Previous Article | Next Article ![]()
Applied and Environmental Microbiology, November 2007, p. 7380-7387, Vol. 73, No. 22
0099-2240/07/$08.00+0 doi:10.1128/AEM.00687-07
Copyright © 2007, American Society for Microbiology. All Rights Reserved.

and
Dennis J. Lye2
U.S. Environmental Protection Agency, Office of Water, Technical Support Center, Cincinnati, Ohio 45268,1 U.S. Environmental Protection Agency, Office of Research and Development, National Exposure Research Laboratories, Cincinnati, Ohio 452682
Received 26 March 2007/ Accepted 17 September 2007
|
|
|---|
|
|
|---|
Transmission by drinking water has been suggested as the explanation for a fecal-oral bacterial route, and the presence of H. pylori DNA in drinking water systems has been reported from the United States, England, Germany, Japan, Sweden, Mexico, Gambia, and Peru (4, 8, 23-27, 31, 42). Using a combined fluorescent antibody 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) staining method, Hegarty et al. also demonstrated the presence of respiring H. pylori cells from U.S. surface waters (20). Only one report of live H. pylori isolated and cultured from untreated municipal wastewater has been published (30). However, several laboratory studies have demonstrated that H. pylori can survive in water under a variety of conditions for a period of days to weeks (3, 40, 44). One reason for the inability to culture the bacteria from water could be that the bacterium changes from the normal spiral-shaped bacillary form into the coccoid form when it is exposed to water or to other adverse conditions (2, 6, 10, 12). This coccoid form has been shown to be capable of oxidative metabolism and respiration (13, 19) and has been shown to possess DNA and mRNA, albeit in diminished amounts (34). Whether the coccoid form is viable/infectious is a subject of debate. It has not been possible to resuscitate the coccoid cells and restore their normal morphological state or to grow them in the laboratory, although the spiral form can be grown under suitable culture conditions (6, 40, 44). It has been proposed that the morphological change into the coccoid form is a transitory adaptation to environmental stress for the species to survive and thus may play a role in its survival in and transmission through water. Therefore, it has become necessary to detect H. pylori in this state. In the absence of a culture medium, the current nucleic acid-based methods seem to be the only methods available for detecting H. pylori in water.
Several regular PCR assays are available for H. pylori detection in environmental water (4, 18, 25, 29, 36, 39, 43), with detection sensitivities ranging from 2 to 100 cells per reaction reported by some investigators. Some of these reports have used primer sets that may detect other Helicobacter species. None of these studies presents results in a quantitative manner. The use of quantitative PCR has been reported by Horiuchi et al., who used the 16S rRNA as the target (23), and by McDaniels et al., who used a conserved region from the ureA gene, which is specific for H. pylori (32) and encodes the urease A subunit of the urease protein. A detection sensitivity of 100 cells/ml was reported by the former study, while 10 cells per liter of water was demonstrated by the latter. Because the number of cells in drinking water may be small, with H. pylori DNA being detected by PCR amplification only after concentration of large volumes of drinking water (21, 28, 39), and because the infectious dose of the organism is not known, it becomes necessary to quantify very low numbers. Both false negatives and false positives may arise due to these conditions. To avoid some of these errors, careful controls must be included in any standardized method. The purpose of this study was to develop internal amplification controls (IC) that could be used with the assay developed by McDaniels et al. (32) by multiple laboratories for method validation studies as well as for occurrence studies. In addition, a DNA extraction method that can reliably sample an entire liter of water has been optimized.
|
|
|---|
Enumeration of H. pylori cells.
H. pylori cell suspensions were counted directly by using a hemocytometer (Hauser Scientific, Horsham, PA) under phase contrast (Eclipse 80i; Nikon, Tokyo, Japan) at a total magnification of x400. At this magnification, both spiral (1 by 2 µm to 1 by 4 µm) and coccoid (1 by 1 µm) forms were visible. Suspensions were typically diluted 1:10 in phosphate-buffered saline before cells were counted. Optical density readings at 640 nm (OD640) were also monitored by a spectrophotometer (MBA 2000; PerkinElmer, Waltham, MA). An OD640 reading of 0.5 corresponded to approximately 9 x 108 cells/ml. The relationship of OD640 to the viable cell count was derived after recording direct microscopic counts and optical density readings at several cell dilutions, with cells obtained from plates incubated for 48 h from different preparations. The correlation between hemocytometer counts and the viable counts was more than 95% (data not shown).
