Previous Article | Next Article ![]()
Applied and Environmental Microbiology, March 2009, p. 1388-1394, Vol. 75, No. 5
0099-2240/09/$08.00+0 doi:10.1128/AEM.02195-08
Copyright © 2009, American Society for Microbiology. All Rights Reserved.

Center for Advanced Research in Biotechnology, University of Maryland Biotechnology Institute, Rockville, Maryland,1 Center for Advanced Research in Biotechnology/Thomas S. Wootton High School Science Internship Program, Rockville, Maryland,2 9110 Red Branch Road, Columbia, Maryland,3 Animal Biosciences and Biotechnology Laboratory, United States Department of Agriculture, Beltsville, Maryland4
Received 22 September 2008/ Accepted 24 December 2008
|
|
|---|
|
|
|---|
The route of S. equi transmission is through nasal secretions and drainage from abscesses. Infected horses can nasally shed bacteria for weeks, contaminating surfaces through which other horses can become infected. S. equi extract and attenuated-live vaccines exist, but they are often associated with abscess formation at the site of injection, short duration of immunity, poor efficacy, and the very real threat of a nascent infection from the vaccine (15, 24, 29). Thus, strangles continues to be a serious and widespread infectious disease of horses despite the presence of multiple commercially available vaccines.
Strangles prevention strategies include good disinfection/hygiene practices, isolation of infected animals, and removal of equipment for sanitization where possible (9, 26; also R. E. Holland, D. G. Harris, and A. Monge, presented at the 52nd Annual Convention of the American Association of Equine Practitioners, San Antonio, TX, 2 to 6 December 2006). Current broad-spectrum disinfectants belong to one of several chemical categories including alcohols, aldehydes, biguanides, halogens, oxidizing agents, phenols, or quaternary ammonium compounds (6, 8). To various degrees, these compounds have been shown to be flammable, light sensitive, carcinogenic, corrosive to metals, irritating to mucous membranes, and/or toxic to livestock and humans (8, 10). Additionally, many factors that are often associated with cleaning stalls/barns (e.g., hard water, organic load, or detergents) can reduce or even ablate efficacy of chemical disinfectants (8). Importantly, studies have shown that these commonly used disinfectants can select for mutant bacteria with decreased susceptibility to biocides and antibiotics without compromising virulence (21).
Recently, bacteriophage-encoded peptidoglycan hydrolases, collectively termed lysins and often referred to as "enzybiotics," have been investigated as potential therapeutic agents against pathogens due to their ability to lyse the bacterial cell wall (12). These enzymes not only exert their lethal effects in the absence of bacteriophage (cause "lysis from without") but also display specificity for a bacterial host, often for a particular genus, species, or even a subspecies depending on the lysin (11). For example, one lysin, PlyC, is known to lyse streptococcal species bearing a polyrhamnose epitope, which include group C streptococcus (i.e., S. equi subsp. equi) among other streptococci (19). As an adjunct to broad-spectrum disinfectants, we investigate here the use of the PlyC enzyme to help control the acquisition and spread of S. equi subsp. equi in horse stalls and barns.
|
|
|---|
|
View this table: [in a new window] |
TABLE 1. Bacterial strains tested for PlyC sensitivity
|
Spectrophotometric lysis assays.
Bacteria were grown overnight at 37°C, washed in sterile PBS (pH 7.4), and resuspended to the desired concentration as predetermined for each strain based on standard curves of the optical density at 600 nm (OD600) versus the number of CFU. For testing against a panel of bacteria, 100 µl containing 1 x 107 CFU of each organism was mixed with 100 µl of PlyC (1 µg) in a 96-well plate. The OD600 was measured on a SpectraMax 190 instrument (Molecular Devices) every 15 s over a 10-min time period to monitor OD changes that correlated to lysis of the bacteria. Alternatively, 0.2 µg of PlyC was tested in a similar manner against S. equi 9528 (Smr) in the presence of detergents [sodium dodecyl sulfate (SDS), hexadecyltrimethylammonium bromide (CTAB), Tween 20, Triton X-100, 3-[(3-cholamidopropyl)-dimethylammonio]-1-propanesulfonate (CHAPS), or Brij 35] at a final concentration of 1%, EDTA at a 10 mM final concentration, distilled water, fetal bovine serum at final concentrations of 5% and 10%, or synthetic hard water at a calcium equivalent of 400 or 800 ppm. Percent lysis was calculated from endpoint OD600 readings of PlyC buffer controls representing 100% lysis in a 10-min assay. Synthetic hard water was made according to method 960.09 of the Official Methods of Analysis of the Association of Official Analytical Chemists (AOAC) (1). Due to mild clumping of bacterial cells at calcium equivalents of >200 ppm, this experiment was repeated by plate viability assays at 400 ppm and 800 ppm in order to determine the efficacy of PlyC in hard water.
