Previous Article | Next Article ![]()
Applied and Environmental Microbiology, June 2007, p. 4040-4047, Vol. 73, No. 12
0099-2240/07/$08.00+0 doi:10.1128/AEM.00161-07
Copyright © 2007, American Society for Microbiology. All Rights Reserved.

Central Science Laboratory, Sand Hutton, York YO41 1LZ, United Kingdom
Received 22 January 2007/ Accepted 13 April 2007
|
|
|---|
|
|
|---|
The use of nucleic acid-based methods, especially PCR, for the identification and detection of plant pathogens is becoming increasingly widespread (17, 21, 37). In particular, real-time PCR methods have the advantages of speed, accuracy, and sensitivity over other methods (7, 28, 30, 43) and can be closed-tube systems involving no postamplification steps. TaqMan (11, 16) is the most widely used real-time PCR system, and assays using this detection chemistry have been described for a range of plant pathogens (3, 4, 14, 39, 38, 40), including assays for the detection of Phytophthora ramorum both in the laboratory (8, 12, 34) and in the field (33). A single round of real-time PCR has been found to be sufficiently sensitive to achieve the detection of 10 to 100 fg P. ramorum DNA in plant material (8, 33). However, nested PCR has been used to improve the sensitivity of detection in some matrices (8). These assays may have a number of limitations which could restrict their use in the field. For instance, many TaqMan assays use standard thermal cycling conditions, but even a rapid cycling real-time PCR instrument such as the Smart Cycler II (Cepheid, Sunnyvale, CA) takes over an hour to complete 40 cycles of standard TaqMan thermal cycling (33). This amount of time may be prohibitive when carrying out testing in the field. The use of rapid cycling instruments to perform real-time PCR in very short periods of time has been described previously (1), but increasing the speed of thermal cycling has been reported to have a detrimental effect on the sensitivity and reproducibility of some real-time PCR assays (10). Despite this effect, a reduction in the absolute sensitivity of an assay may be an acceptable compromise in circumstances where a faster result would be particularly advantageous, provided that the material to be tested is likely to contain levels of pathogen significantly in excess of the assay's limit of detection. Other real-time PCR systems commonly in use are reported to have potential advantages over TaqMan (43). In particular, scorpion primers (42), which act by a unimolecular mechanism, can be used with fast thermal cycling conditions to allow a result to be obtained in a much shorter period of time (32).
Another potential limitation of existing assays for P. ramorum is specificity. Previously described assays for P. ramorum designed within the internal transcribed spacer 1 (ITS 1) region of the nuclear ribosomal DNA have shown cross-reactions with high concentrations of DNA extracted from Phytophthora lateralis (9, 33), which differs from P. ramorum by only 11 bp in the ITS region (9). Cross-reactivity has been observed at only high DNA concentrations (more than 1 ng P. lateralis DNA in the PCR), and material being tested for P. ramorum is very unlikely to contain P. lateralis (a root pathogen). Improved specificity would allow undiluted extracts from cultures to be tested without the risk of false-positive results. One approach to improving the discrimination of similar species is to design a new assay for a different region of the genome (2, 13, 29). However, modifications to existing assays can also be made to improve specificity without the need to completely redesign the primers and/or probe. For example, the introduction of 3' locked nucleic acid (LNA) residues into PCR primers has been shown to improve specificity in allele-specific PCRs (15). Alternatively, the use of a different real-time PCR detection chemistry could result in greater specificity. It has been reported that molecular beacons (35) can offer improved specificity over systems such as TaqMan, in which the probe does not contain a hairpin structure (36).
Despite the numerous advantages of real-time PCR over conventional PCR and other nucleic acid-based detection methods, such techniques may not be ideal for use in the field due to the complexity (and expense) of the equipment required. Loop-mediated isothermal amplification (LAMP) is a method which uses a set of four or six primers and the strand displacement activity of Bst DNA polymerase to amplify DNA with high specificity under isothermal conditions in less than 1 h (22, 23, 24). LAMP products can be visualized by gel electrophoresis, by measuring the increased turbidity (due to the production of large amounts of magnesium pyrophosphate) either in real time or at the end of the reaction (19, 20), or by using fluorescent intercalating dyes (6, 25). The simplicity of methods such as LAMP, which do not require thermal cycling, makes them well suited to field testing and potentially valuable to laboratories without real-time PCR facilities.
