Applied and Environmental Microbiology, February 2006, p. 1180-1189, Vol. 72, No. 2
0099-2240/06/$08.00+0 doi:10.1128/AEM.72.2.1180-1189.2006
Copyright © 2006, American Society for Microbiology. All Rights Reserved.
Proteomic and Biomolecular Mass Spectrometry Center, Institute of Food Science and Technology, CNR, Avellino, Italy,1 Department of Food Science, University of Udine, Udine, Italy2
Received 19 September 2005/ Accepted 9 November 2005
|
|
|---|
|
|
|---|
Traditional methods for bacterial identification and classification, which are based on analysis of morphological, physiological, and biochemical features or genetic approaches (DNA-DNA or RNA-DNA hybridization, determination of G+C contents of DNAs,), are now complemented by sequence analysis of small-subunit rRNAs by PCR methods (3, 10, 20, 36, 45). Notwithstanding these recent developments, alternative complementary analytical approaches that ensure minimal time consumption, low cost, high accuracy, and sensitivity are still an area for investigation.
Mass spectrometric methodologies have been used for bacterial characterization since 1975 (1), and the first results were obtained by pyrolysis mass spectrometry (MS) (23, 25, 28, 42), fast atom bombardment mass spectrometry (7, 27), gas chromatography-mass spectrometry (19), and electrospray ionization mass spectrometry (17, 24, 56). However, significant progress in this field was marked by the introduction of matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (29, 33). Briefly, in MALDI-TOF MS samples are mixed with an appropriate matrix material, and upon laser irradiation, sample molecules are ionized and desorbed as gaseous ions. These ions are accelerated and transferred to an analyzer, where they are separated and detected based on the ratio of molecular weight to charge (m/z). The advantages of this technique, such as the remarkable tolerance for contaminants and the ability to simultaneously detect different components in a broad m/z range present in complex mixtures, made it possible to analyze intact bacterial cells by mass spectrometry (ICMS) for the first time. Due to experimental conditions used during the MS analysis, particular surface components and/or proteins released from bacterial cells after partial cellular lysis are ionized, giving rise to signals at different m/z values (18, 41). Therefore, the mass spectra can be considered specific fingerprints or molecular profiles of the bacteria analyzed. Since the introduction of the strategy in 1996 (5, 30), researchers have realized that this method could become a rapid method for bacterial discrimination that involves minimal sample handling. In the last 10 years, several protocols for ICMS analysis have been proposed. In fact, the reproducibility and accuracy of mass spectra can be affected by different experimental conditions, such as the culture medium, the growth time, the bacterial concentration, sample preparation, and the MALDI matrices (13, 14, 22, 40, 41, 43, 49, 51, 57). At the same time, bioinformatic tools were developed in order to use mass spectrometric data for bacterial identification by means of searches either in protein databases available on the Web or in mass spectrum reference libraries constructed in house. The whole body of publications led to the conclusion that highly reproducible and accurate mass spectral profiles having characteristic peaks in the m/z range up to 15,000 Da can be obtained by ICMS, thus allowing rapid identification and/or discrimination of bacteria belonging to different genera and species (2, 4, 11, 12, 32, 34, 48, 58, 61).
Here, we describe an extensive ICMS study carried out with the most common food-borne pathogens. In particular, a systematic study of several species belonging to the genera Escherichia, Yersinia, Proteus, Morganella, and Salmonella, reported in detail here for the first time, resulted in a more comprehensive picture of the family Enterobacteriaceae. Moreover, as an example of a useful application, 25 Escherichia coli strains were analyzed, which resulted in unambiguous identification of E. coli O157:H7. Finally, the results obtained for five species belonging to the genus Listeria are reported below as a clear example of ICMS analysis of gram-positive bacteria.
Mass spectrometric data were processed by using original data processing software, and bacterial molecular profiles truly representative of the species analyzed were obtained. Molecular profiles of all the bacteria analyzed were collected in order to set up a database to identify food contaminant microorganisms that cause human diseases (http://bioinformatica.isa.cnr.it/Descr_Bact_Dbase.htm). At present, this database contains information on about 50 bacterial strains belonging to 24 species and, among the databases that are freely available, it is the most complete database for the genera analyzed in this study.
