Applied and Environmental Microbiology, June 2007, p. 3505-3510, Vol. 73, No. 11
0099-2240/07/$08.00+0 doi:10.1128/AEM.01825-06
Copyright © 2007, American Society for Microbiology. All Rights Reserved.

Harry Reid Center for Environmental Studies, University of Nevada, Las Vegas, 4505 S. Maryland Parkway, Las Vegas, Nevada 89154-4009,1 Department of Environmental and Occupational Health, School of Public Health, University of Nevada, Las Vegas, 4505 S. Maryland Parkway, Las Vegas, Nevada 89154-3063,2 Technical Support Working Group, Arlington, Virginia3
Received 2 August 2006/ Accepted 29 March 2007
|
|
|---|
|
|
|---|
While surface sampling methods have been compared for relative effectiveness (1, 4, 12), there is little quantitative information on the collection efficiency of surface sampling methods (2, 8, 10). This research project was designed to evaluate monitoring protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of Erwinia herbicola, a gram-negative vegetative bacterium that is commonly used as a biothreat simulant, on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge (Speci-sponge) and a macrofoam swab (SW Kit), for detection of E. herbicola on surface materials. Laboratory studies were designed to determine the efficiency and sensitivity of the sampling and analysis protocols. Test chamber studies were designed for comparison of methods after aerosol release and settling of E. herbicola cells onto the surface materials.
|
|
|---|
![]() |
Test materials.
Seven surface materials were selected for evaluation. Wood laminate shelves, painted metal file cabinets and shelves, and computer monitors were obtained from excess office furnishings. Other materials obtained from commercial vendors included finished concrete tiles (untreated; Valentine Construction, Henderson, NV), commercial vinyl composition tile (Armstrong Imperial Texture Standard Excellon, World Industries, Lancaster, PA), nylon seat cushions (Quality Upholstery, Las Vegas, NV), and plastic arena seats (double-wall, high-density polyethylene; Hussey Seating Company, North Berwick, ME). For laboratory trials, glass was used as the test material in place of computer monitor screens.
Surface sampling and sample processing.
Two surface sampling methods were tested, a sponge (Speci-sponge; Nasco, Fort Atkinson, WI) and a macrofoam swab (SW Kit, currently named the Sample Collection and Recovery Device; ASD BioSystems, Danville, VA), by using protocols developed in a previous project (4). The protocol for sponge sampling consisted of moistening the dehydrated sterile sponge in a sterile stomacher bag with 30 ml of sterile 0.01 M potassium phosphate buffer (PB, pH 7.0). The hydrated sponge (4.2 by 8.7 cm) was squeezed to remove the excess buffer and then used to sample surface material sections by wiping a 930-cm2 (1-ft2) area in a horizontal direction. The sponge was turned over to expose the unused side and used to sample the same area in a vertical direction, taking care not to disturb the exposed side of the sponge. The sponge was returned to the stomacher bag, and the sample was hand mixed for 1 min. The liquid sample was eluted from the sponge, the volume was measured, and the sponge was discarded.
The protocol for the swab consisted of removing a macrofoam swab (1.6 by 2.0 cm), premoistened with Tris-buffered saline with 0.1% Tween 20, from a sterile pouch. Surface samples were obtained by swabbing the first half of the surface material area, turning the swab over to expose the unused side, and swabbing the second half of the surface material. A total area of 317 cm2 (49 in2) was sampled. The swab was placed in a 50-ml tube containing 9 ml of Tris-buffered saline with 0.1% Tween 20 and vortexed for 1 min. The liquid sample was eluted from the foam swab, the volume was measured, and the swab was discarded.
DNA extraction.
Following sampling and processing, samples were filter concentrated and E. herbicola DNA was extracted and purified (Fig. 1). Twenty milliliters of the sponge samples and 6 ml of the swab samples were concentrated by filtration for subsequent DNA extraction. The DNA extraction and concentration protocol consisted of filtration of the processed sample through a 0.65-µm-pore-diameter mixed cellulose ester filter membrane (Millipore Corp., Bedford, MA) and resuspending the membrane in 0.5 ml of PB with 0.05% Tween 20 (pH 7.0). The concentrated sample was boiled for 15 min and chilled on ice for 2 min, and bovine serum albumin (0.05%, final concentration) was added to block the binding of DNA to the membrane (Fig. 1). The sample was then incubated for 5 min at 37°C in a rotary shaker at a speed of 230 rpm. After removal of the membrane, the DNA was purified by the Pellet Paint protocol (Novagen, Madison, WI), and the purified DNA pellet was resuspended in 50 µl of Tris-EDTA buffer (pH 8.0).