Preparation of DNA from pure cultures and plasmids.
Total genomic DNA from pure cultures of H. pylori was prepared by using a Puregene kit (Gentra, Minneapolis, MN) or a WaterMaster kit (Epicentre Biotechnologies, Madison, WI). The protocols were followed as specified by the manufacturers. DNA was extracted in a final volume of 50 µl of Tris-Cl, pH 8. DNA concentration was measured using a NanoDrop ND-1000 UV-Vis spectrophotometer (NanoDrop Technologies, Wilmington, DE) sample adjusted with water to a final concentration of 20 ng/µl water, and 5 µl was used in 25 µl for PCR. Plasmid DNA was prepared using a Qiagen Plasmid Mini kit according to the instructions of the manufacturer (Qiagen Corp., Santa Clarita, CA).
Construction of IC.
A DNA molecule to be used as the IC, corresponding to the amplicon generated by primers HpyF1 and HpyR1 from the H. pylori Texas strain, was made as follows. A PCR amplicon of 135 bp was first generated with primers HpyF1 and HpyR1, using genomic DNA from the H. pylori Texas strain as the target. The sequences of the two oligonucleotides, HpyF1 (5'-GGGTATTGAAGCGATGTTTCCT-3') and HpyR1 (5'-GCTTTTTTGCCTTCGTTGATAGT-3'), have been described previously (32). This 135-bp fragment was used as the template in two touchdown PCRs (at 65°C to 55°C). In one reaction mixture, the primers HpyF1 and BamH1-F1 were used to generate a 53-bp fragment, and in the other reaction mixture, the primers HpyR1 and BamHI-R1 were used to generate an 89-bp fragment. The sequence of the BamHI-F1 primer was 5'-GGATCCCACGGTTACGAGTT-3', and the BamHI-R1 primer sequence was 5'-GGATCCCCTATTGAGGCCAA. Both of the primers had a BamHI site incorporated at the 5' end. The two fragments were gel purified from a 3% agarose gel, using a QIAquick gel extraction kit (Qiagen Corp., Santa Clarita, CA), digested with the restriction enzyme BamHI (Invitrogen, Inc.), cleaned up using a Qiagen PCR purification kit (Qiagen Corp., Santa Clarita, CA), and ligated overnight using T4 DNA ligase (Invitrogen, Inc.). Following ligation, 6 µl of the ligation product was amplified using the HpyF1 and HpyR1 primers. The 135-bp fragment, which should have a new BamHI site incorporated into it, was blunt ended and ligated into a pCC1 vector (8,138 bp), using a copy control cDNA, gene, and PCR cloning kit, and transformed into chemically competent TransforMax EP1300 Escherichia coli, per the instructions of the manufacturer (Epicenter Biotechnologies, Madison, WI). Plasmid DNA from E. coli clones was purified using a QIAprep spin miniprep kit (catalog no. 27104; Qiagen Corp., Santa Clarita, CA.) and sequenced by the core facility of the Children's Hospital Medical Center, Cincinnati, OH. Sequence comparisons were made using BioEdit software (Ibis Therapeutics, Carlsbad, CA).
Optimization of DNA extraction from water.
H. pylori cells were spiked in 1 liter of distilled water. All spiked samples were first filtered through a Nuclepore polycarbonate filter, 47 mm in diameter, with a pore size of 0.45 µm (Whatman, Clifton, NJ). In initial experiments, both 0.45-µm- and 0.2-µm-pore-size filters were examined. No significant differences were observed between the two filters in terms of retention or recovery of either the spiral or the coccoid form of the H. pylori cell, but the flow rate was faster through 0.45-µm filters. It was decided to continue with these filters. Eight methods were examined to determine the most efficient method for the recovery of DNA from the polycarbonate filters. The DNA isolation methods examined included the use of a Puregene DNA isolation kit, a cell and tissue kit (Gentra, Minneapolis, MI), a WaterMaster DNA purification kit with and without inhibitor removal (Epicentre Biotechnologies, Madison, WI), an Ultraclean soil DNA kit (Mo Bio Laboratories, Inc, Carlsbad, CA), a DNA-EZ kit (GeneRight, LLC, New Brunswick, NJ), a DNA-EZ kit with a Qiagen purification column (GeneRight, LLC/Qiagen), and a bead-beating method with 0.3 g of glass beads in 0.1x AE buffer (Qiagen proprietary buffer containing 0.2 µg/ml salmon sperm DNA for 1 min), and a method that combined bead milling and a QIAamp microkit (Qiagen Corp., Santa Clarita, CA).
