TABLE 2.

Mean values and sigma for HAdV and JCPyV GC in the different wastewater matrices analyzeda

Type of sample analyzedHAdV assay 1HAdV assay 2JCPyV
Mean valueSigmaMean valueSigmaMean valueSigma
Sewage (ml)3.87 × 1043.78 × 1031.79 × 1044.58 × 1036.11 × 1032.58 × 103
Effluent (ml)b4.694.693.19 × 1000.950.630.28
Sludge (g [dry wt])1.83 × 1028.64 × 1015.50 × 1012.36 × 1012.35 × 1021.02 × 102
Biosolid (g [dry wt])1.59 × 1042.24 × 1045.19 × 1021.89 × 1028.05 × 1025.94 × 102
  • a Sigma is the repeatability error for any individual measure and consists of the square root of the mean square error of the one-way ANOVA. Results are expressed as GC/ml for wastewater or GC/g of dry weight for sludge and biosolids.