In the near future, analytical tools developed in the present study could become a reliable approach for rapid screening of bacterial species to better direct microbiological investigations toward the detection of specific pathogens.
|
|
|---|
-cyano-4-hydroxycynnamic acid were purchased from Sigma (St. Louis, Mo.). Trifluoroacetic acid (TFA) and all the organic solvents used were the highest purity available from Carlo Erba (Milan, Italy). Nutrient broth (NB), tryptone soya agar, tryptone soya broth (TSB), tryptone, and yeast extract were purchased from Oxoid (Basingstoke, Hampshire, United Kingdom). A third culture medium, tryptone yeast broth (TYB), was prepared using 5 g liter1 tryptone and 2.5 g liter1 yeast extract at pH 7.0.
Bacterial cultures.
Bacterial cultures (Table 1) were obtained from the American Type Culture Collection (Manassas, Va.), from the Deutsche Sammlung von Mikroorganismen und Zellkulturen GmbH (Braunschweig, Germany), from the National Collection of Type Cultures (PHLS Central Public Health Laboratory, London, United Kingdom), and from the Department of Food Science of the University of Udine, Udine, Italy.
|
View this table: [in a new window] |
TABLE 1. Bacterial strains analyzed
|
Bacterial growth was determined both by plate counting on tryptone soya agar and by measuring the optical density at 600 nm. Frozen samples were prepared by storing fresh bacterial cultures in 10% dimethyl sulfoxide (DMSO) or 20% glycerol at 80°C.
Finally, three bacterial cultures were produced for each strain using the optimized protocol.
Sample preparation and loading on MALDI target plate.
One-milliliter aliquots of a bacterial culture containing 1 x 109 cells, as determined by optical density, were centrifuged at 13,000 rpm for 5 min to collect the cells, and the supernatants were discarded. For sample preparation for MALDI-TOF MS analysis, we used a method based on the method described by Dai and coworkers (9). Cellular pellets were washed once in 1 ml of water and twice in 1 ml of 0.2% TFA. After each step samples were centrifuged at 13,000 rpm for 5 min. The pellets were dissolved by vortexing for 2 min in an appropriate volume of 0.2% TFA to obtain cell concentrations ranging from 103 to 108 cells µl1.
Aliquots (0.5 µl) of a bacterial suspension were deposited on a MALDI target plate, mixed with 0.5 µl of matrix (10 mg ml1
-cyano-4-hydroxycynnamic acid in 50% acetonitrile containing 1 pmol µl1 of cytochrome c as an internal standard), and dried under ambient conditions. Then 0.5 µl of matrix solution was added to each well and dried under ambient conditions. Frozen and lyophilized samples were prepared and analyzed by using the protocol described below.
Data acquisition and processing.
All mass spectra were acquired with a Voyager DE PRO MALDI-TOF mass spectrometer (Applied Biosystems, Foster City, Calif.) operating in the linear, delay extraction, positive-ion mode. The laser intensity (N2, 337 nm) was set just above the ion generation threshold. The low mass gate was set to m/z 2,400, the delay time was 550 ns, the accelerating voltage was 25,000 V, and the grid voltage and guide wire were set to 95% and 0.3% of the accelerating voltage, respectively. From the three cultures produced for each bacterial strain, triplicate mass spectra were acquired by accumulating 100 laser shots in the m/z range from 2,500 to 15,000. Spectra were calibrated using as internal standards the double and singly charged peaks that originated from cytochrome c (m/z 6,181 and 12,361, respectively) so that the error for the experimental mass measurements was less than 5 Da. All mass values were reported as average masses. The background was subtracted from the mass spectra, and the spectra were smoothed with Gaussian smoothing with the filter width set to 11 points. Data lists containing m/z values and corresponding peak intensities were extracted from mass spectral data with the specific software of the instrument (Data Explorer, version 4.0.0.0) by means of a macro in the Visual Basic language provided by the producer. Signals with intensities greater than 5% were included in the lists. Data lists were further processed with original data processing software developed in the Visual Basic language as a Microsoft Excel application. The program selected m/z values present in all nine spectra acquired for each bacterial strain, taking into account a tolerance error of ±7 Da, and it calculated arithmetic means and standard deviations both for m/z values and for the corresponding intensities. The accuracy of mass measurements was such that the standard deviation was less than ±3 Da. The specific peak lists generated by this program constituted the bacterial molecular profiles. Species-specific biomarkers were extracted by comparison of the peak lists obtained.
