Previous Article | Next Article ![]()
Applied and Environmental Microbiology, July 2008, p. 4309-4313, Vol. 74, No. 14
0099-2240/08/$08.00+0 doi:10.1128/AEM.00617-08
Copyright © 2008, American Society for Microbiology. All Rights Reserved.

Western Regional Research Center, Agricultural Research Service, U.S. Department of Agriculture, Albany, California 94710
Received 13 March 2008/ Accepted 20 May 2008
|
|
|---|
|
|
|---|
There is a great need to develop better methods to detect active botulinum neurotoxin. The "gold standard" test to detect active botulinum toxin is an in vivo mouse bioassay (6). This procedure, developed in 1927, is still being used by the scientific community. This assay involves the intraperitoneal injection of suspected contaminated food into a mouse and can take 4 to 6 days to obtain results. Because injection of the food product itself or the damage to vital organs during inoculation can cause the mouse's death, the lethal activity must be shown to be neutralized with an antibody against one of the botulinum toxin serotypes (6). This iterative procedure, requiring many animals, is expensive to perform and impractical for testing a large number of samples, and it raises ethical concerns with regard to the use of experimental animals.
Several attempts to replace the mouse bioassay have been made; for example, immunoassays, which speed detection, are useful for testing large numbers of samples (7, 10). However, such immunoassays cannot distinguish between the active form of the toxin, which poses a threat to life, and the inactive form. Also, samples that have tested positive by these immunoassays still require confirmation by the mouse bioassay (6). BoNT activity assays, based on the toxins' ability to cleave specific soluble N-ethylmaleimide-sensitive factor (NSF) attachment protein (SNAP) receptor (SNARE) proteins, have been developed (9). Such cleavage activity has been detected by mass spectrometry (1) and by using fluorescence sensors to detect fluorescence resonance energy transfer (FRET)-based reactions (5). However, such assays are not currently used for food analyses due to interference by peptidases and protease inhibitors in food matrices. The main objective of this study was to develop a rapid in vitro activity assay for the detection of BoNT-A, with a sensitivity level comparable to that of the mouse bioassay. To achieve this objective, we utilized the BoNT-A cleavage activity of SNAP-25, which was detected by FRET assay, and we applied immunomagnetic bead technology to concentrate the toxin from food matrices and to separate it from food peptidases and protease inhibitors.
|
|
|---|
ELISA.
Preparation of enzyme-linked immunosorbent assay (ELISA) was carried out as described previously (12) and as briefly explained. Microtiter plates (NUNC, Rochester NY) were coated with purified BoNT-A (100 µl/well) at concentrations of 400, 200, 100, 50, 25, 12.5, and 6.25 ng/ml in 0.1 M bicarbonate buffer (pH 9.6). Plates were sealed and incubated overnight at 4°C. Plates were then washed three times with Tris-buffered saline (TBS), 50 mM Tris, 150 mM NaCl, titrated to pH 7.6 with HCl. Plates were blocked with 3% skim milk in TBS, 0.05% Tween-20 at 37°C for 2 h (200 µl/well) and washed. Monoclonal antibodies, diluted in TBS and 0.05% Tween-20, were added to the wells (100 µl/well), incubated for 1 h at 37°C, and washed. Anti-BoNT-A, goat anti-mouse immunoglobulin G (IgG), peroxidase-labeled antibody (Sigma) was diluted in blocking buffer and added to the plates. After plates were incubated at 37°C for 60 min, they were washed six times, and 3,3,5,5-tetramethylbenzidine substrate (Sigma) was added (100 µl/well). After 10 min, the reaction was stopped with 0.3 N HCl (100 µl/well), and the plates were read at 450 nm, using a SpectraMax M2 microplate reader (Molecular Devices, Sunnyvale, CA).
Coating beads with IgG.
