Previous Article | Next Article ![]()
Applied and Environmental Microbiology, August 2007, p. 5104-5110, Vol. 73, No. 16
0099-2240/07/$08.00+0 doi:10.1128/AEM.00450-07
Copyright © 2007, American Society for Microbiology. All Rights Reserved.

Quality & Safety Assurance Department, Nestlé Research Center, Lausanne, Switzerland,1 Quality Management Department, Nestlé Product Technology Center, Orbe, Switzerland,2 Nestlé Waters, Vittel, France3
Received 27 February 2007/ Accepted 14 June 2007
|
|
|---|
|
|
|---|
Although there is no epidemiological evidence that bottled water serves as a vehicle for viral diseases, some doubts were raised concerning its safety due to the reported finding of NV sequences in 33% of commercially available water samples sold in Switzerland (2, 3). However, attempts by other research groups to reproduce these results were always in vain (6, 15, 16, 19, 21, 27), even though much larger numbers of samples and more-sensitive detection methods were used. Further investigations strongly suggested that the original findings were due to artifacts and systematic mistakes (21). Since these unfounded allegations could have severe economic consequences for the bottled water industry, it is essential to develop internationally accepted virus detection methods for this matrix. An essential step in the validation of such methods is the organization of a collaborative trial to demonstrate its reproducibility. When preparing artificially contaminated samples for the validation of our NV detection method in bottled water based on membrane filtration and real-time reverse transcription-PCR (RT-PCR) (16), we observed a substantial decrease of the viral load after a few days of storage. Since adsorption of human enteric viruses to the walls of different container materials had been reported previously (7, 8, 20, 25, 28), we suspected that a similar phenomenon was occurring in our samples. We therefore investigated whether enteric viruses may also adsorb to polyethylene terephthalate (PET) and glass bottles and to what extent such adsorption depends on the virus strain, the chemical composition of the water, and the presence of autochthonous microorganisms. After developing an efficient elution protocol, we also undertook a survey of 294 commercially available water bottles obtained from 25 different countries.
|
|
|---|
The cytopathogenic HM-175 strain of HAV (courtesy of A. Bosch, Enteric Virus Group, University of Barcelona, Spain) and the simian RV strain SA-11 were propagated and assayed in FRhK-4 and MA-104 cell monolayers, respectively. Semipurified stocks were produced with the same cells by low-speed centrifugations of infected cell lysates. Infectious virus enumerations were performed by determining the 50% tissue culture infectious dose (TCID50) with eight wells per dilution and 20 µl of inoculum per well.
Bottled waters.
Locally purchased bottled waters with different mineral compositions were used during this study (Table 1).
|
View this table: [in a new window] |
TABLE 1. Mineral composition of bottled water brands used in this study
|
HAV RNA was quantified by using a LightCycler HAV quantification kit (Roche Diagnostics, Mannheim, Germany) with a LightCycler instrument as described previously (5, 22). Briefly, a total of 2.5 µl of extracted RNA was transferred into a capillary containing 7.5 µl of Master Mix. RT was performed at 55°C for 10 min, and amplification was performed for 1 cycle of 95°C for 30 s and 45 cycles of 95°C for 5 s, 55°C for 15 s, and 72°C for 12 s. The LightCycler HAV quantification kit contains internal HAV RNA standards that allow the number of RNA copies per sample to be estimated.
RV real-time RT-PCR was based on a previous publication (23) with some modifications and was adapted to the LightCycler instrument (Roche Diagnostics). Briefly, real-time RT-PCR was performed using a QuantiTect SYBR Green RT-PCR kit (QIAGEN) consisting of 10 µl QuantiTect SYBR Green, 0.2 µl QuantiTect RT mix, 0.625 µM (each) P1 and P2 primers, and 0.8 U of RNase inhibitor (Promega). Five microliters of RNA was denaturated by heating for 5 min at 95°C and transferred into a capillary containing 15 µl of Master Mix. RT was performed at 50°C for 30 min; amplification was performed for 1 cycle of 95°C for 15 min and 50 cycles of 94°C for 30 s, 58°C for 60 s, 72°C for 1 min, and 75°C for 5 s. The data were collected in the single mode during the 75°C segment. A melting curve analysis was performed (segment 1 [95°C for 5 s; slope, 20°C/s; acquisition mode, none], segment 2 [65°C for 5 s; slope, 20°C/s; acquisition mode, none] and segment 3 [95°C for 0 s; slope, 0.1°C/s; acquisition mode, continuous]). A RV standard curve was generated by performing real-time RT-PCR with 10-fold dilutions of strain SA-11-extracted RNA. The crossing points obtained from the assay of each dilution were used to plot a standard curve by assigning the corresponding TCID50 values.
