Previous Article | Next Article ![]()
Applied and Environmental Microbiology, October 2002, p. 5198-5201, Vol. 68, No. 10
0099-2240/02/$04.00+0 DOI: 10.1128/AEM.68.10.5198-5201.2002
Copyright © 2002, American Society for Microbiology. All Rights Reserved.
Scottish Parasite Diagnostic Laboratory, Stobhill Hospital, Glasgow G21 3UW, Scotland, United Kingdom
Received 15 May 2001/ Accepted 17 May 2002
Of 2,361 water concentrates analyzed for the presence of Cryptosporidium spp. oocysts between January 1992 and May 1998, 269 (11.4%) were positive, of which 235 (87.4%) were raw and 34 were final water concentrates. Of 740 oocysts enumerated in positive samples, 656 oocysts (88.7%) were detected in raw and 84 oocysts (11.3%) were detected in final water concentrates by using a commercially available fluorescein isothiocyanate-labeled anti-Cryptosporidium sp. monoclonal antibody and the nuclear fluorogen 4',6'-diamidino-2-phenylindole (DAPI). Of raw water positive samples, 66.8% had oocysts that contained nuclei, while 58.8% of final water samples had oocysts that contained nuclei. The most frequently identified oocysts had either no DAPI-positive nuclei and no internal morphology according to Nomarski differential interference-contrast microscopy (DIC) or four DAPI-positive nuclei together with internal contents according to DIC (39.5 and 32.8% of raw and 42.9 and 30.9% of final water positives, respectively). By use of the presence of DAPI-stained nuclei to support oocyst identification based upon oocyst wall fluorescence, 56.5% of oocysts were identified when at least one nucleus was present, while increasing the number of nuclei necessary for identification to four reduced the percentage identifiable to 32.8% in raw water concentrates. In final water concentrates, 51% of oocysts were identified using oocyst wall fluorescence and the presence of at least one nucleus, while increasing the number of nuclei necessary for identification to four reduced the percentage identifiable to 30.9%. By consolidating our identification criteria from the presence of at least one nucleus to the presence of four nuclei, we excluded approximately 20% of oocysts in either water type. Approximately 40% of oocysts detected in these United Kingdom samples were empty and could not be detected by alternative methods, including the PCR and fluorescence in situ hybridization.
This article has been cited by other articles:
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»