Protocols according to the manufacturers' instructions were followed with some modifications for some kits. Specifically, all kits that required an isopropanol precipitation of DNA and an ethanol wash were modified to use ice-cold isopropanol and ethanol, and all final resuspension volumes were changed to 30 to 35 µl. An Ultraclean soil DNA kit method was performed according to the manufacturer's alternative protocol in order to obtain maximum yields. A modified DNA-EZ kit was used to capture DNA from the entire lysate, and buffer volumes were scaled up appropriately. A DNA-EZ kit was also tested by substituting a Qiagen purification column for the column provided by GeneRight. The combination bead milling/QIAamp kit method used 0.3 g of glass beads, 300 µl of ATL buffer, 300 µl of AL buffer, and 40 µl of proteinase K for bead milling (Qiagen Corp., Santa Clarita, CA). All lysates were transferred to a QIAamp MinElute column, and procedures were carried out using a QIAamp DNA microkit protocol. A WaterMaster kit was used with and without inhibitor removal. Instead of using a 50-ml conical tube for washing the filter, the filter was placed in a sterile petri dish with the surface that had trapped bacteria facing upward. Washes with 600 µl of tissue and cell lysis buffer were collected in a single 2-ml microcentrifuge tube, and all further procedures were done in 2-ml tubes. This eliminated dividing the sample into two tubes of 1. 5 ml each and later pooling the final DNA solutions, as suggested by the manufacturer.
Contamination occurred consistently while testing with a DNA-EZ kit. Specifically, H. pylori was detected in negative controls (for both columns) with a cycle threshold (CT) value that was sometimes as low as 35.7, which amounts to about 50 cells. The Puregene kit was less sensitive, detecting 400 cells (CT = 40.7). Bead milling in combination with a QIAamp microkit detected 5 cells (CT = 41.7). However, the CT values over multiple cell concentrations varied greatly, suggesting that this method was inconsistent. A Mo Bio kit detected 25 cells (CT = 40.0), and the basic bead milling detected 57 cells (CT = 38.5). Unlike other kits, WaterMaster with or without inhibitor removal consistently detected 10 cells (CT = 38.7) and maintained a strong correlation between CT value and cell concentration. For this reason, a WaterMaster kit without the inhibitor removal step was used for further experiments for drinking water, where there is unlikely to be large interferences from the matrix.
Once the kit was optimized, water samples were spiked with either E. coli KS10 cells or cells from the H. pylori Texas strain or with both strains simultaneously. Typically the E. coli strain was grown overnight in Luria-Bertani (LB) broth containing 12.5 µg chloramphenicol/ml. The next morning, this culture was used to inoculate 3 ml of fresh broth containing 12.5 µg/ml of chloramphenicol prepared from an ethanolic stock solution of 25 mg/ml. Cells were allowed to grow for 2 h, at the end of which a reading at OD640 was taken. Using the relationship OD640 of 0.5 equaled 2.5 x 108 cells, the cells were diluted in distilled water so that 105 cells/ml, 104 cells/ml, and 103 cells/ml were obtained, giving concentrations of 1,000, 100, and 10 cells, respectively, in 10 µl of each of these dilutions. Typically, 1-liter water samples were spiked with 10 cells of E. coli as the matrix spike. A 10-µl aliquot was also plated on chloramphenicol agar plates, and the plates were incubated overnight at 37°C to obtain the actual number of cells added. After being spiked with the desired number of H. pylori cells, each of the samples was filtered, and the DNA was extracted by using a WaterMaster kit. DNA was extracted in a final volume of 33 µl of water, and 11 µl was used for each 25-µl PCR. A duplicate PCR was run for each sample, and if the CT values were similar (standard deviation of
1), then the third aliquot was not run. With 14 µl being used up for reagents, a maximum volume of 11 µl could be used as the template, and this volume was used to get the best sensitivity in the 25-µl PCR. The number of cells used for generating the data points was therefore taken as one-third of the total cells added (e.g., 33.33 for 100 cells; 3.3 for 10).