Analysis of inoculated water samples.
Three liters of bottled and deionized water were inoculated with ca. 2.4 x 106 PCRU of NV, 1.5 x 105 TCID50 of HAV, or 3.3 x 103 TCID50 of RV. Inoculated samples were gently mixed and distributed over nine bottles. Batches of three bottles were analyzed at days 0 (immediately after inoculation), 20, and 62. Samples were stored undisturbed in the dark at room temperature.
Water samples were analyzed as described elsewhere (9, 16). Briefly, after the bottles were shaken vigorously, the water was filtered through a 0.45-µm-pore-size positively charged membrane (Zetapor filter membrane; CUNO, Inc., Meriden, CT). Virus particles were further concentrated by ultrafiltration (Amicon centrifugal filter device, 100K NMWL; Millipore, Molsheim, France) followed by RNA isolation using a commercially available kit (QIAamp viral RNA mini kit; QIAGEN). RNA extracts were either analyzed immediately by real-time RT-PCR or stored at –80°C until use. Nucleic acid suspensions were analyzed in duplicate by the specific real-time RT-PCR method, which also allowed us to estimate the number of recovered viruses or RNA copies.
Empty bottles were filled with 10 ml of elution buffer (50 mM glycine, 1% [wt/vol] beef extract [BD Difco beef extract paste; Becton Dickinson AG]; pH 9.5). Attached viruses were released from the bottle by vigorous shaking (Turbula T10B shaker mixer; Willy A. Bachofen AG) for 20 min at room temperature. The elution buffer was then transferred into a tube, and empty bottles were rinsed with 2 ml of elution buffer. The recovered elution buffer was then adjusted to pH 8.0 ± 0.2 with 1 M HCl, transferred to an Amicon Ultra-15 centrifugal filter device (100K NMWL; Millipore), and centrifuged at 4,000 rpm to concentrate the virus particles. The eluate was adjusted to 140 µl with phosphate-buffered saline, and RNA extraction was performed using a QIAamp viral RNA mini kit (QIAGEN) according to the manufacturer's instructions (Fig. 1A).
![]() View larger version (10K): [in a new window] |
FIG. 1. Flow chart of the method. Method A uses independent analysis of water and wall phases, whereas methods B and C analyze them as a single sample. l, liter; EB, elution buffer.
|
Effect of autochthonous flora on adsorption.
The autochthonous flora of bottled water was not characterized, but the influence of this flora was studied by comparing virus adsorptions for filter-sterilized water with those for non-filter-sterilized water. Three liters of bottled water brand 3 and deionized water were sterilized through a 0.22-µm-pore-size filter (Millipore) and then inoculated with ca. 2.4 x 106 PCRU of NV, 1.5 x 105 TCID50 of HAV, or 3. 3 x 103 TCID50 of RV. Inoculated samples were gently mixed and distributed over nine bottles (330 ml PET). Batches of three bottles were analyzed at days 0 (immediately after inoculation), 20, and 62. Samples were stored undisturbed in the dark at room temperature and analyzed as described above.
Analysis of commercially bottled water samples.
A simplified protocol for analyzing simultaneously the water phase and the packaging material was developed (Fig. 1B and C). The initial steps for water and bottle wall analysis were identical to those described above. Once viruses were released from positively charged membrane and bottle walls, elution buffers were pooled and further concentrated using a centrifugal filter device (100K NMWL) adapted to the volume required. The eluate was adjusted to 200 µl with phosphate-buffered saline, and then RNA extraction was performed by using a Magna Pure Compact Robot (Roche Diagnostics), applying the "DNA_Blood_100_400" protocol according to the manufacturer's instructions. Viral RNAs were detected using real-time RT-PCR for HAV and RV and by RT-PCR for generic NV detection as described elsewhere (16). The presence of inhibitors was monitored by using the internal control supplied with the HAV kit. For NV detection, RNA samples were analyzed twice, once without and once with the addition of a positive NV RNA sequence.
|
|
|---|
Exposure to ultrasound reduced the NV recovery to less than 0.1% and was therefore not included in the standard protocol.
NV adsorption in different types of bottled waters.
