuged at 7,000 x g for 30 min at 4°C to remove solid particles and/or the lipid layer. Subsequently, 500 µl of the supernatant was thoroughly mixed with 500 µl of sample buffer in a glass test tube and used for the assay.
For semisolid food samples, 10 g of food was spiked with 200 ng/ml of botulinum neurotoxin complex A or B or 400 ng/ml of neurotoxin complex E in separate vials and incubated for 30 min at room temperature (25°C). After incubation, the samples were mixed with 10 ml of sample buffer and homogenized with a bench top stomacher (Seward, Cincinnati, OH) to make a homogeneous suspension. For solid food, a 10-g portion of the food sample was spiked with 200 ng/ml of pure neurotoxin complex A, B, or E and incubated at room temperature (25°C) for 30 min. The portion was then chopped into small pieces by hand, thoroughly mixed with 10 ml of sample buffer, and homogenized with a bench top stomacher to make a homogeneous suspension. The food-buffer mixture was centrifuged at 7,000 x g for 30 min at 4°C to remove solid particles. Five hundred microliters of food sample supernatant was thoroughly mixed with 500 µl of sample buffer in a glass test tube and used for the experiment.
An organic solvent extraction was performed for milk-based food samples. A 5-ml food sample was spiked with 200 ng/ml of pure neurotoxin complex A or B or 400 ng/ml of neurotoxin complex E and incubated at room temperature (25°C) for 30 min. After incubation, the sample was centrifuged at 7,000 x g for 10 min to remove the solid particles. The supernatant was carefully removed and mixed with 5 ml of 50% methanol (vol/vol) in sterilized distilled water. The sample was then thoroughly mixed and allowed to settle at room temperature (25°C). The upper layer containing solvent and lipids was removed by Pasteur pipette, and the remaining lower portion of aqueous mixture was used for the experiment.
In order to reduce the matrix interference of samples which were found negative when they were undiluted, we spiked foods with a 10-fold-higher concentration of toxin and then diluted them 10-fold in a 0.01 M phosphate buffer, pH 7.4, to adjust the final concentration to 10 ng/ml for BoNT/A and -/B and 20 ng/ml for BoNT/E. To check dilution error, the protein concentrations of undiluted and diluted samples were determined at 595 nm on an ELx801 Ultra microplate ELISA plate reader (Bio-Tek Instrument, Winooski, VT) using the Bio-Rad protein assay kit according to the procedure of Bradford (5). The standard error was calculated to be 0.0166 (n = 3) for diluted protein concentrations in the buffer samples. Therefore, we assumed that the diluted samples contained protein concentrations of 10 ng/ml for BoNT/A or -/B or 20 ng/ml for BoNT/E.
Principle and test procedure.
The assay works on an immunochromatographic principle. The BoNT-containing liquid sample rehydrates the antitoxin antibody that is labeled with gold nanoparticles. The toxin-antibody complex then migrates via capillary action along the nitrocellulose membrane placed between two plastic strips. In the sample window, the BoNTs bind with the antitoxin antibody-gold particle conjugate and forms a red line in the sample window. The intensity of the red color on the test line is directly proportional to the amount of BoNT present in the sample. The red line on the control window acts as a positive control to assure that functional, conjugated antibody has migrated throughout the system (Fig. 1A). A colored line in the control window should always appear regardless of the presence or absence of neurotoxin in the sample. For each food sample and culture filtrate, three individual tests were performed in triplicate (n = 3). Unless otherwise stated, the results represent all three tests, whether positive or negative. For sensitivity studies, each toxin type (BoNT/A, -/B, or -/E) was tested in triplicate with three independent experiments (n = 3).
![]() View larger version (47K): [in a new window] |
FIG. 1. (A) Schematic representation of the lateral-flow assay. A mixture of target BoNT and antibody migrates by capillary force to the membrane toward the capture zone. (B) Overview of a lateral-flow assay. The antibodies specific to a toxin immobilized onto a membrane at the test line position as shown in the sample window in the panel. These antibodies will react only with the BoNT toxin. There is also a control line, as shown in the control window in the figure, which indicates whether the test has worked or not. If a sample is positive for BoNT, there will be two lines in the viewing windows (sample and control); if negative, there will be only one at the control line position. If there is just one line at the test line position, the result should be ignored and considered invalid.
|
|
|
|---|
Milk products.