Fast PCR.
Fast PCR was used to generate fragments for the preparation of IC. The maximum reaction mixture volume for the instrument (30 µl) was used to maximize products for cloning purposes. It contained 15 µl of 2x Gene Amp Fast PCR mixture (Applied Biosystems, Foster City, CA), 5 µl of template DNA, and primers at a final concentration of 1 µM. Reactions were performed in an ABI 9800 Fast Thermal Cycler (Applied Biosystems, Foster City, CA), and the reaction time was 45 min for touchdown PCR, used to generate the individual fragments, and 20 min for regular PCR, used to generate the initial amplicon and the final amplicon, using the HpyF1 and HpyRI primers. The cycling conditions for touchdown PCR were as follows: an initial single cycle at 95°C for 10 s, followed by five cycles of three-temperature cycling at 95°C for 0 s, 65°C for 0 s, and 72°C for 20 s, followed by 21 cycles of three-temperature cycling at 95°C for 0 s, 65°C for 0 s, and 72°C for 20 s, with the annealing temperature of 65°C incrementally decreased by 0.5°C in subsequent cycles from the initial 65°C to 55°C, followed by 15 cycles of three-temperature cycling at 95°C for 0 s, 55°C for 0 s, and 72°C for 20 s and a final single cycle at 72°C for 5 min. Regular PCR was performed using the default parameters of the instrument and consisted of the following steps: an initial single cycle at 95°C for 10 s, followed by 30 cycles of two-temperature cycling at 94°C for 0 s and 64°C for 15 s, followed by a final cycle at 72°C for 10 s.
TaqMan assay.
The duplex PCR was performed in 25-µl volumes in 0.2-ml optical-grade PCR tubes (Applied Biosystems, Foster City, CA). Each 25 µl of reaction mixture contained 1 µl of probe and primer mixture, 0.5 µl of 5% bovine serum albumin, and 12.5 µl of TaqMan Universal Master mixture, which is a 2x proprietary mixture containing AmpliTaq Gold DNA polymerase, AmpErase uracil N-glycosylase (UNG), amounts of each deoxynucleoside triphosphate (dNTPs) with dUTP, the passive reference dye ROX, and optimized buffer components (Applied Biosystems, Foster City, CA). The master mixture was used without any modification. The final primer concentration in the mixture was 1 µM (for each primer) and 40 nM for each of the probes. The probe that recognized the H. pylori ureA gene, TaqMan probe 1, was labeled with 6-FAM (6-carboxyfluorescein) at the 5'end and with TAMRA (6 carboxytetramethylrhodamine) at the 3' end (5'-FAM-CTCGTAACCGTGCATACCCCTATTGAG-TAMRA3'). TaqMan probe 2, which recognized the modified fragment, was labeled with VIC dye (Applied Biosystems proprietary dye) at the 5' end (5'-VIC-CTCGTAACCGTGGGATCCCCTATTGAG-TAMRA-3'). Both of the probes were made by Applied Biosystems (Foster City, CA). The volume of template used was 11 µl. Depending on the experiment, the template consisted of purified genomic DNA, plasmid DNA, or whole-cell suspensions in water. The copy number calculations were determined as previously described, with the size of the H. pylori genome taken at 1,700 kb and the plasmid pKS10 (vector, 8.139 kb plus an insert of 0.135 kb) at 8.274 kb (38). Thus, 1 fg of genomic DNA amounted to 0.54 copies, while 1 fg of plasmid amounted to 110 copies. The standard cycling condition consisted of an initial single cycle at 95°C for 10 min to activate the AmpliTaq Gold, followed by 50 cycles of two-temperature cycling consisting of 15 s at 95°C and 1 min at 60°C. PCR was performed with an ABI Prism 7000 sequence detection system (Applied Biosystems, Foster city, CA) per instructions provided in the instrument's manual. The CT baseline value was set at 0.06, and the number of cycles run was 45. The numbers were arrived at empirically after performing multiple repeats of the assay over a period of days.
Chlorine measurements.