NV adsorption onto the bottle wall (PET and glass bottles) was evaluated after 0, 20, and 62 days using five different bottled water brands and deionized water. To investigate viral adhesion to PET or glass bottles, the percentages of the recovered genome present in the aqueous phase and adhering to walls were monitored at days 0, 20, and 62. In PET bottles, NV retention on the bottle walls after 20 days reached an average level of approximately 75% of the total recovered inoculum versus only 2.5% at day 0. Viral adsorption rose to 91% after 62 days of storage. No significant differences between the five types of bottled waters were observed, whereas in deionized water, virus adsorption to the bottle wall was limited to only 35% after 62 days of storage (Fig. 2).
![]() View larger version (13K): [in a new window] |
FIG. 2. NV adsorption on PET bottles at days 0, 20, and 62. Percentages of virus recovery from the water and the wall (the amount of viruses recovered from the wall or the water divided by the total amount of recovered viruses) are depicted in white and gray, respectively. Error bars represent standard deviations (n = 3). Numbers depicted on the x axis correspond to the bottled water brands. H2Od, deionized water.
|
![]() View larger version (14K): [in a new window] |
FIG. 3. NV adsorption on glass bottles at days 0, 20, and 62. Virus recovery (the amount of viruses recovered from the wall or the water divided by the total amount of recovered viruses) from the water and the wall are depicted in white and gray, respectively. Error bars represent standard deviations (n = 3). Numbers depicted in the x axis correspond to the bottled water brands. H2Od, deionized water.
|
![]() View larger version (20K): [in a new window] |
FIG. 4. HAV adsorption onto PET bottles at days 0, 20, and 62. Comparison between bottled water and filter-sterilized water. Percentages of virus recovery (the amount of viruses recovered from the wall or the water divided by the total amount of recovered viruses) from the water and the wall are depicted in white and gray, respectively. Lines represent the total viral titer recovered ( ), viral titer recovered in water ( ), and viral titer recovered in walls ( ) expressed as RNA copies. (A) Bottled water. (B) Deionized water. Error bars represent standard deviations (n = 3).
|
![]() View larger version (18K): [in a new window] |
FIG. 5. RV adsorption on PET bottles and titer at days 0, 20, and 62. Comparison between bottled water and filter-sterilized water. Percentages of virus recovery (the amount of viruses recovered from the wall or the water divided by the total amount of recovered viruses) from the water and the wall are depicted in white and gray, respectively. Lines represent the total viral titer recovered, expressed as the TCID50. (A) Bottled water. (B) Deionized water. Error bars represent standard deviations (n = 3).
|
![]() View larger version (18K): [in a new window] |
FIG. 6. NV adsorption on PET bottles and titer at days 0, 20, and 62. Comparison between bottled water and filter-sterilized water. Percentages of virus recovery (the amount of viruses recovered from the wall or the water divided by the total amount of recovered viruses) from the water and the wall are depicted in white and gray, respectively. Lines represent the total viral titer recovered, expressed in PCRU. (A) Bottled water. (B) Deionized water. Error bars represent standard deviations (n = 3).
|
Kinetics of virus titer recovery.
The total recovered virus titer from the aqueous phase and bottle walls was estimated using the corresponding standard curve at days 0, 20, and 62. NV (PCRU) and RV (TCID50) titers were quite stable in bottled water (18% and 38% titer loss for NV and RV, respectively), whereas ca. 95% and 83% decreases were observed with deionized water after 62 days of storage (Fig. 5 and 6). In contrast, the total HAV titer, surprisingly, increased with the storage time, 3 and 15 times in nonsterilized and filter-sterilized bottled water, respectively, after 62 days of storage (Fig. 4A). To elucidate this trend, the HAV titer was plotted separately in water and wall phases (Fig. 4), showing that the virus titer increase was observed only for the walls. At day 0, HAV was distributed equally on the bottle walls and in the water phase, but on day 20, the majority of genome was found adsorbed onto the bottle walls, with more than two times greater amounts than those found at day 0 in the aqueous phase. At day 62, the genome adhering to walls was more than 4 and 20 times that initially found in the aqueous phase for nonsterilized and filter-sterilized bottled water, respectively. To ascertain whether this titer increase was due to a technical problem, the efficiency of the water filtration protocol (inoculated viruses/recovered viruses in the water phase at day 0) was determined for the three viruses and was determined to be only 1% for HAV (instead of the ca. 30% and 10% obtained for NV and RV, respectively), suggesting that the HAV titer in water was underestimated; as soon as HAV was adsorbed to bottle walls, the efficiency of recovery was much better.
Analysis of bottled water samples.