The Alexeter Technologies kit showed poor filtration and migration of the high-fat-content samples compared to that of the NMRC kit. These samples filtered poorly through the filtration device and were unable to migrate to the control window (Table 1). However, a clear red-colored line appeared in the sample window, indicating a positive reaction. With the NMRC kit, the samples, except for whipping cream, reached the sample and control windows within 15 min (Table 2). Both BoNT/A and -/B assay kits exhibited similar results. In the case of the BoNT/E assay, samples such as whipping cream, half-and-half, and raw milk showed negative results. Very slow migrations of the samples were observed (Table 2).
|
View this table: [in a new window] |
TABLE 1. Detection of BoNT/A and -/B in milk samples using Alexeter Technologies-developed lateral-flow in vitro bioassaya
|
|
View this table: [in a new window] |
TABLE 2. Detection of BoNT/A, -/B, and -/E in milk samples using NMRC-developed lateral-flow in vitro bioassaya
|
It was assumed that the slow filtration could be due to the presence of lipid in the samples and that an organic solvent may dissolve or separate the fat from the aqueous solution. Therefore, we used the organic solvent methanol to partition the toxin. After extraction, the lower aqueous layer was applied to the kit. No color line appeared in either the sample or the control window. Similar results were observed for both manufacturers' kits (Tables 1 and 2).
Solid foods, liquid foods, and seafood.
A wide variety of food samples, including liquid, solid, and semisolid food and seafood, were tested. Of the 33 solid and liquid foods, only 10 foods showed a positive test endpoint within 15 min when used in undiluted forms. Ice cream, orange juice, and honey gave negative results with the Alexeter Technologies kit. These food samples were found positive after being diluted to a ratio of 1:10 in a sample buffer (Table 3).
|
View this table: [in a new window] |
TABLE 3. Detection of Clostridium botulinum neurotoxin in food samples using Alexter Technologies' lateral-flow-based in vitro bioassaya
|
|
View this table: [in a new window] |
TABLE 4. Detection of Clostridium botulinum neurotoxin in food samples using lateral-flow-based in vitro bioassay
|
Detection of cultured toxin and specificity.
Seventy-seven strains of Clostridium botulinum type A isolated from different environmental and clinical samples were chosen for the detection of the cultured toxin. These strains are isolates of outbreaks and are from a Food and Drug Administration Clostridium botulinum depository. The culture filtrate from each isolate was diluted 100-fold in a 0.01 M phosphate buffer, pH 7.4, before being used in the assay. Further attempts to dilute the cultured toxin (1 x 103 dilution) failed, and negative results were observed. Except for strain CS-A, all strains showed positive results when grown in TPGY medium. Culture filtrates of four strains, i.e., SKOR1-A (8833B1), SKOR@-A (8933E1), CS-A, and 8-A, grown in a CMM medium were found negative for the presence of BoNT/A. In order to test for false-positive results, we used denatured BoNT/A complex (heated at 100°C for 10 min), pure BoNT/E and -/F complexes, tap water, bovine serum albumin, purified hemagglutinin-33 (from BoNT/A complex), and culture filtrates of 26 other nonbotulinum strains, including strains of Clostridium acetobutylicum, Clostridium chauvoei, Clostridium sporogenes, Clostridium histolyticum, Clostridium tetani, Clostridium bifermentans, Clostridium sordellii, Clostridium perfringens, Bacillus subtilis, Bacillus cereus, and Bacillus megaterium as interfering agents. No false positives were observed for 26 of the culture filtrates of 26 strains or for other interfering agents except for BoNT/F. A very faint positive line appeared in sample windows with BoNT/F samples.
|
|
|---|
The assays were visualized as red lines created by the bound colloidal gold; therefore, sensitivity is limited to what can be seen by the human eye and is lower than that of sensitive instrumentation such as a spectrophotometer or a fluorescent reader. Typically, an arbitrary quantitation of the detection sensitivities of these assays is done by assigning "plus" and "minus" values, with the increasing intensity of the red line assigned a plus value. Besides the somewhat qualitative nature of this process, the weak-positive-result values can vary based on the skill of the technician responsible for validating a given lot of assays.