One-liter water samples were collected from four different distribution systems located in Ohio and in Kentucky. Total chlorine was measured using a Hach Free-and-Total chlorine pocket colorimeter (Hach, Co., Loveland, CO) by the N,N-diethyl-p-phenylenediamine procedure for chlorine measurements (14). The water sample was divided into two aliquots of 0.5 liters each, and Na-thiosulfate was added to a final concentration of 0.1% to 1%. Each aliquot was spiked with 100 cells of H. pylori and 10 cells of E. coli.
Statistical analyses.
The precision of CT measurements for cell, plasmid, or genomic DNA standards was expressed as a percent coefficient of variation (%CV; the standard deviation was expressed as a percentage of the mean). Analysis of covariance tests were performed using Statistical Analysis Software (SAS/STAT User's Guide version 6.4, SAS Institute, Inc., Cary, NC) with procedures PROC MIXED and PROC GLM.
|
|
|---|
![]() View larger version (12K): [in a new window] |
FIG. 1. Sequence of the modified fragment of 135 bp of the IC and the target sequence. The italicized sequences are the primer binding sites for HPYF1 and HPYR1, as labeled. The underlined sequence is the region where the target amplicon has been modified. The sequences in bold are the probe binding sites for the target (FAM probe) and the modified fragment (VIC probe).
|
![]() View larger version (12K): [in a new window] |
FIG. 2. Comparison of different molecules for the standard curve. Standard curves were generated by 10 serial dilutions of genomic DNA, internal control plasmid pKS10 DNA, or H. pylori (HP) cells, each containing one copy of the ureA gene or its modified form, analyzed with an ABI 7000 system. Each 25 µl of PCR mixture, containing 11 µl of DNA or whole cells, was tested in a single-plex reaction using either the FAM probe (genome and whole cells) or the VIC probe (plasmid). The regression lines calculated for each set of data points are shown, in order from top to bottom, pKS10, H. pylori genome, H. pylori cells, and water spike of H. pylori. The standard deviations of the data points are denoted in the graph and range from ±0.08 to ±0.97.
|
PCR efficiency and recovery efficiency of H. pylori DNA from water.
In order to get an accurate estimate of the target molecules in the water sample, other control molecules are needed: controls to test the efficiency of the PCR itself (PCR positive control) and controls for the effect of the water matrix, such as for natural organic matter, minerals, and other inhibitory compounds, on the recovery of DNA from the H. pylori cells, as well as on the PCR. With each new PCR batch, plasmid pKS10 DNA at 1,000 copies was added directly to a tube containing PCR master mixture. A CT value of 31.9 was routinely obtained. This served as the PCR positive control.
Plasmid pKS10 has been cloned in E. coli EP1300. These cells can be added directly to the water sample, and the DNA recovered can be used to determine the matrix inhibitory effects. Before E. coli cells can be used as a surrogate for H. pylori, however, it must be determined whether E. coli can be recovered from water as well as H. pylori. The recovery of both of these organisms from water was efficient, using a WaterMaster kit (Fig. 3), and the regression lines of H. pylori, y = 40.31 – 3.43x (R2 = 0.93; average %CV = 1. 68) and E. coli, y = 40.83 – 3.99x (R2 = 0.91; average %CV = 1.32) had slopes that were not significantly different (P = 0.5275). The results demonstrate that the recovery of H. pylori was not different from that of E. coli cells. The recovery was
100% compared to a standard curve generated by plasmid pKS10, where one copy of plasmid is equivalent to one copy of the ureA gene.
![]() View larger version (17K): [in a new window] |
FIG. 3. Comparison of recovery of H. pylori (HP) and E. coli KS10 cells from water. Standard curves were generated with DNA recovered from water that was spiked with H. pylori cells or E. coli KS10 cells at the concentrations shown in the figure. H. pylori DNA was evaluated with the FAM dye, while E. coli KS10 was evaluated with the VIC dye, in single-plex TaqMan PCR. A standard curve obtained from different concentrations of plasmid pKS10 (VIC probe) was also plotted in parallel (R value). Data points are averages of samples from three different experiments.