Dynabeads M-280 (100 µl), tosylactivated or coated with protein G (Invitrogen, Carlsbad, CA), were washed twice with 600 µl of 0.1 M sodium borate buffer (pH 9.5) (catalog no. B-0394; Sigma) and diluted in the same buffer to 2 x 109 beads/ml. Purified anti-BoNT-A antibody (30 µg) was added to 1 x 108 beads (50 µl). The antibody and beads were incubated for 24 h at 37°C on a slow shaker to facilitate covalent binding. The coated beads were washed twice for 5 min at 4°C with 1 ml of phosphate-buffered saline (PBS) (pH 7.4), containing 0.1% bovine serum albumin (BSA), washed once for 4 h at 37°C with 0.2 M Tris-HCl (pH 8.5) containing 0.1% BSA, and washed once more for 5 min at 4°C with PBS (pH 7.4) containing 0.1% BSA. The beads were resuspended in 50 µl of the Tris-BSA buffer.
Assays of BoNT-A or LcA protease activities.
Recombinant toxin light chain stock solution (250 nM) was diluted in 20 mM HEPES and 0.2% Tween-20 (pH 8.2). BoNT-A was diluted to 250 nM in 1 mg/ml BSA and 20 mM HEPES buffer (pH 8.0). Liquid food samples to be spiked with BoNT-A were diluted in sample buffer (20 mM HEPES [pH 8.0], 5 mM dithiothreitol [DTT], 0.3 mM ZnCl2), and 8 µM of the dual-labeled fluorescein substrate was added to the food samples with various concentrations of BoNT-A. Liquid food samples to be spiked with LcA were diluted in 20 mM HEPES and 0.2% Tween-20 (pH 8.2), and 8 µM of the dual-labeled fluorogenic substrate was added to the food samples with various concentrations of LcA. The samples were transferred to a black 96-well plate (Costar-Corning Inc., NY). After incubation at 37°C for various time points, fluorescence emission at 523 nm was measured, with an excitation filter of 490 nm and a cutoff filter of 495 nm, using a SpectraMax M2 microplate reader (Molecular Devices, Sunnyvale, CA).
Preparation of beef sample.
Preserved beef paste (20 g; Gerber) was added to 20 ml of PBS buffer, vortexed, and centrifuged at 1,900 x g for 5 min at 4°C. The supernatant below the layer of fat was transferred to a new tube and spun at 21,000 x g for 5 min. The supernatant was removed and spiked with BoNT-A.
Sample binding.
The immunomagnetic beads (50 µl) were incubated with a tilting motion at 4°C with 40 ml of spiked carrot juice. After samples were incubated for 16 h, the tube was placed on a magnet for 2 min to collect the beads. The beads were washed twice with PBS (pH 7.4) containing 0.1% BSA and resuspended with 1 ml of reduction buffer (20 mM HEPES [pH 8.0], 5 mM DTT, 0.3 mM ZnCl2, and 1 mg/ml BSA). After 8 µM of substrate was added to 1 ml of sample, the tube was incubated at 37°C for 4 h, and then 250 µl of this mixture was transferred to a black 96-well plate. Fluorescence emission at 523 nm was measured, with an excitation filter of 490 nm and a cutoff filter of 495 nm, using a SpectraMax M2 microplate reader (Molecular Devices, Sunnyvale, CA).
Statistical analysis.
Statistical analysis was performed using SigmaStat 3.5 for Windows (Systat Software, San Jose, CA). Multiple comparisons of the spiked food items were made, using several methods. One-way analysis of variance (ANOVA) was used to compare unspiked food with food items that contained increasing concentrations of BoNT-A or LcA. Two-way ANOVA was used to compare various food concentrations with or without the toxin and spiked food items over various time points. The experiments were repeated at least three times, and results with P values of <0.05 were considered statistically significant.
|
|
|---|
![]() View larger version (9K): [in a new window] |
FIG. 1. Direct detection of BoNT-A in carrot juice. Increasing concentrations of BoNT-A (right) or LcA (left) were incubated for 30 min with the internally quenched peptide. Error bars represent standard errors, and an asterisk indicates significant differences (P < 0.05) between carrot juice containing toxin and juice without toxin.
|
![]() View larger version (10K): [in a new window] |
FIG. 2. Assay optimization. Comparison between the MAb-anti light and MAb-anti heavy chain using ELISA (A) or FRET assay (B) showed the MAb-anti heavy has a stronger binding affinity. (C) Comparison of immunomagnetic beads showed that the tosylactivated beads (left) produced a higher signal than the protein G beads (right). RFU, relative fluorescence units.
|
Our results showed that in spiked beef, the peptide cleavage was higher than in beef without the toxin (Fig. 3). During extended incubation, the signal continued to increase, even in beef without the toxin, due to nonspecific cleavage of the peptide by the beef proteases; however, beef containing BoNT-A still showed significantly higher signal than the control.