Plate viability assays.
Stock PlyC was diluted 10-fold in sterile PBS to make working stocks ranging from 10 mg/ml (1.0% solution) to 100 ng/ml (0.00001% solution). PlyC (100 µl) at these various concentrations was mixed with 900 µl of S. equi 9528 (Smr) at a final bacterial concentration of
1 x 108 CFU/ml and incubated at 25°C for 30 min. Consequently, final PlyC concentrations ranged from 1 mg/ml (0.1%) to 10 ng/ml (0.000001%). At the end of the incubation period, reaction mixtures were serially diluted 10-fold in sterile PBS (pH 7.4), plated on blood agar plates containing 200 µg/ml streptomycin, and incubated at 37°C for residual titer determination. Identical experiments were performed with Virkon-S (Dubois Distributors), an oxidizing chemical disinfectant, in place of PlyC over the same working concentration range (i.e., 10 mg/ml to 100 ng/ml). In similar experiments, 1 µg of PlyC was mixed with 1 x 107 CFU/ml S. equi 9528 (Smr), and 100-µl aliquots were serially diluted and plated at various time points (0, 5, 10, 15, or 20 min) to determine the time course for enzyme action.
AOAC Use Dilution test.
Modified versions of the AOAC Use Dilution Methods for Testing Disinfectants (official methods 955.15 and 964.02) (3) were used to test PlyC's efficacy as a hard surface disinfectant. Briefly, a fresh overnight culture of S. equi ATCC 9528 (Smr) was adjusted to a concentration of 1 x 106 CFU/ml based on absorbance readings. Glass rods, used as penicylinders, were dipped 2 cm into the culture and allowed to air dry for 30 min. Penicylinders (n = 60) were then dipped 2 cm into a PlyC solution (50 µg/ml) and allowed to air dry for 10 min, after which they were transferred to 5 ml of sterile medium (THY supplemented with 200 µg/ml streptomycin), agitated for 10 s, transferred to another tube containing 5 ml of sterile medium, agitated a second time for 10 s, and removed. Turbidity in either tube after overnight incubation at 37°C constituted a positive result for growth.
AOAC Germicidal Spray Products Test.
A modified version of the AOAC Germicidal Spray Products Test (official method 961.02) (2) was used to test the killing ability of aerosolized PlyC on surfaces common to a horse stable. Briefly, pieces of stable equipment (Table 2) were cut into 25.4-mm by 25.4-mm coupons. Coupons were seeded with 4 x 106 CFU of S. equi 9528 (Smr) by pipette and allowed to air dry at 25°C for 30 min. PlyC (100 µg/ml) was misted 30 cm above coupons in two passes (
1 s total time) using a thin-layer chromatography reagent sprayer (Kimble/Kontes). Treated coupons were allowed to air dry for 10 min; they were then placed in 50-ml Falcon tubes with 20 ml of sterile PBS and mechanically agitated, and the supernatant was serially diluted and plated on blood agar plates containing 200 µg/ml streptomycin for enumeration of remaining streptococci.
|
View this table: [in a new window] |
TABLE 2. Disinfectant properties of aerosolized PlyC on common stable equipment
|
|
|
|---|
The specificity of PlyC toward sensitive streptococci, including S. equi, is believed to be due to a high-affinity binding domain within the enzyme for a species-associated carbohydrate covalently attached to the bacterial cell wall (11, 20). In Fig. 1, binding of a fluorescently labeled, catalytically inactivated PlyC to the S. equi 9528 (Smr) cell surface is illustrated. Significantly, labeled PlyC does not dissociate during dilution or extensive washing, underscoring its affinity for the bacterial surface. In contrast, PlyC did not label S. aureus 8325 (Fig. 1) or other bacterial species that are not lysed by PlyC (20; also data not shown).