|
20 cells of E. coli KS10 (36.7, 36.7, and 36.2 [Table 1]). When the ratio of H. pylori to E. coli cells was 5:30, the CT value of H. pylori shifted from 36.7 to 38.12; at 10:30, the CT value shifted from 35.7 to 37.7 (a relative shift of 1.4 and 2, respectively [Table 1], with a fluorescence signal obtained most of the time); and at a ratio of 30:300, the CT value shifted from 34.3 to 36.7 (a 2.4 relative shift, with a distorted signal). Ten and five cells of H. pylori could not be detected in the presence of 300 cells of E. coli. In order to get a finer titration at the lower limits of detection, different concentrations of E. coli KS10, ranging from 10 to 1,000 cells, were added to 20 cells of H. pylori (Table 2 and Fig. 4B). In the presence of up to 50 cells of E. coli, 20 cells of H. pylori cells could be detected, after which the CT value began to shift toward 40 and the fluorescence signal became distorted.
![]() View larger version (15K): [in a new window] |
FIG. 4. Detection of H. pylori in the presence of IC. (A) To different amounts of H. pylori cells (5 to 3,000 cells), either 10 ( ), 20 ( ), 30 ( ), or 300 (x) E. coli KS10 cells were added. The curve denoted by a was generated with no E. coli cells added. No trend line was added to data points generated with 30 and 300 cells. (B) To 20 cells of H. pylori, 0, 10, 20, 30, 40, 50, 100, 300, or 1,000 E. coli KS10 cells were added. The CT value obtained for each data point is shown in Table 1 for panel A and in Table 2 for panel B.
|
|
View this table: [in a new window] |
TABLE 1. Coamplification of E. coli cells containing IC and H. pylori ureAa
|
|
View this table: [in a new window] |
TABLE 2. Coamplification of 20 H. pylori cells in the presence of E. coli cells with ICa
|
|
View this table: [in a new window] |
TABLE 3. Comparison between DNA detection in the presence and absence of chlorine residue
|
|
|
|---|
Positive controls are necessary to verify if the method is adequately amplifying the target to its limits of detection and if false negatives are absent. Such controls need to be used at several stages in the method: (i) as a matrix spike to test the degree of inhibition from the matrix, if any, and thus give an estimate of the efficiency of nucleic acid extraction from the sample; (ii) as a PCR inhibitor control to test whether the PCR part of the reaction is performing optimally, thus indicating that all the reagents have been added correctly; and (iii) as a method control to determine if the reagents as well as the instruments are performing optimally. One or more kinds of internal controls can be used in the method (37). Such controls can be exogenously added. When naked DNA is being used as an exogenous positive control, it can be used only to test the efficiency of the downstream part of the method, e.g., the PCR. However, if the DNA is incorporated into a surrogate organism, then it can be used as a matrix spike, and the efficiency of the whole method for the particular matrix can be determined. In the method proposed, it was decided to use a modified DNA fragment as the PCR-positive control and a whole organism, an E. coli strain, into which the modified form of the amplicon that is detected in the H. pylori target was cloned, as a matrix spike. Since the modified DNA in the plasmid is quantified similarly to the H. pylori genomic target, the DNA structure surrounding the target does not appear to affect the PCR amplification efficiency. This molecule was used as the PCR-positive control in a single-plex assay with each PCR run. The use of a VIC dye-labeled-modified fragment as a positive control can also eliminate contamination issues, which can result in false positives that may arise due to the detection of the positive control in a negative field sample if H. pylori DNA was used.