This paper describes modifications to a previously described TaqMan assay for P. ramorum and the development of alternative assays (scorpion, molecular beacon, and LAMP) designed using the same ITS target sequence in order to increase the feasibility of nucleic acid-based testing in the field. The relative advantages and disadvantages of each assay are considered.
|
|
|---|
Real-time PCR primers and probes.
P. ramorum-specific primers (Pram-114F and Pram-190R) and a TaqMan probe (Pram probe), designed based on the ITS sequence of a range of Phytophthora spp. as previously described (12), were used as the basis for the design of a duplex scorpion primer, molecular beacon, and alternative reverse primer (Pram-199R) (Fig. 1). Primer and probe sequences, modifications, and reporter/quencher dyes are shown in Table 1. The duplex scorpion consists of two oligonucleotides: the scorpion primer itself, composed of a primer sequence attached to the reverse complement of a probe sequence (42), and a separate quencher oligonucleotide (31) which is complementary to the probe segment (Fig. 1 and Table 1). The molecular beacon is composed of a probe sequence flanked by complementary arm sequences, giving a stem-loop structure. A second reverse primer was designed to accommodate the molecular beacon sequence (Fig. 1). Six LAMP primers (external primers F3 and B3, internal primers FIP and BIP, and loop primers F-Loop and B-Loop) were designed in the same region (Fig. 2) (for details of the principle of the LAMP method, see the work of Notomi et al. [24]). TaqMan primers and probe and LAMP primers were synthesized by MWG Biotech (Ebersberg, Germany), and the duplex scorpion primer and molecular beacon were synthesized by Eurogentec (Seraing, Belgium). TaqMan primers containing LNA bases were synthesized by Sigma Proligo (Boulder, CO).
![]() View larger version (13K): [in a new window] |
FIG. 1. Primer and probe design for TaqMan, scorpion, and molecular beacon assays. Sequence differences between P. ramorum and P. lateralis are underlined. The positions of the LNA bases in the primers used for the LNA TaqMan are shown in bold. Sequence accession numbers are AY785958 for P. ramorum and AY785952 for P. lateralis.
|
|
View this table: [in a new window] |
TABLE 1. Characteristics of primers and probes used for real-time PCRa
|
![]() View larger version (12K): [in a new window] |
FIG. 2. Primer design for LAMP assay. Sequence differences between P. ramorum and P. lateralis are shown in bold. Internal primer FIP is composed of the complementary sequence to F1 plus the sequence F2; internal primer BIP is composed of the sequence B1 plus the complementary sequence to B2. The P. ramorum sequence accession number is AY785958.
|
Real-time PCR results were analyzed in terms of threshold cycle (CT) value (the PCR cycle at which background-corrected fluorescence exceeds the threshold value). The default threshold setting (30 fluorescent units) was used throughout.
Loop-mediated isothermal amplification.
DNA extract (1 µl) was added to 24 µl of master mix, and negative controls containing nuclease-free water instead of DNA were included in each run. LAMP master mix consisted of 0.32 U/µl Bst DNA polymerase (New England Biolabs, Ipswich, MA), 1x ThermoPol buffer, 1.4 mM each dNTP, 6 mM MgCl2 (including 2 mM in Thermopol buffer), 1.2 M betaine, 200 nM each external primer (F3 and B3), 2 µM each internal primer (FIP and BIP), and 1 µM each loop primer (F-Loop and B-Loop). Reactions were incubated at 65°C for 40 min and then at 80°C for 5 min to inactivate the Bst polymerase. Amplified products were visualized by gel electrophoresis or by adding 2 µl Quant-iT PicoGreen double-stranded DNA (dsDNA) reagent (Invitrogen, Carlsbad, CA) and observing the color change (from orange to yellow). For real-time monitoring of LAMP reactions, EvaGreen dye (Biotium, Hayward, CA) (20x concentration in phosphate-buffered saline) was added to give a final concentration of 0.5x, and the reaction mixtures were held at 65°C for 40 min on the Smart Cycler, with a fluorescence reading every 60 s. Real-time LAMP results were analyzed in terms of Tp (time to a positive result) values using the default threshold setting as for real-time PCR.
|
|
|---|
![]() View larger version (16K): [in a new window] |
FIG. 3. Standard curves of CT values for serial dilutions of P. ramorum DNA. CT values are mean values for duplicate reactions; error bars show standard deviations. (A) TaqMan real-time PCR. (B) TaqMan real-time PCR with LNA reverse primer. (C) Scorpion real-time PCR. (D) Molecular beacon real-time PCR.