The lethal dose of botulinum toxin for humans is not precisely known. The estimated lethal amount of crystalline type A toxin for a 70-kg human would be approximately 0.09 to 0.15 µg intravenously or intramuscularly, 0.70 to 0.90 µg inhalationally, or 70 µg orally (4) The detection limit of the mouse bioassay is 10 pg/ml of pure BoNT/A (11). We found that the BoNT/A and -/B assay kits can readily detect 10 ng/ml, while the BoNT/E kit can detect as low as 20 ng/ml of BoNT/E. Although these assays exhibited sensitivities less than the detection limit of the mouse bioassay, they are capable of detecting the toxin concentration that can cause botulism disease symptoms in humans. Therefore, they can be considered for large-scale or presumptive test screening to be followed by a confirmatory mouse bioassay.
Certain milk-based samples, such as whipping cream, half-and-half, and raw milk, when tested in undiluted form, exhibited low filtration or sometimes virtually no filtration with these test devices. Such problems were particularly encountered by the Alexeter Technologies kits. The test kits from NMRC performed relatively well in terms of filtration and sample migration of the analytes. They developed filtration and sample migration problems only with whipping cream. This was perhaps due to the high fat contents of these milk products (Table 5). In general, the filtration system prevents the solid particles and passes analytes (toxin) freely to the membrane. Lateral-flow assays work on the basis of a capillary process (2, 25) and, because of the action of capillary forces, the toxin has to migrate up the membrane to where ligands are immobilized in the capture zones. It seems that the high fat contents of the samples prevent the capillary flow of the samples. However, several other factors could cause negative results, including the inhibition of antigen antibody reaction due the presence of inhibitory enzymes present in the samples.
|
View this table: [in a new window] |
TABLE 5. Milk product contentsa
|
These lateral-flow tests can detect up to 100-fold dilutions of the cultured toxin in both TPGY medium and CMM, indicating that undiluted cultured toxins of foods can be tested for a qualitative identification of BoNT. The choice of medium and its constituents can also affect the overall results of the assay. For example, of the 77 strains grown in CMM, the assay showed three false-negative results. In the TPGY medium, no false negatives were observed, and all strains (except CS-A) showed positive reactions. Except for BoNT/F, other potentially interfering agents did not give false-positive results, perhaps indicating that a weak cross-reaction of BoNT/F antibodies occurs with BoNT/A and -/B.
The ELISA method, which can detect from 0.1 to 1 ng/ml (
10to 100 MLD) of the toxin in a variety of samples, including food, has been widely used by researchers (15) and is commercially available from Metabiologics, Inc. The modified ELISA was compared with the AOAC International method and proved useful for screening a large quantity of samples. The assay takes approximately 5 h to complete. The major disadvantage of ELISA is that it is relatively time and labor intensive. Unlike the typical ELISA, in which either antibodies or antigens are directly bound to a polystyrene or polyvinyl microplate, electrochemiluminescence detection offers relatively better sensitivity (0.05 to 1.0 ng/ml,
10 MLD) through a process in which antibodies are attached on the magnetic particles in a large volume of sample suspension and then captured and bound in a small area. Electrochemiluminescence detection provides increased sensitivity due to high luminescent-signal-to-noise ratios. However, the assay performance could vary significantly depending on the sample matrices. Because of this, matrix-specific positive and negative control samples are used to establish standard curves and cutoff values. An expensive instrumentation is also a major limitation with the assay. Lateral-flow assays are simple to use and require minimal training. They are relatively cost effective and can be used as first-responder detection kits. Although these devices sound ideal, they have limitations. Key limitations are that they are less sensitive than other in vitro detection systems and that the assessments of results are strictly qualitative. New-generation lateral-flow assays based on fluorescence have substantially greater sensitivities and dynamic ranges than did the ones used in this study. Nevertheless, the development of such assays has been limited by the need for stable dyes that do not cause sample interference and by the fact that the instrumentation required was both complex and expensive.
In summary, the performance of the LFDs indicates that these assays are suitable as screening tools for a variety of foods potentially contaminated with BoNT. The speed of the assay (15 min), in concert with proven precision, demonstrates its usefulness in testing samples when used by trained laboratory operators. However, an extra 15 min of incubation time needs careful evaluation and enzyme and antigen antibody standardization before it can be used for large-scale screening. However, due to their relatively insensitive natures, they can be used as presumptive tests only, and the mouse bioassay should be used for confirmatory results. Ease of operation and consistent results suggest that the LFDs can be effectively used by nontechnical staff for screening food samples
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»