Previous Article | Next Article 
Applied and Environmental Microbiology, April 2007, p. 2338-2340, Vol. 73, No. 7
0099-2240/07/$08.00+0 doi:10.1128/AEM.01758-06
Copyright © 2007, American Society for Microbiology. All Rights Reserved.
Comparison of a Reporter Assay and Immunomagnetic Separation Real-Time Reverse Transcription-PCR for the Detection of Enteroviruses in Seeded Environmental Water Samples
,
Yu-Chen Hwang,1
Oymon M. Leong,1
Wilfred Chen,2 and
Marylynn V. Yates1*
Department of Environmental Sciences,1
Department of Chemical and Environmental Engineering, University of California, Riverside, California2
Received 25 July 2006/
Accepted 21 January 2007

ABSTRACT
Two newly developed protocols for infective virus detection
were compared to the plaque assay. An immunomagnetic separation
procedure coupled with real-time reverse transcription-PCR of
viral nucleic acids was developed to identify intact enteroviral
particles, and a reporter cell system responding to viral replication
based on fluorescent resonance energy transfer for detection
of infectious enteroviruses was tested. Both new procedures
detected infective viruses in environmental samples at the same
level as the plaque assay.

INTRODUCTION
In the United States, for regulatory purposes involving analysis
of water (for example, drinking water sources) the total culturable
virus assay is required for detection and enumeration of viruses.
However, cell culture assays are expensive, labor-intensive,
and time-consuming. Thus, simpler, more rapid detection methods
based on detection of nucleic acids, such as PCR or reverse
transcription-PCR (RT-PCR), are attractive. However, the results
of methods based solely on PCR or RT-PCR often do not correlate
with infectivity, as the presence of a viral genome does not
necessarily indicate the presence of infectious viral particles,
and thus these results are potentially false-positive results
(
9,
10). In addition, the need to concentrate large volumes
(hundreds to thousands of liters) of water prior to analysis
often results in accumulation of substances that inhibit PCR,
which can cause false-negative results (
5). Various techniques,
such as immunomagnetic separation (IMS), have been proposed
to avoid PCR inhibition (
5,
7).
A protocol using IMS combined with a molecular beacon was developed previously (11). Magnetic beads (Dynabeads M-280 sheep anti-mouse immunoglobulin G; Dynal Biotech, Norway) coated with mouse anti-enterovirus monoclonal antibody (DakoCytomation, Denmark) were used to purify intact enteroviral particles, and the RNA genomes were analyzed by molecular beacon-based real-time RT-PCR to determine virus concentrations. A universal primer set (forward primer 5'-TCCTCCGGCCCCTGAATGCG-3' and reverse primer 5'-ATGTCACCATAAGCAGCCA-3') along with a molecular beacon probe was designed to target the conserved regions in the 5' untranslated region in human enteroviruses (see the supplemental material). The probe (5'-CGAGCGGCGGAACCGACTACTTTGGGCGCTCG-3'; stem sequences underlined) was labeled with a fluorescent dye, 6-carboxyfluorescein, at the 5' end and with a quencher, 4-(4'-dimethylaminophenylazo)benzoic acid, at the 3' end. In order to assess the specificity of the IMS real-time RT-PCR, seven human enteroviruses were tested in duplicate. All enteroviruses were detected with a sensitivity of 1 PFU (average cycle threshold value, 38), while tests for adenovirus 2 (AdV2), AdV15, and hepatitis A virus (HAV) were negative (Table 1).
Another recently developed method (
4), in which a genetically
engineered reporter cell line is used for detection of infectious
viruses based on fluorescence resonance energy transfer (FRET),
was tested. This reporter assay was performed as described previously
(
4). Briefly, cells were cultured in 16-well slide chambers
to confluence, and monolayers containing approximately 10
5 cells
were infected with viruses as indicated below. Reporter cells
without viruses were used as the negative control. The cells
were challenged with AdV2, AdV15, and HAV (100 or 1,000 PFU)
to test substrate specificity of the 2A protease. Samples were
mounted on glass slides 7.5 h postinfection and examined using
a confocal microscope (Leica TCS SP2/UV). To observe the in
vivo FRET phenomenon, the cells were visualized by fluorescent
microscopy at excitation and emission wavelengths of 440 and
480 nm, respectively, for enhanced cyan fluorescent protein
and at excitation and emission wavelengths of 480 and 520 nm,
respectively, for enhanced yellow fluorescent protein. For microscopic
examination of the infected cells, the well surface was divided
into 20 image-capturing areas; each observation frame contained
approximately 2,500 cells. The cells with an increased enhanced
cyan fluorescent protein signal, indicating active virus replication,
