This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bukhari, Z.
Right arrow Articles by Clancy, J. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bukhari, Z.
Right arrow Articles by Clancy, J. L.
Agricola
Right arrow Articles by Bukhari, Z.
Right arrow Articles by Clancy, J. L.

 Previous Article  |  Next Article 

Applied and Environmental Microbiology, November 1998, p. 4495-4499, Vol. 64, No. 11
0099-2240/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.

Immunomagnetic Separation of Cryptosporidium parvum from Source Water Samples of Various Turbidities

Z. Bukhari,1,* R. M. McCuin,1 C. R. Fricker,2 and J. L. Clancy1

Clancy Environmental Consultants, St. Albans, Vermont 05478,1 and Thames Water Utilities, Reading, United Kingdom2

Received 13 April 1998/Accepted 7 August 1998

Immunomagnetic separation (IMS) procedures which specifically capture Cryptosporidium oocysts and have the potential to isolate oocysts from debris have become commercially available. We compared two IMS kits (kit DB [Dynabeads anti-Cryptosporidium; product no. 730.01; Dynal A.S., Oslo, Norway] and kit IC1 [Crypto Scan IMS; product no. R10; Clearwater Diagnostics Company, LLC, Portland, Maine]) and a modification of kit IC1 (kit IC2 [Crypto Scan IMS; product no. R10; Clearwater Diagnostics Company, LLC]) at three turbidity levels (50, 500, and 5,000 nephelometric turbidity units [ntu]) by using water matrices obtained from different geographical locations. In deionized water, kit DB yielded recoveries between 68 and 83%, whereas the recoveries obtained with kits IC1 and IC2 were more variable and ranged from 0.2 to 74.5%. In water matrices with turbidity levels up to 500 ntu, the oocyst recoveries were more variable with kit DB; however, the recoveries were similar to those obtained in deionized water. In contrast, there were notable reductions in oocyst recoveries in the turbid matrices with kits IC1 and IC2, and the highest recovery (8.3%) was obtained with a 50-ntu sample. An examination of the effects of age on oocyst recovery with kit DB revealed that oocysts up to 16 weeks old yielded recoveries similar to the recoveries observed with fresh oocysts. These data indicate that all IMS kits do not perform equally well, and it is important to conduct in-house quality assurance work before a commercially available IMS kit is selected to replace flotation procedures for recovery of Cryptosporidium oocysts.


* Corresponding author. Mailing address: Clancy Environmental Consultants, Inc., 272 North Main St., P.O. Box 314, St. Albans, VT 05478. Phone: (802) 527-2460. Fax: (802) 524-3909. E-mail: zbukhari{at}together.net.


Applied and Environmental Microbiology, November 1998, p. 4495-4499, Vol. 64, No. 11
0099-2240/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.



This article has been cited by other articles:

  • Lim, D. V., Simpson, J. M., Kearns, E. A., Kramer, M. F. (2005). Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare. Clin. Microbiol. Rev. 18: 583-607 [Abstract] [Full Text]  
  • Jiang, J., Alderisio, K. A., Singh, A., Xiao, L. (2005). Development of Procedures for Direct Extraction of Cryptosporidium DNA from Water Concentrates and for Relief of PCR Inhibitors. Appl. Environ. Microbiol. 71: 1135-1141 [Abstract] [Full Text]  
  • Ochiai, Y., Takada, C., Hosaka, M. (2005). Detection and Discrimination of Cryptosporidium parvum and C. hominis in Water Samples by Immunomagnetic Separation-PCR. Appl. Environ. Microbiol. 71: 898-903 [Abstract] [Full Text]  
  • Villena, I., Aubert, D., Gomis, P., Ferte, H., Inglard, J.-C., Denis-Bisiaux, H., Dondon, J.-M., Pisano, E., Ortis, N., Pinon, J.-M. (2004). Evaluation of a Strategy for Toxoplasma gondii Oocyst Detection in Water. Appl. Environ. Microbiol. 70: 4035-4039 [Abstract] [Full Text]  
  • Francy, D. S., Simmons, O. D. III, Ware, M. W., Granger, E. J., Sobsey, M. D., Schaefer, F. W. III (2004). Effects of Seeding Procedures and Water Quality on Recovery of Cryptosporidium Oocysts from Stream Water by Using U.S. Environmental Protection Agency Method 1623. Appl. Environ. Microbiol. 70: 4118-4128 [Abstract] [Full Text]  
  • Morales-Morales, H. A., Vidal, G., Olszewski, J., Rock, C. M., Dasgupta, D., Oshima, K. H., Smith, G. B. (2003). Optimization of a Reusable Hollow-Fiber Ultrafilter for Simultaneous Concentration of Enteric Bacteria, Protozoa, and Viruses from Water. Appl. Environ. Microbiol. 69: 4098-4102 [Abstract] [Full Text]  
  • Feng, Y. Y., Ong, S. L., Hu, J. Y., Song, L. F., Tan, X. L., Ng, W. J. (2003). Effect of Particles on the Recovery of Cryptosporidium Oocysts from Source Water Samples of Various Turbidities. Appl. Environ. Microbiol. 69: 1898-1903 [Abstract] [Full Text]  
  • McCuin, R. M., Clancy, J. L. (2003). Modifications to United States Environmental Protection Agency Methods 1622 and 1623 for Detection of Cryptosporidium Oocysts and Giardia Cysts in Water. Appl. Environ. Microbiol. 69: 267-274 [Abstract] [Full Text]  
  • Dai, X., Boll, J. (2003). Evaluation of Attachment of Cryptosporidium parvum and Giardia lamblia to Soil Particles. J. Environ. Qual. 32: 296-304 [Abstract] [Full Text]  
  • DiGiorgio, C. L., Gonzalez, D. A., Huitt, C. C. (2002). Cryptosporidium and Giardia Recoveries in Natural Waters by Using Environmental Protection Agency Method 1623. Appl. Environ. Microbiol. 68: 5952-5955 [Abstract] [Full Text]  
  • Sturbaum, G. D., Klonicki, P. T., Marshall, M. M., Jost, B. H., Clay, B. L., Sterling, C. R. (2002). Immunomagnetic Separation (IMS)-Fluorescent Antibody Detection and IMS-PCR Detection of Seeded Cryptosporidium parvum Oocysts in Natural Waters and Their Limitations. Appl. Environ. Microbiol. 68: 2991-2996 [Abstract] [Full Text]  
  • Kuhn, R. C., Rock, C. M., Oshima, K. H. (2002). Effects of pH and Magnetic Material on Immunomagnetic Separation of Cryptosporidium Oocysts from Concentrated Water Samples. Appl. Environ. Microbiol. 68: 2066-2070 [Abstract] [Full Text]  
  • Ono, K., Tsuji, H., Rai, S. K., Yamamoto, A., Masuda, K., Endo, T., Hotta, H., Kawamura, T., Uga, S. (2001). Contamination of River Water by Cryptosporidium parvum Oocysts in Western Japan. Appl. Environ. Microbiol. 67: 3832-3836 [Abstract] [Full Text]  
  • Sturbaum, G. D., Reed, C., Hoover, P. J., Jost, B. H., Marshall, M. M., Sterling, C. R. (2001). Species-Specific, Nested PCR-Restriction Fragment Length Polymorphism Detection of Single Cryptosporidium parvum Oocysts. Appl. Environ. Microbiol. 67: 2665-2668 [Abstract] [Full Text]  
  • Simmons, O. D. III, Sobsey, M. D., Heaney, C. D., Schaefer, F. W. III, Francy, D. S. (2001). Concentration and Detection of Cryptosporidium Oocysts in Surface Water Samples by Method 1622 Using Ultrafiltration and Capsule Filtration. Appl. Environ. Microbiol. 67: 1123-1127 [Abstract] [Full Text]  
  • Weir, C., Vesey, G., Slade, M., Ferrari, B., Veal, D. A., Williams, K. (2000). An Immunoglobulin G1 Monoclonal Antibody Highly Specific to the Wall of Cryptosporidium Oocysts. CVI 7: 745-750 [Abstract] [Full Text]  
  • Yakub, G. P., Stadterman-Knauer, K. L. (2000). Evaluation of Immunomagnetic Separation for Recovery of Cryptosporidium parvum and Giardia duodenalis from High-Iron Matrices. Appl. Environ. Microbiol. 66: 3628-3631 [Abstract] [Full Text]  
  • Di Giovanni, G. D., Hashemi, F. H., Shaw, N. J., Abrams, F. A., LeChevallier, M. W., Abbaszadegan, M. (1999). Detection of Infectious Cryptosporidium parvum Oocysts in Surface and Filter Backwash Water Samples by Immunomagnetic Separation and Integrated Cell Culture-PCR. Appl. Environ. Microbiol. 65: 3427-3432 [Abstract] [Full Text]  
  • Pereira, M. d. G. C., Atwill, E. R., Jones, T. (1999). Comparison of Sensitivity of Immunofluorescent Microscopy to That of a Combination of Immunofluorescent Microscopy and Immunomagnetic Separation for Detection of Cryptosporidium parvum Oocysts in Adult Bovine Feces. Appl. Environ. Microbiol. 65: 3236-3239 [Abstract] [Full Text]