![]() View larger version (32K): [in a new window] |
FIG. 1. PlyC affinity for S. equi cell wall. An active-site knockout (C333S) of PlyC was cross-linked with AlexaFluor-488, mixed with S. equi 9528 (Smr) or S. aureus 8325, washed three times with PBS to remove unbound PlyC label, and viewed under bright-field and fluorescent conditions at a magnification of x2,000.
|
1 x 108 CFU/ml S. equi 9528 (Smr) over a disinfectant final concentration range of 1 mg/ml (0.1% solution) to 10 ng/ml (0.000001% solution) (Fig. 2). Virkon-S was able to sterilize the streptococcal culture within 30 min at 10 mg/ml (1.0% solution) (data not shown) as well as at 1 mg/ml, which is consistent with the effective concentration found in previous reports as well as the concentration recommended by the manufacturer (16). However, at lower concentrations, the chemical disinfectant quickly lost efficacy. In contrast, PlyC at 1 µg/ml sterilized the test solution and even produced a >3 log drop in S. equi 9528 (Smr) at 100 ng/ml. Thus, PlyC was 1,000 times more effective than Virkon-S on a weight basis. However, it should be noted that the mass of PlyC is significantly larger than that of Virkon-S. Potassium peroxymonosulfate (FW 152) is the active ingredient of Virkon-S and comprises 20% of the weight, whereas PlyC is a globular protein with a mass of 114,000 Da. Thus, on a molar basis, PlyC is approximately 150,000 times more effective than a chemical disinfectant at sterilizing S. equi.
![]() View larger version (14K): [in a new window] |
FIG. 2. Disinfection efficacy of PlyC versus Virkon-S. PlyC (hatched bars) or Virkon-S (solid bars) was tested at final concentrations between 1 mg/ml (0.1%) and 10 ng/ml (0.000001%) in the presence of 1 x 108 CFU of S. equi 9528 (Smr) for 30 min at 25°C. Residual CFU were enumerated on blood agar plates containing 200 µg/ml streptomycin to evaluate disinfectant efficacy. Note, the manufacturer recommends Virkon-S to be used as a 1% solution. Error bars show standard deviations of triplicates.
|
3 log and
5 log decrease in CFU, respectively. Notably, the 0-min time point, when cells were diluted 106-fold immediately after PlyC addition, repeatedly achieved
1 log decrease in CFU compared to buffer-alone controls, possibly due to PlyC's high binding affinity for the streptococcal surface and noted resistance to dilution (Fig. 1).
![]() View larger version (8K): [in a new window] |
FIG. 3. PlyC minimal contact time for 100% disinfection. One microgram of PlyC was mixed with 1 x 107 CFU/ml of S. equi 9528 (Smr) in a final volume of 1 ml of PBS, and 100-µl aliquots were serially diluted and plated at 0, 5, 10, 15, and 20 min on blood agar plates containing 200 µg/ml streptomycin to estimate residual CFU. The control contained no PlyC. Error bars show standard deviations of triplicates.
|
As a measure of efficacy when PlyC is used as a potential spray disinfectant, a modified version of the Germicidal Spray Products Test was used to measure the ability of aerosolized PlyC to eradicate the test organism. One-inch square (25.4 mm by 25.4 mm) coupons of nylon, cotton, leather, neoprene, polyester, wood, stainless steel, or glass were seeded with 4 x 106 CFU of S. equi 9528 (Smr) and misted with a 100 µg/ml solution of PlyC for 1 s. We estimate that each coupon was exposed to approximately 20 µl of solution, or 2 µg of PlyC. This amount of enzyme was sufficient to completely eliminate S. equi 9528 (Smr) on nonporous surfaces (glass and stainless steel), medium porosity materials (neoprene and leather), and highly porous material (nylon, cotton, and polyester) (Table 2). Even with the extremely porous coupon made of weathered wood from a stable wall, PlyC achieved more than 99.9% killing of the S. equi 9528 (Smr) inoculum (
3 log drop in the number of CFU) at the tested concentration.