|
|
|---|
In order to test the reproducibility and accuracy of the ICMS analysis, three bacterial cultures were produced in TSB on different days; each sample was loaded into three wells of a MALDI target plate, and mass spectra were acquired in triplicate. Electronic processing (as described in Materials and Methods) of the mass spectrometric data obtained from the analysis of a single culture allowed us to obtain a peak list containing around 50 peaks, and, considering all 27 mass spectra acquired, a lower number of constant signals (34 peaks) was obtained. This confirmed that there was a certain variability in the mass spectra obtained from different cultures. Therefore, all the experiments described below were carried out with three different bacterial cultures grown over a period of 3 months, and triplicate mass spectra were acquired from each bacterial culture.
To test the effects of different culture media and growth times, E. coli ATCC 25922 was grown in NB, TYB, and TSB, and 1-ml aliquots of each broth culture were taken at 18 h, 24 h, and 48 h. Different growth times did not affect the bacterial molecular profiles significantly (data not shown), while some differences were discerned in the mass spectra obtained from the analysis of E. coli grown in different culture media. However, it was possible to extrapolate a set of at least 15 signals present in all the mass spectra obtained from the analysis of bacteria grown in different culture media, while there were major differences in the peak intensities (Fig. 1; see Table SA in the supplemental material). High-quality mass spectra were obtained by analyzing E. coli samples grown in TSB, since they had the greatest number of signals and the highest signal-to-noise ratio. To minimize the influence of medium composition on mass spectra, TSB was used for all subsequent experiments.
![]() View larger version (19K): [in a new window] |
FIG. 1. Mass spectrometric profiles obtained from the analysis of E. coli ATCC 25922 grown in different culture media, including TYB (A), NB (B), and TSB (C). Signals that the profiles have in common are indicated by dots in panel C.
|
In conclusion, the best experimental conditions for obtaining good-quality and highly reproducible spectra were as follows: bacterial cells grown in TSB at 37°C for 24 h and analyzed directly by spotting 1 x 106 cells in each well.
Bacterial strains listed in Table 1 were analyzed using the optimized protocol, and mass spectrometric data were processed by means of the electronic processing program. Peak lists that contained the most reproducible and significant signals that originated from the mass spectrometric analysis constituted unambiguous molecular profiles of the bacterial species analyzed. These molecular profiles and representative mass spectra were used to create a specific database, designated "FoodBIMS," which is freely available on the website http://bioinformatica.isa.cnr.it/Descr_Bact_Dbase.htm.
Results obtained for species belonging to the family Enterobacteriaceae and the genus Listeria are described in detail below. Results obtained for the other species have been uploaded in the database due to the great amount of experimental data.
Definition of molecular profiles of species belonging to the family Enterobacteriaceae and the genus Listeria.
For the genus Yersinia, four species that are widely found as food contaminants were analyzed, Yersinia enterocolitis, Yersinia kristensenii, Yersinia frederiksenii, and Yersinia intermedia,. The ICMS analysis gave mass fingerprints containing a different number of peaks for each species, and the number of peaks ranged from 20 to 35 (Fig. 2 and Table 2). The four species could be easily discriminated by means of a direct comparison of the mass spectra. In fact, by using electronic processing, we found that the most intense signals corresponded to the species-specific biomarkers and no genus-specific biomarkers could be defined.
![]() View larger version (21K): [in a new window] |
FIG. 2. Mass spectrometric profiles obtained from the analysis of Yersinia species, including Y. enterocolitica (A), Y. intermedia (B), Y. frederiksenii (C), and Y. kristensenii (D). Species-specific biomarkers are indicated by dots.
|
|
View this table: [in a new window] |
TABLE 2. Peaks obtained from the analysis of four Yersinia speciesa
|
![]() View larger version (23K): [in a new window] |
FIG. 3. Mass spectrometric profiles obtained from the analysis of Escherichia species, including E. fergusonii (A), E. hermannii (B), E. vulneris (C), E. blattae (D), and E. coli (E). Species-specific biomarkers are indicated by dots.
|
Finally, the two Proteus species, Proteus vulgaris and Proteus mirabilis, and Morganella morganii had very different molecular profiles and could be easily discriminated (see Table SD in the supplemental material).