were counted and identified as infectious units. The specificity
of the reporter assay was evaluated by challenging the reporter
cells with the enteroviruses listed in Table
1, and only echovirus
11 (EV11) and poliovirus 1 (PV1) were detected with a detection
limit of 1 PFU due to the high level of conservation in their
2A
pro cleavage sequences.
Surface water from various sites in southern California was used to evaluate the performance of the two protocols. Water concentrates from several localities were pooled and confirmed to be negative for human enteroviruses and HAV by a plaque assay (3, 12). PV1 was added to the concentrate at a concentration of 1, 10, 100, or 1,000 PFU per 1-ml sample; each 1-ml sample was analyzed using IMS RT-PCR, the reporter assay, and the plaque assay in parallel. Dilutions of the PV1 stock were prepared, and the threshold cycles, determined by real-time RT-PCR, were regressed against the corresponding number of PFU, as determined by the plaque assay. Each data point was generated with five independent replications.
The same set of samples was used to evaluate the potential for environmental application of the reporter assay. Numbers of infected reporter cells, determined by microscopy as described above, were regressed against the corresponding number of PFU, as determined by the plaque assay. Each data point was generated from five independent experiments. Both IMS RT-PCR and the reporter assay exhibited a high level of correlation (R2 > 0.9) with the conventional plaque assay, indicating that the two methods performed as well as the plaque assay (Fig. 1), although we cannot state conclusively that the RT-PCR detected only infective particles. Analysis of variance confirmed that there was no significant difference between the three methods tested (P = 0.3982).
Nucleic acid amplification techniques involving RT-PCR have
been used to detect enteroviruses rapidly (
2). Various attempts
to address the issue of infectivity, notably with integrated
cell culture PCR and IMS, have been reported previously (
1,
5,
8). To our knowledge, this is the first report of the development
of an IMS RT-PCR using molecular beacon-based real-time PCR
for the detection of human enteroviruses in environmental water
samples. The IMS procedure using monoclonal antibodies provided
a high degree of sensitivity and specificity (Fig.
1). The anti-enterovirus
monoclonal antibody reacts with most of the enteroviruses; there
is no cross-reaction with adenovirus, rhinovirus, or HAV (
6).
The one-step real-time RT-PCR using a universal primer set and
the molecular beacon probe targeting all enteroviruses is a
simplified procedure with excellent specificity (see the supplemental
material). The IMS RT-PCR assay was designed to target a wide
range of human enteroviruses; it identified all seven enteroviruses
tested with the same sensitivity (Table
1). The reporter assay
was designed for identification of infectious PV1, but it also
responded to viruses with a similar protease cleavage site,
such as EV11 (
4). The reporter assay selectively detected infectious
PV1 and EV11 but not other human enteroviruses tested in this
study (Table
1). To our knowledge, this is the first report
of using FRET for the detection of infectious viruses in environmental
water samples. By taking advantage of the specificity between
the viral protease and its cleavage sequence, it is possible
to tailor a reporter cell line that responds exclusively to
a given viral infection. It should also be possible to design
a reporter cell line responding to all human enteroviruses by
using a consensus linker sequence that is recognized by the
2A protease of all enteroviruses.
Here we describe development of an assay using IMS real-time RT-PCR to detect human enteroviruses. This assay was directly compared with the reporter cell assay and plaque assay for the detection of infectious human enteroviruses. The performance of each of the methods was assessed using concentrated surface water samples, and it was found that the two protocols provided the same detection sensitivity as the conventional plaque assay. The results of this study can be used to assist in making decisions about the method that should be used when information concerning the presence and number of infectious enteroviruses in an environmental sample is needed.

ACKNOWLEDGMENTS
We thank Xinping Cui for her assistance with the statistical
analysis.
Yu-Chen Hwang is a recipient of a U.S. Environmental Protection Agency Greater Research Opportunity fellowship.

FOOTNOTES
* Corresponding author. Mailing address: Department of Environmental Science, University of California, Riverside, CA 92521. Phone: (951) 827-2358. Fax: (951) 827-3993. E-mail:
marylynn.yates{at}ucr.edu.