![]() View larger version (17K): [in a new window] |
FIG. 1. Flow chart summarizing sponge and macrofoam swab sample processing and E. herbicola DNA extraction and purification procedures. Abbreviations: PB, 0.01 M PB; TBS, Tris-buffered saline with 0.1% Tween 20; HA, mixed cellulose esters; PBT, 0.01 M PB with 0.05% Tween 20; BSA, bovine serum albumin; TE, Tris-EDTA buffer.
|
1 template per reaction) and the enumeration of 1 template per reaction. The detection limits were calculated with the equation
![]() |
Laboratory trials.
Laboratory trials were conducted with the swab and sponge to determine the efficiency and sensitivity of the surface sampling methods for detection of E. herbicola cells from surfaces. A log-phase culture (optical density at 600 nm, ca. 0.6) of E. herbicola was harvested by centrifugation, washed twice, and resuspended in PB. Cell concentration (CFU per milliliter) was determined by serial dilution, spread plating onto TSAC, and incubation as described above. One-milliliter volumes of the culture, containing a known concentration of cells (108 CFU/ml), were used to inoculate triplicate sections of each test material in a biosafety cabinet, and the materials were covered and allowed to dry. Test materials consisted of wood laminate, glass (to represent computer monitor screens), metal shelves (to represent file cabinets), plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Three samples were collected from each of the seven materials by each sampling method. Sponge and swab surface samples were analyzed by culture and QPCR. For QPCR, 20 ml of sponge samples and 6 ml of swab samples were concentrated by filtration prior to DNA extraction. DNA extraction and purification were performed as described above.
Test chamber trials.
E. herbicola aerosolization trials were conducted in a room-sized test chamber. As previously reported, the room measures 4.0 m by 4.0 m by 2.2 m high and has a sheet vinyl tile floor (5). The interior walls, exterior walls, and ceiling are sheetrocked and coated with interior latex paint. The chamber is equipped with a heating, ventilation, and air conditioning system that is sized to simulate a residential system with rectangular bare metal ductwork. During aerosolization experiments, the heating, ventilation, and air conditioning system was operated with an airflow of 4.2 m3/min, resulting in approximately five room air volume exchanges per h. An anteroom equipped with a HEPA-filtered air shower attached to the room entrance reduces mixing of air resulting from entering and exiting the chamber during experiments. During all activities in the test chamber, technicians wore full-face respirators and nonwoven protective clothing. Upon completion of each series of test chamber trials, contaminated surface materials were either decontaminated or removed and discarded and the interior surfaces of the chamber were decontaminated with a 0.5% sodium hypochlorite solution. For test surface materials, decontamination was followed by rinsing with sterile water.
Three E. herbicola releases were conducted in the test chamber. For each release, seven test materials were placed in the test chamber and sampling areas on each material were identified. Test materials were the same as described above for the laboratory trials, except that an actual file cabinet and computer monitors (power on) were substituted for the metal shelves and glass, respectively. Test materials were oriented horizontally, with the exception of the computer monitor screens, which were oriented vertically. A log-phase culture of E. herbicola was harvested, washed, and resuspended in PB as described above. Ten milliliters of the washed culture was added to a Collison nebulizer (BGI Inc., Waltham, MA), and the nebulizer was placed in the experimental room. With the chamber air-handling system on, the Collison nebulizer was operated at a pressure of 20 lb/in2 for 10 min to aerosolize E. herbicola cells in the room. The bioaerosol concentration was monitored during the release with a BioSampler (SKC, Inc., Eighty-Four, PA) supplied with 20 ml of PB and operated at 12.5 liters/min. The chamber air-handling system was then turned off to allow the bioaerosol to settle onto the test materials. After overnight settling of the bioaerosol, biocontamination levels were measured on surfaces in the chamber over a 2-day period. Surface sampling was conducted on all test surfaces by the sponge and swab sampling methods. The first set of samples was collected on day 1, and duplicate samples were collected on day 2 for each material. Samples were processed as described above for the laboratory trials and analyzed by culture and QPCR.
|
|
|---|
![]() |
|
View this table: [in a new window] |
TABLE 1. Concentrations of E. herbicola cell suspensions used to inoculate triplicate sections of test materials evaluated in laboratory studies, as determined by culture and QPCR analysis
|
|
View this table: [in a new window] |
TABLE 2. Efficiency of surface sampling methods for detection of E. herbicola in laboratory studiesa
|
![]() View larger version (20K): [in a new window] |
FIG. 2. Summary of QPCR results obtained from surface samples in the experimental room. Materials were contaminated by aerosolization of E. herbicola into the room, followed by settling of the bioaerosol onto surfaces in the room. Duplicate surface samples were collected by sponge (930 cm2 = 1 ft2) and macrofoam swab (317 cm2 = 49 in2) for each of three releases. Bar heights represent the mean of six samples ± 1 standard error.