|
|
View this table: [in a new window] |
TABLE 2. Phytophthora sp. isolates used for specificity testing
|
P. ramorum scorpion assay.
Amplification of P. ramorum DNA by scorpion real-time PCR was initially carried out using a range of concentrations of MgCl2 (3.5 to 5.5 mM), dNTPs (0.1 to 0.4 mM), Pram scorpion (300 to 600 nM), Pram-190R reverse primer (400 to 800 nM), ThermoPrime Plus DNA polymerase (0.02 to 0.08 U/µl), and bovine serum albumin (0 to 500 ng/µl), plus different scorpion-to-quencher ratios (1:1 to 1:10) and annealing/fluorescence monitoring temperatures (50 to 65°C, with separate or combined annealing and fluorescence-monitoring steps), in order to optimize the reaction conditions. Optimal conditions were selected on the basis of the lowest CT value and/or the highest fluorescence signal. A dilution series of DNA extracted from P. ramorum culture was tested using the optimized scorpion assay in order to characterize its sensitivity and efficiency (Fig. 3C). The response of the assay was linear down to 500 fg, and the estimated efficiency of amplification was 0.90. The lowest amount of P. ramorum DNA reliably amplified within 40 cycles was 500 fg. None of the other Phytophthora species tested, including P. lateralis (70 ng DNA), were amplified by the scorpion assay within 40 cycles.
P. ramorum molecular beacon assay.
Amplification of P. ramorum DNA by molecular beacon real-time PCR was initially carried out using a range of concentrations of MgCl2 (4 to 6 mM), dNTPs (0.1 to 0.4 mM), Pram molecular beacon (50 to 300 nM), Pram-114F forward primer (50 to 900 nM), Pram-199R reverse primer (50 to 900 nM), and Hot Taq DNA polymerase (0.025 to 0.1 U/µl), plus a range of annealing temperatures (45 to 60°C) and different thermal cycling conditions (with or without a separate extension step at 72°C) in order to optimize the reaction conditions. Optimal conditions were selected on the basis of the lowest CT value and/or highest fluorescence signal. A dilution series of DNA extracted from P. ramorum culture was tested using the molecular beacon assay in order to characterize its sensitivity and efficiency (Fig. 3D). The response of the assay was linear down to 500 fg, and the efficiency of amplification was 0.94. Of the other 28 species of Phytophthora tested, P. lateralis was amplified with a mean CT value of 36.24, and Phytophthora cactorum was amplified with a CT value of 39.30. A mean CT value of 38.83 was obtained for a second isolate of P. cactorum (isolate reference MUCL9638; Belgian Co-ordinated Collections of Micro-organisms). A dilution series of DNA extracted from P. lateralis culture was also tested using the molecular beacon assay, and the lowest amount of DNA detected was 7 ng (mean CT value of 39.83).
P. ramorum LAMP assay.
Optimization of the P. ramorum LAMP assay was carried out using gel electrophoresis to visualize the LAMP products. A range of concentrations of MgSO4 (2 to 8 mM), dNTPs (0.2 to 2 mM), primers (0.2 to 2 µM), betaine (0.8 to 1.6 M), and Bst DNA polymerase (0.32 to 0.64 U/µl), plus different incubation times (10 to 90 min), were used in order to optimize the reaction conditions. Optimal conditions were selected on the basis of the amount of product as assessed by gel electrophoresis (suboptimal conditions often resulted in no amplification) and also on the basis of cross-reactivity with P. lateralis DNA. A dilution series of P. ramorum DNA was tested using an incubation period of 40 min (Fig. 4A). Fifty picograms of P. ramorum DNA was consistently amplified, and 10 pg was amplified in one out of two replicate reactions, indicating that 10 pg is close to the limit of detection for this assay. PicoGreen dsDNA reagent also was added to the LAMP reaction tubes, and the color change from orange to yellow was observed to indicate a positive reaction. The PicoGreen results were consistent with the gel electrophoresis results (Fig. 5). In order to characterize the LAMP assay further, LAMP reactions were also run on the Smart Cycler with a fluorescent intercalating dye (EvaGreen) added to the reaction mix to allow amplification to be monitored in real time (Fig. 6A). A linear relationship between DNA concentration and Tp value was observed (Fig. 6B). In the real-time assay, there was an unambiguous distinction between positive reactions (amplification plots for 10 ng to 10 pg DNA) and negative reactions (1 pg DNA, water) after 40 min.