Effects of detergent additives or stable conditions on PlyC eradication of S. equi.
In order to mimic a stable, PlyC was tested in combination with additives or under harsh conditions that might occur in a farm setting. PlyC (0.2 µg) was mixed with 1 x 107 CFU of S. equi 9528 (Smr) in the presence of various compounds and monitored in the spectrophotometric lysis assay to elucidate percent lysis compared to controls (Fig. 4). Detergents, if they do not inactivate the disinfectant, are useful for their ability to disperse organic matter from surfaces. Assorted detergents (1% final concentration) were used with PlyC to determine if this could improve the PlyC bactericidal efficacy. Both anionic (SDS) and cationic (CTAB) detergents were found to inactivate PlyC. However, the enzyme retained full activity in zwitterionic (CHAPS) and nonionic (Triton X-100, Tween-20, and Brij 35) detergents.
![]() View larger version (13K): [in a new window] |
FIG. 4. PlyC activity in the presence of additives/contaminants. PlyC (0.2 µg) was tested in the spectrophotometric lysis assay against S. equi 9528 (Smr) in the presence of 1% detergent (SDS [anionic], CTAB [cationic], CHAPS [zwitterionic], Triton X-100, Tween-20, and Brij 35 [all nonionic]), 10 mM EDTA, distilled water, 10% organic load (fetal bovine serum), or synthetic hard water (SHW). Error bars show standard deviation of triplicates. **, 400 ppm of SHW caused clumping of bacterial cells and erroneous optical density readings (see text); ##, 800 ppm of SHW was tested by the plate viability assay for this figure, and percent lysis of the control was calculated from controls subjected to the plate viability assay (data not shown).
|
|
|
|---|
The ideal disinfectant should have the following characteristics: biocidal against all pathogens, nontoxic to livestock or human beings, environmentally safe and biodegradable, economic and easy to use, noncorrosive or nondestructive to stable surfaces, capable of being used in combination with detergents, and unaffected by organic matter or hard water. Clearly, the ideal disinfectant does not exist. However, while PlyC does not possess broad-spectrum biocidal activity common to most disinfectants, it nonetheless has most of these attributes. PlyC's mechanism of action is enzymatic and therefore does not rely on potentially toxic reactive groups utilized by chemical disinfectants. As a protein, PlyC is inherently biodegradable and noncorrosive. Due to the tight binding of the enzyme for the streptococcal surface, PlyC binds S. equi on contact and begins killing within seconds at an effective dose of
1 µg/ml, which is several orders of magnitude lower than chemical disinfectants (Fig. 2 and 3). Although PlyC and disinfectants are likewise susceptible to dilution or being washed away when applied environmentally, once PlyC comes into contact with the bacterial surface, it remains tightly bound and is not inactivated by further washing or dilution as are conventional disinfectants. The high-affinity binding of lysin for the bacterial surface, which has been measured in the nanomolar range (18), is a hallmark of this class of enzyme. Additionally, PlyC works on a variety of porous and nonporous materials common to horse stables. While PlyC and other lysins will never replace the need for broad-spectrum disinfectants, they can nonetheless complement disinfectants under conditions where control of a particular pathogen is desired.
Another important component of managing equine and other livestock facilities is the use of detergents, which ideally would be used in conjunction with disinfectants. Detergents serve to disperse and remove soil and organic material from surfaces, thereby allowing disinfectants to reach embedded, otherwise protected microbes. However, chemical disinfectants often have reduced activity (aldehydes) or are inactivated (biguanides, hypochlorites, and quaternary ammonium compounds) by detergents (8). Anionic detergents (e.g., SDS) have a negative charge and are not ideal for cleaning because of excessive foaming. Cationic detergents (e.g., CTAB), are positively charged but are seldom used as cleaning agents. Likewise, zwitterionic detergents (e.g., CHAPS), which have both positive and negative charges, are not commonly found in cleaning products. Uncharged, nonionic detergents, such as Triton X-100, Tween-20, and Brij 35, are good emulsifiers, have good penetration and dispersion, are effective at lowering surface tension, and have reduced foaming properties, making them suitable industrial detergents (8). Significantly, PlyC has full bacteriolytic activity in the presence of these nonionic detergents despite being inactivated by anionic and cationic detergents.