|
|
|
|---|
The type of surface material sampled also affected the efficiency of recovery of E. herbicola from surfaces. Some differences were observed between laboratory trials using a liquid inoculum and test chamber trials with aerosolization and deposition of cells onto the test materials. In general, the greatest concentrations of E. herbicola were measured on smooth, nonporous materials such as glass and metal. In laboratory trials, the greatest concentrations were obtained in surface samples from glass. In chamber trials, the results obtained from the vertically oriented surface of the computer monitor screens (power on) were lower than all of the other materials except concrete. In contrast, previous experiments with aerosolized dry endospores of the simulant Bacillus atrophaeus showed that surface samples of computer monitor screens had greater concentrations of spores than any of the other materials tested (unpublished data), presumably due to electrostatic attraction of the spores to the surface of the monitor. Because microbial contamination may be present on all types of surfaces, it is important to develop effective sampling methods for both porous and nonporous surfaces and be able to reliably determine the contamination levels on these materials, especially for assessing the efficacy of decontamination efforts.
E. herbicola sampling efficiencies measured by QPCR ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge in laboratory studies for collection of E. herbicola from surfaces, as determined by QPCR analysis. Surface sampling results from test chamber aerosolization trials supported those obtained in laboratory trials. The SW Kit consists of a premoistened macrofoam swab. In a previous study, the collection efficiencies of four types of swabs, cotton, macrofoam, polyester, and rayon, were compared by inoculating steel coupons with known concentrations of B. anthracis spores and surface sampling with both wet and dry swabs (10). Results indicated that premoistened macrofoam and cotton were the swab materials that had the greatest collection efficiency. In this study, collection efficiencies measured for the swab with metal surfaces were comparable to those obtained previously with steel coupons, although the test organisms and analysis methods differed. It is possible that one of the reasons for the lower collection efficiencies obtained with sponge samples was the difference in the collection buffers used. The swab was obtained premoistened with a buffer containing the surfactant Tween 20, while the sponge was wetted with buffer without a surfactant added. Rose et al. suggest that the use of a surfactant in the collection buffer may enhance the collection of spores (10), but thorough buffer evaluation studies have not been conducted. Another possible explanation for the lower collection efficiencies observed with the sponge is that a component of the sponge material had an inhibitory effect on QPCR. In our previous sponge sampling experiments with B. atrophaeus using an internal positive control in the QPCR, inhibition was not observed for any of the materials except concrete. Results indicated that sponge samples from concrete were completely inhibited and swab samples were slightly inhibited (unpublished data). Therefore, the presence of inhibitory compounds associated with concrete likely accounted for the low measurements of E. herbicola obtained with sponge samples. For swabs, less area was sampled and the concentration of inhibitory compounds in the sample was probably lower. In this study, inhibition of the QPCR assay was not determined.
Although the sponge method was less efficient than the swab for surface sampling, their detection sensitivities are similar. The larger surface area sampled by the sponge (930 cm2) resulted in comparable concentrations of E. herbicola in samples for both the swab and the sponge (Table 2). In previous research that measured the collection efficiency and sensitivity of the Biological Sampling Kit, a device designed for large-area surface sampling, results showed that the large surface area (1 m2) sampled by the Biological Sampling Kit resulted in higher sensitivity than the swab sampling methods tested (2). Another potential advantage of large-area sampling in the field is greater coverage that results in fewer samples collected per site. Potential uses for the sponge include intermediate-to-large-area surface sampling, particularly on smooth, nonporous surfaces, whereas swab sampling is most applicable for sampling small areas, nonsmooth surfaces, and locations where access is difficult. Based on the results obtained in this research, the selection of the sample analysis method and the type of surface to sample were more important considerations for maximizing the detection of E. herbicola than the type of sampling method chosen.
The aftermath of the bioterrorism events of 2001 involving B. anthracis spores has emphasized the importance of surface sampling for detection of biological contaminants and the need for additional research to determine the collection efficiencies and sensitivities of surface sampling methods (7, 12, 13). The results of this research provided quantitative data on the collection efficiencies of two surface sampling methods and demonstrated the abilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials. Additional studies designed to minimize environmental interference and optimize sampling and processing methods are ongoing to improve the field applicability of surface sampling for detection of biocontaminants in indoor environments. The protocols developed could be adapted for use in other environmental microbiological applications to enhance the detection and measurement of surface-associated microorganisms.