![]() View larger version (43K): [in a new window] |
FIG. 4. LAMP. (A) A dilution series of P. ramorum DNA was amplified by LAMP, and the product was visualized by gel electrophoresis. M, marker; lane 1, negative control (water); lanes 2 and 3, 10 ng P. ramorum DNA; lanes 4 and 5, 1 ng P. ramorum DNA; lanes 6 and 7, 100 pg P. ramorum DNA; lanes 8 and 9, 50 pg P. ramorum DNA; lanes 10 and 11, 10 pg P. ramorum DNA; lanes 12 and 13, 1 pg P. ramorum DNA. (B) Cross-reactivity of LAMP assay with P. lateralis DNA. M, marker; lane 1, negative control (water); lane 2, positive control (10 ng, P. ramorum DNA); lanes 3 and 4, 70 ng P. lateralis DNA; lanes 5 and 6, 7 ng P. lateralis DNA; lanes 7 and 8, 700 pg P. lateralis DNA.
|
![]() View larger version (132K): [in a new window] |
FIG. 5. LAMP products visualized by adding 2 µl PicoGreen dsDNA reagent at the end of the reaction. The presence of a large amount of LAMP product in positive reaction mixtures causes a color change from orange to yellow. The results shown are for the same reaction mixtures as in Fig. 4A. The amount of Phytophthora ramorum DNA added to each reaction mixture is indicated for each tube.
|
![]() View larger version (25K): [in a new window] |
FIG. 6. Real-time monitoring of LAMP reactions. (A) Amplification plots for LAMP amplification of a dilution series of P. ramorum DNA. (B) Standard curve of mean Tp values. Tp values are mean values for duplicate reactions; error bars show standard deviations.
|
Speed of assays.
Since the Smart Cycler software displays results in real time, it is possible to obtain a positive result before the run is completed. TaqMan real-time PCR was carried out using modified cycling conditions in order to determine how much the time taken to detect P. ramorum DNA (approximately 10 ng) could be reduced without making any other modifications: mean CT values are shown in Table 3. The time taken to achieve a positive result was reduced from 39 min using standard cycling conditions to 30 min using a denaturation time of 5 s and an annealing/extension time of 30 s. This reduction in time was accompanied by an increase in CT value from 19.37 to 24.03. Further reductions of the annealing/extension period caused a greater increase in CT value, with the effect that the time taken to obtain a positive result was not reduced below 30 min (Table 3). A dilution series of P. ramorum DNA was tested using a denaturation time of 5 s and an annealing/extension time of 30 s, and a standard curve was constructed (R2 = 0.9865). The efficiency of amplification was reduced from 0.92 using standard cycling conditions to 0.65 (data not shown). The run times and time to result for the different real-time PCR assays were also compared. The Smart Cycler run times for the optimized TaqMan, molecular beacon, and scorpion assays were 70 min, 80 min, and 27 min, respectively. The time taken to detect 10 ng P. ramorum DNA was approximately 39 min for the TaqMan assay, 45 min for the molecular beacon assay, and 14 min for the scorpion assay (Fig. 7). A DNA extract from a rhododendron leaf sample containing 0.1% symptomatic P. ramorum-inoculated leaf by weight (containing approximately 10 pg P. ramorum DNA per µl) was also tested using each real-time PCR assay. The time taken to obtain a positive result was approximately 57 min for the TaqMan assay (mean CT value of 31.27), 65 min for the molecular beacon assay (mean CT value of 31.68), and 22 min for the scorpion assay (mean CT value of 32.54). A positive LAMP result for this extract was obtained in 45 min using PicoGreen detection.
|
View this table: [in a new window] |
TABLE 3. Effect of changing TaqMan real-time PCR cycling conditions on CT values for the detection of P. ramorum DNAa
|
![]() View larger version (17K): [in a new window] |
FIG. 7. Speed of real-time PCR assays. Amplification plots showing fluorescence versus time in minutes for the detection of 10 ng P. ramorum DNA using TaqMan, molecular beacon, and scorpion real-time PCR.