Additional considerations important in determining optimal disinfectant use result from metal ions in hard water, often found in well water common to rural farm settings, which can bind to either disinfectants or detergents and interfere with their effectiveness. Consequently, metal chelators such as EDTA are commonly used to complex metal ions to combat the negative effects of hard water. Organic materials such as soil and manure are also routinely encountered on a farm and could interfere with disinfectant action. Because PlyC has full bacteriolytic activity in nonionic detergents, EDTA, hard water, and in an organic load (defined by the AOAC), it is well suited for equine-related S. equi environmental disinfecting applications.
Historically, disinfectants are chemical entities. In fact, all 275 active ingredients from more than 5,000 commercially available disinfectants, sterilizers, sanitizers, antiseptics, and germicides registered and regulated by the U.S. Environmental Protection Agency (http://www.epa.gov) are chemical entities. Thus, our proposed use of an enzyme, PlyC, for disinfection/decontamination of S. equi represents a fundamental shift from convention. We attempted to validate and benchmark PlyC as a disinfectant using a standard battery of guidelines and tests developed by the AOAC and adopted by the Environmental Protection Agency (1-3). However, the intrinsic properties of PlyC made many of these guidelines difficult to follow directly. For example, most AOAC protocols call for a neutralization solution or dilution step to stop the killing actions of the disinfectant so that remaining bacterial counts can be assessed at discrete time points. Unexpectedly, we could not identify a neutralizing condition to inactivate PlyC that was not also detrimental to the test organism. For example, temperatures high enough to denature PlyC also killed S. equi (data not shown). Similarly, cysteine protease inhibitors are known to inhibit the active-site cysteine residue of PlyC (20), but at the required concentrations, these inhibitors are also lethal to S. equi (data not shown). Even attempts to wash PlyC from the surface of S. equi 9528 (Smr) failed due to tight binding of the enzyme to the bacterial cell wall, as seen in Fig. 1, and rapid dilution was likewise unsuccessful, as evidenced by the
1 log drop in the number of CFU when PlyC was immediately diluted at time zero (Fig. 3). While these difficulties underscore the suitability of PlyC as a disinfectant, they nonetheless are confounding to standardized disinfectant testing protocols. Clearly, new testing methodologies and validation criteria will be needed to establish the efficacy of narrow-range, enzyme-based disinfectants.
We have presented here the potential use of PlyC as a narrow-spectrum disinfectant against S. equi subsp. equi. Full-scale testing on farms where equine strangles is endemic as well as formulation and stability studies in combination with conventional disinfectants will be required to validate future development of PlyC. Although the current testing was limited to S. equi subsp. equi, it should be noted that there are a number of other group C streptococci of veterinary importance that are likewise sensitive to PlyC. S. dysgalactiae has been shown to cause bovine mastitis in milking cows (28) as well as polyarthritis in goats (5), and S. equi subsp. zooepidemicus is a pathogen to pigs, cows, and horses (4). Beyond PlyC, there are also a number of other settings where a safe, environmentally friendly, narrow-spectrum disinfectant with near-species specificity could drastically reduce disease transmission. For example, disinfectants targeting methicillin-resistant S. aureus may be practical in surgical suites, nursing homes, or gymnasiums; those against Listeria monocytogenes would have applications in food-processing facilities; reduction of S. pyogenes or S. pneumoniae bacterial loads in day care settings or areas of dense living quarters (i.e., military barracks) could address cases of bacterial pharyngitis or otitis media, respectively; and additional methods for decontaminating suspected exposures of Bacillus anthracis remain a security priority. Notably, bacteriophage-derived lysins that can address all of these organisms have been cloned, expressed, and biochemically studied (13, 17-19, 22, 23). Further development of these lysins for environmental use as narrow-spectrum disinfectants could provide important alternatives to curtail the acquisition and spread of important pathogens.
We thank Timothy P. Trayer, Randy Shirbroun, and John F. Timoney for clinical isolates of S. equi and Vincent A. Fischetti for other bacterial strains.
The mention of trade names is merely for the sake of completeness for repeating the experiment. There is no intended support of any product or organization through the use of these trade names.
Published ahead of print on 9 January 2009. ![]()
|
|
|---|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»