Gram-positive bacteria produced mass spectra that had a lower number of strong signals than the spectra of gram-negative bacteria, as revealed by the analysis of Staphylococcus aureus, Listeria spp., Lactococcus lactis, Leuconostoc mesenteroides, Micrococcus spp., and Sarcina flava (see the website http://bioinformatica.isa.cnr.it/Descr_Bact_Dbase.htm). In particular, the five Listeria species analyzed in the present study (Listeria monocytogenes, Listeria innocua, Listeria ivanovii, Listeria welshimeri, and Listeria seeligeri) exhibited very similar mass fingerprints. Six genus-specific biomarkers were detected together with species-specific biomarkers (Fig. 4; see Table SE in the supplemental material). Interestingly, L. welshimeri had very peculiar mass spectra; in fact, as many as 13 biomarkers were present, and the most intense signal was at m/z 6,392 instead of at m/z 6,362, as detected for all the other species. These signals could have originated from the same protein having a slightly different amino acid sequence in L. welshimeri. The mass spectra of L. monocytogenes and L. innocua had 76% peaks in common, and these species could be discriminated on the basis of a few biomarkers.
![]() View larger version (20K): [in a new window] |
FIG. 4. Mass spectrometric profiles obtained from the analysis of Listeria species, including L. monocytogenes (A), L. seeligeri (B), L. welshimeri (C), L. innocua (D), and L. ivanovii (E). Species-specific biomarkers are indicated by dots.
|
The mass spectra obtained from the analysis of the E. coli strains were very similar. In the mass spectral profiles of all the E. coli O157:H7 strains the most intense signal was at m/z 9,740, whereas a signal at m/z 9,060, which was present in the mass spectra obtained for non-O157:H7 E. coli, was never found (Fig. 5). These features made the mass spectral profiles of E. coli O157:H7 unique and allowed us to unambiguously identify this pathogen.
![]() View larger version (29K): [in a new window] |
FIG. 5. Mass spectrometric profiles obtained from the analysis of E. coli O157:H7 (A) and non-O157:H7 E. coli (B). The signal at m/z 9,740 is indicated by a dot in panel A, and the signal at m/z 9,060 is indicated by a dot in panel B.
|
|
|
|---|
The present study was performed to analyze common food-borne microorganisms and to develop an additional analytical tool for rapid detection of pathogens. The capacity of ICMS to discriminate bacteria was ascertained by analyzing closely related species belonging to the genera Escherichia, Yersinia, Salmonella, Proteus, and Morganella representing the family Enterobacteriaceae and five Listeria species representing the gram-positive bacteria; the latter taxa have not been described in detail so far.
As reported previously, the reproducibility and soundness of the data acquired with regard to different experimental parameters are fundamental (18). Therefore, we optimized a protocol for preparation of bacteria and ICMS analysis which was strictly followed throughout the present study in order to improve the reproducibility of mass spectra.
The use of a single culture medium for all the bacterial species analyzed did not affect the results obtained; moreover, it prevented the presence of nonspecific signals which could be due to culture media. In fact, our results showed that a representative pattern of signals is always present in the mass spectra regardless of the medium used for bacterial growth, in agreement with the results reported by Valentine and coworkers (57).
Our study resulted in highly reliable and reproducible lists of peaks that were specific molecular profiles suitable for discriminating the 24 bacterial species examined.
Interestingly, in the family Enterobacteriaceae, no genus-specific biomarker could be found for the genus Yersinia, and only two signals are shared by all the Escherichia species. On the other hand, E. coli and Salmonella have a great number of signals in common, and a few biomarkers that were significant allowed us to discriminate between E. coli and E. fergusonii. This confirms that DNA-DNA relatedness can show up in mass spectrum profiles; in fact, E. coli and Salmonella, as well as E. coli and E. fergusonii, are very closely related (15, 38). Moreover, M. morganii, previously classified in the genus Proteus, does not have any signal in common with the two Proteus species according to the low level of DNA-DNA relatedness (<20%) (44).