![]() View larger version (11K): [in a new window] |
FIG. 3. Detection of BoNT-A in beef. Beef was spiked with BoNT-A (150 ng/ml) and incubated for 16 h with tosylactivated beads coated with MAb-anti heavy chain. The beads were washed and incubated with the fluorogenic peptide for 4 h. Significant differences (P < 0.05) are observed between beads incubated with beef containing toxin and beads from beef not containing toxin. Error bars represent standard errors. RFU, relative fluorescence units.
|
![]() View larger version (10K): [in a new window] |
FIG. 4. Limits of detection shown with the bead cleavage assay of 40 ml of carrot juice. Carrot juice was spiked with decreasing concentrations of BoNT-A and incubated for 16 h with tosylactivated beads coated with MAb-anti heavy chain. The beads were washed and incubated with the fluorogenic peptide for 4 h. Error bars represent standard errors, and an asterisk (*) indicates significant differences (P < 0.05) between beads incubated with carrot juice containing toxin and beads from carrot juice not containing toxin. RFU, relative fluorescence units.
|
|
|
|---|
The mouse bioassay determines the subtype of the BoNT by using antibodies specific to each subtype. The contaminated food must be shown to be neutralized by one of the subtypes. Our assay also utilizes antibodies that are specific to each subtype; in addition, we use a synthetic peptide sequence that the toxin recognizes and cleaves at a specific site. Thus, our method of subtyping is more accurate and has less room for error than the method used by the mouse bioassay.
We also compared two different monoclonal antibodies. We utilized monoclonal antibodies because we previously demonstrated that when we employed commercially available polyclonal antibodies that were directed against the entire toxin, including the toxin activity site, these antibodies partially inhibited the enzymatic activity of the toxin and reduced the assay sensitivity.
To optimize the assay, we compared two different types of immunomagnetic beads: tosylactivated beads and beads coated with staphylococcal protein G. The difference between the two immunomagnetic beads is that protein G binds to the Fc domain of the IgG, allowing the Fab fragment to be accessible, whereas tosylactivated beads will bind to some IgG in the wrong orientation, hiding the Fab fragment. We had assumed that the beads coated with protein G would produce better results, because all of the MAb would be in the optimal orientation for efficient toxin binding. However, the tosylactivated beads performed better (Fig. 2C); this may be because the number of IgGs binding to tosylactivated beads was higher than the number of IgGs binding to beads coated with protein G. Thus, the higher number of IgGs on the tosylactivated beads compensated for some of the IgGs that may have been in the incorrect orientation.
Using the immunomagnetic beads offers several advantages; unlike the mouse bioassay, which can only utilize up to 0.5 ml of food matrix, the immunomagnetic beads concentrate the toxin from a large volume, thus increasing the sensitivity of the assay. The toxin, captured by the antibody, is less toxic, allowing for separation of the hazardous phase, which is performed under containment conditions, from the nonhazardous phase, which is used for detection of fluorescence emission. Also, this approach could be readily adapted to the detection of all BoNT serotypes in one reaction by using more than one synthetic peptide with a unique cleavage site labeled with different fluorogenic dyes, to distinguish between the different toxin serotypes. The main advantages of the peptide cleavage assay are that it eliminates animal testing, it offers faster diagnostic testing, and its sensitivity levels are similar to those of the mouse bioassay. Because this peptide cleavage assay does not require the use of animals, the number of laboratories capable of performing BoNT serotype diagnostic assays will increase.
Published ahead of print on 30 May 2008. ![]()
|
|
|---|
This article has been cited by other articles:
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»