This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pope, M. L.
Right arrow Articles by Standridge, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pope, M. L.
Right arrow Articles by Standridge, J.
Agricola
Right arrow Articles by Pope, M. L.
Right arrow Articles by Standridge, J.

 Previous Article  |  Next Article 

Applied and Environmental Microbiology, October 2003, p. 6201-6207, Vol. 69, No. 10
0099-2240/03/$08.00+0     DOI: 10.1128/AEM.69.10.6201-6207.2003
Copyright © 2003, American Society for Microbiology. All Rights Reserved.

Assessment of the Effects of Holding Time and Temperature on Escherichia coli Densities in Surface Water Samples

Misty L. Pope,1* Michelle Bussen,2 Mary Ann Feige,3 Lois Shadix,3 Sharon Gonder,4 Crystal Rodgers,4 Yildiz Chambers,1 Jessica Pulz,1 Ken Miller,1 Kevin Connell,1 and Jon Standridge2

DynCorp, Alexandria, Virginia 22304,1 Wisconsin State Laboratory of Hygiene, Madison, Wisconsin 53718,2 Environmental Protection Agency Technical Support Center, Cincinnati, Ohio 45268-1320,3 Environmental Protection Agency Headquarters, Washington, D.C. 204604

Received 28 February 2003/ Accepted 1 July 2003

Escherichia coli is a routinely used microbiological indicator of water quality. To determine whether holding time and storage conditions had an effect on E. coli densities in surface water, studies were conducted in three phases, encompassing 24 sites across the United States and four commonly used monitoring methods. During all three phases of the study, E. coli samples were analyzed at time 0 and at 8, 24, 30, and 48 h after sample collection. During phase 1, when 4°C samples were evaluated by Colilert or by placing a membrane onto mFC medium followed by transfer to nutrient agar containing 4-methylumbelliferyl-ß-D-glucuronide (mFC/NA-MUG), three of four sites showed no significant differences throughout the 48-h study. During phase 2, five of seven sites showed no significant difference between time 0 and 24 h by membrane filtration (mFC/NA-MUG). When evaluated by the Colilert method, five of seven sites showed no significant difference in E. coli density between time 0 and 48 h. During phase 3, 8 of 13 sites showed no significant differences in E. coli densities between time 0 and the 48-h holding time, regardless of method. Based on the results of these studies, it appears that if samples are held below 10°C and are not allowed to freeze, most surface water E. coli samples analyzed by commonly used methods beyond 8 h after sample collection can generate E. coli data comparable to those generated within 8 h of sample collection. Notwithstanding this conclusion, E. coli samples collected from surface waters should always be analyzed as soon as possible.


* Corresponding author. Mailing address: DynCorp, 6101 Stevenson Ave., Alexandria, VA 22304. Phone: (703) 461-2127. Fax: (703) 461-8056. E-mail: Misty.Pope{at}dyncorp.com.


Applied and Environmental Microbiology, October 2003, p. 6201-6207, Vol. 69, No. 10