In the framework of verifying the safety of bottled water, a worldwide survey of 294 commercial bottled water samples of different origins was carried out (Table 2). All tested bottled water samples were found to be negative for the presence of NV, HAV, and RV genomes in the aqueous phase and on bottle walls. The presence of RT-PCR inhibitors was evaluated for all brands of bottled waters included in this survey for NV and HAV. The HAV internal control was detected in all the tested samples, as was the NV RNA added to the RNA extracts. These results suggest that inhibitors did not play a role in this study.
|
View this table: [in a new window] |
TABLE 2. Results for finished bottled water samples investigated during the virus survey
|
|
|
|---|
From a method standardization point of view, virus adsorption onto bottles is undesirable, because it makes it more difficult to prepare stable reference samples that can be used for collaborative trials. However, our results also showed that viruses can also be desorbed from the bottle wall by rinsing the bottles with a small amount of elution buffer. By combining this elution procedure with the normal concentration procedure for virus detection, the total amounts of NV and RV recovered from the bottles were fairly stable (less than 38% loss over 62 days). It is therefore recommended that this combined protocol be used for collaborative studies to facilitate comparisons of the results.
NV adsorption onto glass bottles was also detected, but more time was needed to reach the same adsorption level as that measured for PET bottles. NV adsorption may be influenced by the mineral composition of the water, since water brand 5, with the lowest content of Mg2+, Ca2+, and Na+ ions, and deionized water showed the lowest degrees of adsorption onto glass and PET bottles.
It is noteworthy that virus attachment using 0.22-µm-pore-size-filtered bottled water showed different patterns depending on the virus. NV was detected mainly in the water phase of filter-sterilized bottled water after 62 days of storage, whereas only 1% was found in the water phase if the bottled water contained its own autochthonous flora. For RV, these percentages were 50% and 3.5% for nonsterilized and filter-sterilized bottled water, respectively, whereas for HAV, 2.7% and 9.5% were recovered. In a recent publication on poliovirus adsorption to hydrophobic tubes (7), it was reported that the autochthonous flora did not appear to have any influence. Differences in adsorption depending on the viral species have also been described for adsorption to soils (ranging from 0 to 99%) and lettuce and have been attributed to the variability of the capsid, which influences the net charge on the virus (11, 26). Assuming no role for the autochthonous flora, the HAV attachment may be explained by the isoelectric point of the viral capsid, affecting the electrostatic potential between virus and bottle and enhancing the affinity of viruses for the walls. This assumption is supported by the fact that even at day 0, half of the HAV titer, in nonsterilized and filter-sterilized bottled water, was found attached to the bottle walls.
It is well known that many bacteria are able to establish a biofilm on the bottle walls (13, 14), and it may well be that NV and RV adsorb more readily to the biofilm than to the bottle itself. A second hypothesis, suggested also for virus interaction with clay (18), may involve some bacterial components that may reduce the electrostatic repulsive forces between the viruses and the PET bottle, thereby permitting the viruses to approach the PET surface sufficiently for adsorption to occur by cation exchange, hydrogen bonding, van der Waals forces, or hydrophobic interactions (17, 24).
Many studies conducted on the survival of enteric viruses in water indicated that the loss of virus titer occurs at a variety of rates (1, 4, 7, 10, 12, 29). However, in several of these studies, loss of viruses due to adherence to the support was not considered. Under our experimental conditions, the total viral genome remained quite stable over the analyzed period of time in bottled water (nonsterilized and filter-sterilized), with the exception of HAV, where the titer increase was due to the better performance of the procedure to release virus adsorbed to walls than the water filtration method.
It is debatable whether bottle analysis should also be used for monitoring purposes. Once the viruses are adsorbed, they are no longer of concern for the consumer, and it therefore seems pointless to try to detect them. However, one can argue that if an adsorbed virus were found, it would be an indication that the water source is contaminated and that viruses were present in the water phase at some point. From this perspective, it would be better to utilize the combined protocol, because a negative result with this method would be more meaningful than a negative result obtained with a method that does not detect adsorbed viruses. For this reason, we performed a survey of 294 samples of bottled water which were obtained from 25 different countries using the combined protocol. Since all samples tested negative for NV GI, NV GII, HAV, and RV, it is concluded that the corresponding sources were not contaminated with these viruses. These results, together with the absence of epidemiological data linking the consumption of bottled water to viral outbreaks, strongly support the theory that bottled water is not a vehicle for viral infections.
Published ahead of print on 22 June 2007. ![]()
|
|
|---|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»