H. pylori is difficult to grow in the laboratory and may not easily lend itself to interlaboratory validation. Although plasmids have been found in H. pylori and used in H. pylori mutagenesis, it is not clear whether recombinant plasmids can be routinely maintained in the organism and used as necessary (5, 21). A well-defined bacterial system was needed that would routinely produce a single-copy plasmid. Because E. coli can be detected using the DNA extraction system of a WaterMaster kit at the same level of sensitivity as for H. pylori, E. coli may be an adequate surrogate for H. pylori. The use of a modified form of the target amplicon that had a change in the probe region allowed for the use of the same set of primers but with a differentially labeled probe. Thus, unnecessary competition arising from the use of two sets of primers was avoided. A second advantage is the elimination of the need to collect and extract DNA from duplicate samples because this approach allows one sample to be used for both the control and the target detections simultaneously, with the use of two fluorescent dyes in a multiplex PCR. This approach also reduces the chances of variability that may arise from comparing two different aliquots, albeit from the same water source. Initially, the modified form of the target was cloned into a multicopy plasmid. However, the addition of a few cells of E. coli containing this plasmid shifted the CT value of low numbers of H. pylori cells beyond the limits of detection. This unexpected result can be explained by the fact that in an actively dividing standard E. coli cell, a multicopy plasmid can reach up to 100 copies per cell (41). Thus, the addition of 10 cells of this strain amounted to having 1,000 copies of the modified target. Since it is likely that if H. pylori was present in water it would be at low levels, the modified ureA fragment was inserted into a single-copy plasmid that would allow the detection of 10 copies from 10 cells. The copy control vector pCC1, which contains both the E. coli F factor-based single-copy origin of replication and the high-copy oriV origin of replication, proved to be convenient for this since it could be produced in a single copy in EP1300 cells (Epicentre Biotechnologies) or, when induced by an induction solution, produced in multiple copies. The latter was used for generating large amounts of plasmid to be used as standard molecules. Cloning the fragment in a single-copy plasmid provided an additional amount of quality control by keeping cross-contamination due to IC to a minimum.
After carefully titrating the number of copies of the internal control to be used in the PCR so that the target could still be detected within the limits of detection, it was decided to keep the internal control at 10 to 20 cells. At this level, there would be little competition with even as low as five cells of H. pylori. Although there is the risk of suppressing the signal with the VIC probe from using the IC at 10 to 20 cells, if greater than 300 cells of H. pylori cells are present in the field sample, it would not lead to a false-negative result. In such an event, the positive result generated from the H. pylori DNA by the FAM signal would be taken as valid because the IC amplification becomes unnecessary (22). The use of IC at a high concentration may also lead to nondetection of low-grade inhibition from the matrix, which in turn may lead to nondetection of a low number of target samples (35).
Many of the current methods described in the literature do not sample the entire liter of sample collected (23, 32, 42). In this method, we examined several commercial DNA extraction kits. A WaterMaster kit allowed us to test the entire liter of sample with greater than 95% recovery of cells. An unexpected observation was that more copies of the ureA gene from H. pylori cells were obtained than that predicted from the number of cells spiked. Since the cells were derived from 48-h plates of H. pylori (where
99% of the cells are in the spiral form), the cells may be in the process of DNA replication and cell division, resulting in an increase in the copy number of some of the genes of the cells without impacting the turbidity of the media or the microscopic counts. The cells present in the water distribution system are likely to be in the coccoid form. This form has been shown to be a viable but unculturable form, with diminished DNA (1, 28). The effectiveness of a WaterMaster kit in extracting the DNA from these cells and the subsequent detection by qPCR does not seem to be different from that for the spiral cells (unpublished results). Thus, the standard curve generated with the purified plasmid can be used to estimate the copy number in the field sample.
When water samples were collected from different distribution systems and spiked with a fixed number of H. pylori cells, the presence of residual chlorine seemed to have affected the observed CT value. It is known that chlorine and chlorine-releasing agents bind directly to the DNA, forming chlorinated derivatives of nucleotide bases, which has a deleterious effect on the growth of bacteria (16, 17). In one study, at a concentration of 2.6 mg/liter (50 µM), hypochlorous acid completely inhibited the growth of E. coli and DNA synthesis by 96% within 5 min (33). The binding of chlorine to the DNA may have resulted in increased CT values. Another explanation could be that the chlorine residue interfered with the fluorescence signal of the qPCR. A change in fluorescence intensities of E. coli cells containing enhanced green fluorescent protein on exposure to active chlorine has been reported by Burnett and Beuchat (9). Additional work is needed to clarify the effect of chlorine in qPCR assays. Other components in the water matrix might also have an affect on the CT values. In any case, water samples from distribution systems should be collected in the presence of a chlorine-neutralizing agent such as 0.1% sodium thiosulfate.
In conclusion, the method described in this study, which uses a specific internal standard as a positive control and a new method of sample preparation, could form the basis for an accurate and robust screening tool for the detection of H. pylori DNA in water at levels as low as 5 to 10 cells/liter of water.
Published ahead of print on 28 September 2007. ![]()
Present address: Dynamac Corporation, U.S. EPA National Exposure Research Laboratory, 26 West Martin Luther King Drive, Cincinnati, OH 45268-0001. ![]()
|
|
|---|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»