The Listeria species selected for this study are very closely related to each other, belonging to the same subgroup (50); in fact, six genus-specific biomarkers could be defined. In addition, L. monocytogenes and L. innocua, which are discriminated with difficulty by traditional and genetic microbiological approaches, had very similar molecular profiles with a few species-specific biomarkers that resulted in unambiguous identification by ICMS analysis, while the other species could be differentiated more easily.
A thorough study of E. coli species showed that defining strain-specific biomarkers is difficult when a good number of strains are analyzed (25 strains were analyzed in our study) because it is more likely that signals are shared by different strains. However, our results led to unambiguous and clear identification of E. coli O157:H7, as also reported by Bright and coworkers, who used a different approach for processing mass spectrometric data (4). Computational processing of mass spectrometric data showed that bacterial strains with the O157:H7 antigen had very peculiar features in their MALDI spectra; more specifically, a very strong signal at m/z 9,740 was consistently present, and there was no signal at m/z 9,060, which was present in the mass spectra of all the other E. coli strains. In E. coli 1090, a non-O157:H7 strain, these signals were correlated with the mature forms of acid-resistant proteins HdeA and HdeB, respectively, after proteolytic cleavage of the peptide signal by the peptidase Lep (31). However, the length of the signal sequence of the HdeB protein in E. coli O157:H7 has not been reported yet, and the definition of a consensus sequence for peptidase Lep is still being studied (35). It could be hypothesized that E. coli O157:H7 expresses a slightly different mature form of HdeB, thus explaining the absence of the corresponding signal (m/z 9,060) in the mass spectra. For the signal at m/z 9,740, which was present only in seven of the non-O157:H7 E. coli strains analyzed in this study, it is not possible to rule out the possibility that in E. coli O157:H7 the signal could also originate from other proteins peculiar to this microorganism, such as those involved in pathogenicity.
Analysis of E. coli O157:H7 by bacteriological methods still requires a great number of tests in order to obtain conclusive identification (16, 54). The results of recent methodologies based on PCR or biosensor technology suggest that methods for rapid and reliable detection of E. coli O157:H7 still need further development (8, 39). In this regard, ICMS analysis, which requires just a few minutes for unambiguous identification of this pathogen, is worth considering. Additionally, the ICMS approach could discriminate between Y. enterocolitica and Y. enterocolitica-like species more efficiently than other methods that have been described (55). ICMS analysis also led to successful discrimination of two Salmonella serovars, although a wider study of different serovars is needed to definitively asses the capability of the methodology for this task.
The applicability of ICMS to bacterial identification relies strictly on the availability of specific bioinformatic tools. Several workers have focused on the construction of reference libraries of mass spectra (2, 4, 34) and/or on the development of peculiar algorithms to use mass spectrometric data to identify bacteria by means of searches in protein databases available on the Web (11, 12). To the best of our knowledge, so far neither mass fingerprint databases nor mass spectrum reference libraries are available at no cost online. On the other hand, a problem in the identification of bacteria using lists of m/z values for searches in protein databases based on Swiss-Prot/TrEMBL or NCBInr data arises from the low number of protein entries for bacteria whose genomes have been only partially sequenced. In fact, while there are about 23,000 and 93,000 protein entries for E. coli in the Swiss-Prot/TrEMBL and NCBInr databases, respectively, and 7,062 and 30,047 protein entries for L. monocytogenes, the numbers are drastically lower for other Escherichia, Yersinia, Proteus, Morganella, and Listeria species, as shown in Table 3. Additionally, postbiosynthetic processing of cellular proteins can often make it difficult to match signals present in mass spectra to the corresponding protein entries in the databases (37).
|
View this table: [in a new window] |
TABLE 3. Numbers of protein entries in databases
|
At this time, our database is one of the most complete collections of bacterial molecular profiles determined by ICMS analysis, and we believe that this approach, which complements the well-established methods, could become a key tool in food safety control and in clinical microbiology.
We thank Marie De Vito for revising the manuscript.
This article is especially dedicated, with respect and affection, to the memory of Arturo Leone, Head of the Institute of Food Science and Technology of the CNR, who died on 30 December 2005.
|
|
|---|