Published ahead of print on 2 February 2007. 
Supplemental material for this article may be found at http://aem.asm.org/. 

REFERENCES
1 - Abd El Galil, K., M. El Sokkary, S. Kheira, A. Salazar, M. Yates, W. Chen, and A. Mulchandani. 2004. Combined immunomagnetic separation-molecular beacon-reverse transcription-PCR assay for detection of hepatitis A virus from environmental samples. Appl. Environ. Microbiol. 70:4371-4374.[Abstract/Free Full Text]
2 - Corless, C., M. Guiver, R. Borrow, V. Edwards-Jones, A. Fox, E. Kaczmarski, and K. Mutton. 2002. Development and evaluation of a "real-time" RT-PCR for the detection of enteroviruses and parechovirus RNA in CSF and throat swab samples. J. Med. Virol. 67:555-562.[CrossRef][Medline]
3 - Flehmig, B. 1981. Hepatitis A virus in cell culture. II. Growth characteristics of hepatitis A virus in Frhk-4/R cells. Med. Microbiol. Immunol. 170:73-81.[CrossRef][Medline]
4 - Hwang, Y., W. Chen, and M. Yates. 2006. Use of fluorescence resonance energy transfer for rapid detection of enteroviral infection in vivo. Appl. Environ. Microbiol. 72:3710-3715.[Abstract/Free Full Text]
5 - Jothikumar, N., T. Cromeans, V. Hill, X. Lu, M. Sobsey, and D. Erdman. 2005. Quantitative real-time PCR assay for detection of human adenoviruses and identification of serotypes 40 and 41. Appl. Environ. Microbiol. 71:3131-3136.[Abstract/Free Full Text]
6 - Lipson, S., K. David, F. Shaikh, and L. Qian. 2001. Detection of precytopathic effect of enteroviruses in clinical specimens by centrifugation-enhanced antigen detection. J. Clin. Microbiol. 39:2755-2759.[Abstract/Free Full Text]
7 - Myrmel, M., E. Rimstad, and Y. Wasteson. 2000. Immunomagnetic separation of Norwalk-like viruses (genogroup I) in artificially contaminated environmental water samples. Int. J. Food Microbiol. 62:17-26.[CrossRef][Medline]
8 - Olsvik, O., T. Popvic, E. Skjerve, K. Cudjoe, E. Hornes, J. Ugelstad, and M. Uhlen. 1994. Magnetic separation techniques in diagnostic microbiology. Clin. Microbiol. Rev. 7:43-54.[Abstract/Free Full Text]
9 - Schwab, K., R. De Leon, and M. Sobsey. 1995. Concentration and purification of beef extract mock eluates from water samples for the detection of enteroviruses, hepatitis A virus, and Norwalk virus by reverse transcription-PCR. Appl. Environ. Microbiol. 61:531-537.[Abstract]
10 - Skraber, S., B. Gassilloud, L. Schwartzbrod, and C. Gantzer. 2004. Survival of infectious poliovirus-1 in river water compared to the persistence of somatic coliphages, thermotolerant coliforms and poliovirus-1 genome. Water Res. 38:2927-2933.[Medline]
11 - Tyagi, S., and F. Kramer. 1996. Molecular beacons: probes that fluoresce upon hybridization. Nat. Biotechnol. 14:303-308.[CrossRef][Medline]
12 - U.S. Environmental Protection Agency. 1984. Manual of methods for virology. U.S. Environmental Protection Agency publication EPA 600-4-84-013. Government Printing Office, Cincinnati, OH.
Applied and Environmental Microbiology, April 2007, p. 2338-2340, Vol. 73, No. 7
0099-2240/07/$08.00+0 doi:10.1128/AEM.01758-06
Copyright © 2007, American Society for Microbiology. All Rights Reserved.
This article has been cited by other articles:
-
Verheyen, J., Timmen-Wego, M., Laudien, R., Boussaad, I., Sen, S., Koc, A., Uesbeck, A., Mazou, F., Pfister, H.
(2009). Detection of Adenoviruses and Rotaviruses in Drinking Water Sources Used In Rural Areas of Benin, West Africa. Appl. Environ. Microbiol.
75: 2798-2801
[Abstract]
[Full Text]