|
|
|
|---|
Other potential obstacles to the use of the P. ramorum TaqMan assay in the field are the expense and complexity of the portable equipment required to perform simultaneous thermal cycling and fluorescence monitoring. However, alternative approaches, such as serological or morphological methods, can have significant disadvantages of speed, sensitivity, and specificity which limit their use in the field. Isothermal amplification of a specific DNA sequence by LAMP combined sensitivity and specificity (approaching the performance of real-time PCR methods) with requirements for only basic equipment (a water bath or heated block) and endpoint detection using a color-change reaction visible with the naked eye. The LAMP assay was found to be somewhat less sensitive than the real-time PCR assays tested but was still able to detect P. ramorum in plant material containing a low level of the pathogen. LAMP has the potential to be used in the field by nonspecialists (for example, to carry out surveillance at ports of entry or in the nursery industry) and also in small or regional laboratories in which nucleic acid-based testing is not currently performed and equipment is limited. Methods have been described for monitoring LAMP reactions in real-time using the increase in turbidity which accompanies amplification (19, 20) or using fluorescent intercalating dyes (6, 25). While the use of real-time monitoring may be very useful for characterizing assays during development and optimization, the main advantage of LAMP over real-time PCR is the ability to perform reactions without the need for any specialized equipment. The use of a simple color change detection method is particularly well suited for use in the field, and the extremely high product yield and amplification efficiency of the LAMP reaction ensure that results obtained with this method of detection are unambiguous. However, the very high yield of the LAMP reaction could also be a significant disadvantage of this method. PicoGreen dsDNA reagent completely inhibits the LAMP reaction at the concentration needed to produce a color change visible with the naked eye. However, opening the tube after the reaction has finished in order to add the PicoGreen reagent makes the method extremely vulnerable to carryover contamination due to the very large amount of product generated. Possible methods for closed-tube endpoint detection have been suggested (18). The results of some initial experiments using either a compartmentalized reaction tube (26) or a reaction tube with PicoGreen dried onto the lid (to keep the PicoGreen separate from the reaction mix until after amplification) have been promising (data not shown).
The assays described in this paper are all designed within the same target sequence in the ITS 1 region of the nuclear ribosomal DNA; however, it has been reported that assays based on other genes, including ß-tubulin and elicitin (2), or on mitochondrial genes (cox I and cox II) (34) may have greater sensitivities and/or specificities than ITS-based assays. In particular, it has been reported that assays designed in regions other than ITS may distinguish between P. ramorum and P. lateralis more reliably. We have found that the specificity of the P. ramorum TaqMan assay can be improved by the introduction of an LNA base in one of the primers, without the need to design new primers and probe in a different region and without any significant adverse effect on sensitivity or efficiency. This modification has the major advantage that only one reagent needs to be replaced, reducing the cost of implementing this change and avoiding the need for reoptimization. The scorpion PCR assay also failed to amplify levels of P. lateralis DNA that were amplified by standard TaqMan PCR. The ability of the assays described in this paper to discriminate P. lateralis from P. ramorum was determined using DNA concentrations in excess of the levels likely to be encountered in the field and also somewhat higher than the extracts used to characterize the specificities of real-time PCR assays for P. ramorum in the past (8, 34). It has been reported that greater specificity can be exhibited from molecular beacons than from other probe types which do not have hairpin structures (36). While our molecular beacon assay had a sensitivity level similar to that of the original TaqMan assay, we did not observe any improvement in specificity; in fact, the molecular beacon assay was the only assay tested that amplified P. cactorum DNA.
A particular advantage of the original TaqMan assay is that it has been optimized for use in multiplex with an internal control assay for the detection of DNA from the host plant. The development of suitable internal control assays to be used with the assays described here will be extremely important for the interpretation of results, as will thorough validation of the methods in comparison with established methods. It also should be emphasized that in order to perform nucleic acid-based detection methods in the field it is crucial to have suitable nucleic acid extraction methods which can be performed with minimal equipment in the shortest possible amount of time. The DNA extraction method described previously for P. ramorum detection in the field (33) can be completed in approximately 40 to 50 min and requires only a heated block and a PickPen hand-held magnetic separation device (Bio-Nobile, Turku, Finland). This methodology could be used in conjunction with, for example, the scorpion real-time PCR assay to obtain results within 1 h of sample collection or with the LAMP assay to allow detection using only extremely basic equipment. However, this extraction method has a number of disadvantages, such as the small sample size that can be processed and the relatively low efficiency of extraction compared to those of established laboratory protocols. The development of more versatile DNA extraction methods which are even more rapid and simple to perform will be the next step in realizing the potential for performing nucleic acid-based testing for plant pathogens in the field.
Published ahead of print on 20 April 2007. ![]()
|
|
|---|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»