This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Spaan, S.
Right arrow Articles by Wouters, I. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Spaan, S.
Right arrow Articles by Wouters, I. M.
Agricola
Right arrow Articles by Spaan, S.
Right arrow Articles by Wouters, I. M.

 Previous Article  |  Next Article 

Applied and Environmental Microbiology, June 2008, p. 3804-3811, Vol. 74, No. 12
0099-2240/08/$08.00+0     doi:10.1128/AEM.02537-07
Copyright © 2008, American Society for Microbiology. All Rights Reserved.

Effect of Extraction and Assay Media on Analysis of Airborne Endotoxin{triangledown}

Suzanne Spaan,1,2 Gert Doekes,1 Dick Heederik,1 Peter S. Thorne,3 and Inge M. Wouters1*

Institute for Risk Assessment Sciences (IRAS), Environmental Epidemiology Division (EEPI), Utrecht University, Utrecht, The Netherlands,1 Quality and Safety Business Unit, Food and Chemical Risk Analysis Division, TNO Quality of Life, Zeist, The Netherlands,2 Environmental Health Sciences Research Center, University of Iowa, Iowa City, Iowa3

Received 10 November 2007/ Accepted 18 April 2008

The measurement of airborne endotoxins is thus far not standardized. Earlier studies reported higher endotoxin yields when Tween 20 was added to the media used for filter extraction and in the Limulus amebocyte lysate (LAL) assay. This study compared four common media and assessed the effects of Tween during extraction and analysis separately. Parallel airborne dust samples from five work environments (n = 250) were used to compare the four media (pyrogen-free water [PFW], PFW-Tween 20, PFW-Tris, and PFW-triethylamine-phosphate [TAP]) and an extraction time of 10 or 60 min. A subset of the extracts in PFW or PFW-Tween (n = 40) were analyzed in parallel LAL assays with PFW or PFW-Tween as the assay medium. The results produced by a shorter extraction time or the presence of Tris were similar to the results for the reference procedure (PFW and 60 min of shaking). The use of PFW-TAP showed overall lower yields and a deviant calibration curve. The presence of Tween in the extraction medium resulted in significantly (P < 0.05) higher endotoxin yields from all dust types, independent of the effect of Tween in the assay. Tween in the LAL assay, however, also strongly inhibited the reactivity of the lipopolysaccharide (LPS) standard, thus shifting the calibration curve to higher values. The inhibition of LPS in test samples was less pronounced and varied between dust sources, resulting in enhanced calculated concentrations. This assay effect could be circumvented by diluting extracts at least 50-fold before the LAL assay. In conclusion, of the media tested, only Tween enhances the efficiency of endotoxin extraction from airborne dust samples in a consistent manner. We recommend extraction in PFW-Tween combined with dilution and LAL analysis in PFW.


* Corresponding author. Mailing address: Institute for Risk Assessment Sciences, Environmental Epidemiology Division, Utrecht University, P.O. Box 80178, 3508 TD Utrecht, The Netherlands. Phone: 31 30 253 9449. Fax: 31 30 253 9499. E-mail: I.Wouters{at}uu.nl

{triangledown} Published ahead of print on 25 April 2008.


Applied and Environmental Microbiology, June 2008, p. 3804-3811, Vol. 74, No. 12
0099-2240/08/$08.00+0     doi:10.1128/AEM.02537-07
Copyright © 2008, American Society for Microbiology. All Rights Reserved.